- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT05560204
Połączona ablacja polem pulsacyjnym (PFA) i niedrożność uszka lewego przedsionka za pomocą Watchman Flx lub Amulet (COMPAWA)
Połączona ablacja pola pulsacyjnego (PFA) i niedrożność uszka lewego przedsionka za pomocą Watchman Flx lub Amulet: randomizowane badanie kontrolowane
AF ablation is an established treatment option for non-valvular atrial fibrillation (NVAF). While AF ablation helps to maintain cardiac rhythm in sinus, the stroke risk associated with AF persists after ablation. Oral anticoagulant (OAC) therapy is currently the standard therapy before and after successful ablation. Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC. As both AF ablation and percutaneous LAAO require transseptal access from to left atrium, combining the two procedures into one single procedure may provide a straightforward strategy aiming at concomitant rhythm control as well as stroke prevention, without the additional risk of multiple procedures. It is showed in previous studies that this approach is feasible and safe.
Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation. Irreversible electroporation is the application of high electric field to a cell with a resultant increased permeability of the membrane and downstream cell death. Success with PFA depends upon the proximity of the electrode to the target tissue, but not necessarily upon contact. Therefore, with PFA the transseptal access for successful AF ablation is less demanding. Moreover, PFA would induce less pulmonary ridge edema compared to conventional ablation techniques and could potentially causes less PDL. Watchman Flx Pro(Boston Scientific) and Amulet (Abbott) are the two most commonly used LAAO devices. The two devices have different designs, deployment requirements and occlusion results. Both devices have been used in combined procedure. However, there is no data of combined AF ablation and LAAO using the PFA technique, and of combined AF ablation comparing the use of Watchman Flx versus Amulet device.
In this randomized controlled study, we aim to assess the feasibility and compare the peri-procedural outcomes and LAA occlusion result of combined AF ablation (using the PFA technique), and LAAO using either the Watchman Flx Pro or the Amulet device.
Przegląd badań
Status
Interwencja / Leczenie
Szczegółowy opis
Atrial fibrillation (AF) is the most common cardiac arrythmia globally. Its prevalence ranges between 2-4% worldwide. It is associated with significant morbidity and mortality. AF ablation is an established treatment option for non-valvular atrial fibrillation (NVAF). While AF ablation helps to maintain cardiac rhythm in sinus, the stroke risk associated with AF persists after ablation. Oral anticoagulant (OAC) therapy is currently the standard therapy before and after successful ablation. Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC . As both AF ablation and percutaneous LAAO require transseptal access from to left atrium, combining the two procedures into one single procedure may provide a straightforward strategy aiming at concomitant rhythm control as well as stroke prevention, without the additional risk of multiple procedures. It is showed in previous studies that this approach is feasible and safe. However, the current AF ablation techniques (radiofrequency ablation and cryoballoon ablation) requires a less posterior transseptal access while LAAO requires a posterior-inferior transseptal access. This could potentially make LAAO after same procedure AF ablation using the same transseptal access more challenging. Besides, current ablation techniques would induce edema over pulmonary ridge, which could potentially result in significant peri-device leak (PDL) post LAAO after edema subsided. Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation. Irreversible electroporation is the application of high electric field to a cell with a resultant increased permeability of the membrane and downstream cell death. Success with PFA depends upon the proximity of the electrode to the target tissue, but not necessarily upon contact. Therefore, with PFA the transseptal access for successful AF ablation is less demanding. Moreover, PFA would induce less pulmonary ridge edema compared to conventional ablation techniques and could potentially causes less PDL. Watchman Flx Pro (Boston Scientific) and Amulet (Abbott) are the two most commonly used LAAO devices. The two devices have different designs, deployment requirements and occlusion results. Both devices have been used in combined procedure. However, there is no data of combined AF ablation and LAAO using the PFA technique, and of combined AF ablation comparing the use of Watchman Flx Pro versus Amulet device. In this randomized controlled study, we aim to assess the feasibility and compare the peri-procedural outcomes and LAA occlusion result of combined AF ablation (using the PFA technique), and LAAO using either the Watchman Flx Pro or the Amulet device.
