Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Ablación combinada de campo pulsado (PFA) y oclusión del apéndice auricular izquierdo con Watchman Flx o Amulet (COMPAWA)

16 de noviembre de 2026 actualizado por: Dr So Chak Yu kent, Prince of Wales Hospital, Shatin, Hong Kong

Ablación combinada de campo pulsado (PFA) y oclusión del apéndice auricular izquierdo con Watchman Flx o Amulet: un estudio controlado aleatorizado

AF ablation is an established treatment option for non-valvular atrial fibrillation (NVAF). While AF ablation helps to maintain cardiac rhythm in sinus, the stroke risk associated with AF persists after ablation. Oral anticoagulant (OAC) therapy is currently the standard therapy before and after successful ablation. Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC. As both AF ablation and percutaneous LAAO require transseptal access from to left atrium, combining the two procedures into one single procedure may provide a straightforward strategy aiming at concomitant rhythm control as well as stroke prevention, without the additional risk of multiple procedures. It is showed in previous studies that this approach is feasible and safe.

Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation. Irreversible electroporation is the application of high electric field to a cell with a resultant increased permeability of the membrane and downstream cell death. Success with PFA depends upon the proximity of the electrode to the target tissue, but not necessarily upon contact. Therefore, with PFA the transseptal access for successful AF ablation is less demanding. Moreover, PFA would induce less pulmonary ridge edema compared to conventional ablation techniques and could potentially causes less PDL. Watchman Flx Pro(Boston Scientific) and Amulet (Abbott) are the two most commonly used LAAO devices. The two devices have different designs, deployment requirements and occlusion results. Both devices have been used in combined procedure. However, there is no data of combined AF ablation and LAAO using the PFA technique, and of combined AF ablation comparing the use of Watchman Flx versus Amulet device.

In this randomized controlled study, we aim to assess the feasibility and compare the peri-procedural outcomes and LAA occlusion result of combined AF ablation (using the PFA technique), and LAAO using either the Watchman Flx Pro or the Amulet device.

Descripción general del estudio

Descripción detallada

Atrial fibrillation (AF) is the most common cardiac arrythmia globally. Its prevalence ranges between 2-4% worldwide. It is associated with significant morbidity and mortality. AF ablation is an established treatment option for non-valvular atrial fibrillation (NVAF). While AF ablation helps to maintain cardiac rhythm in sinus, the stroke risk associated with AF persists after ablation. Oral anticoagulant (OAC) therapy is currently the standard therapy before and after successful ablation. Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC . As both AF ablation and percutaneous LAAO require transseptal access from to left atrium, combining the two procedures into one single procedure may provide a straightforward strategy aiming at concomitant rhythm control as well as stroke prevention, without the additional risk of multiple procedures. It is showed in previous studies that this approach is feasible and safe. However, the current AF ablation techniques (radiofrequency ablation and cryoballoon ablation) requires a less posterior transseptal access while LAAO requires a posterior-inferior transseptal access. This could potentially make LAAO after same procedure AF ablation using the same transseptal access more challenging. Besides, current ablation techniques would induce edema over pulmonary ridge, which could potentially result in significant peri-device leak (PDL) post LAAO after edema subsided. Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation. Irreversible electroporation is the application of high electric field to a cell with a resultant increased permeability of the membrane and downstream cell death. Success with PFA depends upon the proximity of the electrode to the target tissue, but not necessarily upon contact. Therefore, with PFA the transseptal access for successful AF ablation is less demanding. Moreover, PFA would induce less pulmonary ridge edema compared to conventional ablation techniques and could potentially causes less PDL. Watchman Flx Pro (Boston Scientific) and Amulet (Abbott) are the two most commonly used LAAO devices. The two devices have different designs, deployment requirements and occlusion results. Both devices have been used in combined procedure. However, there is no data of combined AF ablation and LAAO using the PFA technique, and of combined AF ablation comparing the use of Watchman Flx Pro versus Amulet device. In this randomized controlled study, we aim to assess the feasibility and compare the peri-procedural outcomes and LAA occlusion result of combined AF ablation (using the PFA technique), and LAAO using either the Watchman Flx Pro or the Amulet device.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