Typ studiów
Zapisy (Szacowany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Paroxysmal or persistent non- valvular atrial fibrillation
- CHADS2-VASc >=1
- Age >=18; and able to give written consent
Exclusion Criteria:
- are in permanent atrial fibrillation
- are not eligible for 3 months of oral anticoagulant post ablation
- has left Atrial thrombus identified by pre-procedure TEE or during procedure
- had received prior left atrial appendage closure procedure (percutaneous or surgical)
- are planned to receive concomitant ablation procedure or structural heart interventions other than AF ablation and LAAO (e.g SVT ablation, Aflutter ablation, PFO closure, leadless pacemaker, ASD Closure, etc)
- patient whom refused or cannot tolerate procedural or post procedural follow-up TEE
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Aktywny komparator: Watchman Flx Pro
Watchman Flx Pro device to be used for LAAO |
Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC |
|
Aktywny komparator: Amulet
Amulet device to be used for LAAO |
Pulsed-field ablation (PFA) is a non-thermal ablation technology that uses high amplitude pulsed electrical fields to ablate tissues through the mechanism of irreversible electroporation Percutaneous LAA Occlusion (LAAO) has been emerged as an alternative to oral anticoagulants for stroke prophylaxis in patients who refused or contraindicated to OAC |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Rate of >=moderate peri-device leak (i.e. >=3mm) on follow-up TEE
Ramy czasowe: 45-90 days
|
Rate of >=moderate peri-device leak (i.e. >=3mm) on follow-up TEE |
45-90 days
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
LAAO technical success rate
Ramy czasowe: Intra-operation
|
successful device implantation without device related complication and peri-device leak >5mm |
Intra-operation
|
|
Rate of procedural related complications
Ramy czasowe: During in-patient period of Study procedure
|
stroke, pericardial effusion, device embolization, mortality |
During in-patient period of Study procedure
|
|
Total ablation time
Ramy czasowe: Intra-operation
|
Total ablation time |
Intra-operation
|
|
LAAO procedural time
Ramy czasowe: Intra-operation
|
LAAO procedural time |
Intra-operation
|
|
Need of additional transseptal puncture for LAAO
Ramy czasowe: Intra-operation
|
Need of additional transseptal puncture for LAAO |
Intra-operation
|
|
Number of device recapture (full or partial)
Ramy czasowe: Intra-operation
|
Number of device recapture (full or partial) |
Intra-operation
|
|
Number of device used
Ramy czasowe: Intra-operation
|
Number of device used |
Intra-operation
|
|
PFA acute technical success
Ramy czasowe: Intra-operation
|
electric isolation of 4 pulmonary veins) by pre-ablation and post ablation mapping |
Intra-operation
|
|
AF ablation procedural success
Ramy czasowe: Intra-operation
|
AF ablation procedural success, defined as no ECG, holter, or rhythm strip documentation of recurrence of AF, AT, Aflutter lasting more than 30 seconds at 1 year |
Intra-operation
|
|
Number of Participants with 1-year clinical events
Ramy czasowe: 12-months
|
bleeding or thromboembolic event |
12-months
|
Współpracownicy i badacze
Śledczy
- Główny śledczy: Chak YU So, MBChB, Prince of Wales Hospital, Shatin, Hong Kong
Publikacje i pomocne linki
Publikacje ogólne
- Phillips KP, Walker DT, Humphries JA. Combined catheter ablation for atrial fibrillation and Watchman(R) left atrial appendage occlusion procedures: Five-year experience. J Arrhythm. 2016 Apr;32(2):119-26. doi: 10.1016/j.joa.2015.11.001. Epub 2015 Dec 8.
- Swaans MJ, Alipour A, Rensing BJ, Post MC, Boersma LV. Catheter ablation in combination with left atrial appendage closure for atrial fibrillation. J Vis Exp. 2013 Feb 26;(72):e3818. doi: 10.3791/3818.
- Alipour A, Swaans MJ, van Dijk VF, Balt JC, Post MC, Bosschaert MAR, Rensing BJ, Reddy VY, Boersma LVA. Ablation for Atrial Fibrillation Combined With Left Atrial Appendage Closure. JACC Clin Electrophysiol. 2015 Dec;1(6):486-495. doi: 10.1016/j.jacep.2015.07.009. Epub 2015 