200

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Kowloon
      • Jordon, Kowloon, Hong Kong
        • Queen Elizabeth Hopsital
    • Shatin
      • Hong Kong, Shatin, Hong Kong, 0000
        • Prince of Wales Hospital
    • Macau
      • Taipa, Macau, Macao
        • Kiang Wu Hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

19 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  1. Paroxysmal or persistent non- valvular atrial fibrillation
  2. CHADS2-VASc >=1
  3. Age >=18; and able to give written consent

Exclusion Criteria:

  1. are in permanent atrial fibrillation
  2. are not eligible for 3 months of oral anticoagulant post ablation
  3. has left Atrial thrombus identified by pre-procedure TEE or during procedure
  4. had received prior left atrial appendage closure procedure (percutaneous or surgical)
  5. are planned to receive concomitant ablation procedure or structural heart interventions other than AF ablation and LAAO (e.g SVT ablation, Aflutter ablation, PFO closure, leadless pacemaker, ASD Closure, etc)
  6. patient whom refused or cannot tolerate procedural or post procedural follow-up TEE

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Comparador activo: Watchman Flx Pro

Watchman Flx Pro device to be used for LAAO

Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation

Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC

Comparador activo: Amulet

Amulet device to be used for LAAO

Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation

Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Rate of >=moderate peri-device leak (i.e. >=3mm) on follow-up TEE
Periodo de tiempo: 45-90 days

Rate of >=moderate peri-device leak (i.e. >=3mm) on follow-up TEE

45-90 days

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
LAAO technical success rate
Periodo de tiempo: Intra-operation

successful device implantation without device related complication and peri-device leak >5mm

Intra-operation
Rate of procedural related complications
Periodo de tiempo: During in-patient period of Study procedure

stroke, pericardial effusion, device embolization, mortality

During in-patient period of Study procedure
Total ablation time
Periodo de tiempo: Intra-operation

Total ablation time

Intra-operation
LAAO procedural time
Periodo de tiempo: Intra-operation

LAAO procedural time

Intra-operation
Need of additional transseptal puncture for LAAO
Periodo de tiempo: Intra-operation

Need of additional transseptal puncture for LAAO

Intra-operation
Number of device recapture (full or partial)
Periodo de tiempo: Intra-operation

Number of device recapture (full or partial)

Intra-operation
Number of device used
Periodo de tiempo: Intra-operation

Number of device used

Intra-operation
PFA acute technical success
Periodo de tiempo: Intra-operation

electric isolation of 4 pulmonary veins) by pre-ablation and post ablation mapping

Intra-operation
AF ablation procedural success
Periodo de tiempo: Intra-operation

AF ablation procedural success, defined as no ECG, holter, or rhythm strip documentation of recurrence of AF, AT, Aflutter lasting more than 30 seconds at 1 year

Intra-operation
Number of Participants with 1-year clinical events
Periodo de tiempo: 12-months

bleeding or thromboembolic event

12-months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Investigador principal: Chak YU So, MBChB, Prince of Wales Hospital, Shatin, Hong Kong

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Publicaciones Generales

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

1 de enero de 2023

Finalización primaria (Estimado)

31 de diciembre de 2027

Finalización del estudio (Estimado)

28 de abril de 2028

Fechas de registro del estudio

Enviado por primera vez

26 de septiembre de 2022

Primero enviado que cumplió con los criterios de control de calidad

26 de septiembre de 2022

Publicado por primera vez (Actual)

29 de septiembre de 2022

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

19 de noviembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

16 de noviembre de 2026

Última verificación

1 de noviembre de 2026

Más información

Términos relacionados con este estudio

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

Sí

producto fabricado y exportado desde los EE. UU.

Sí

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir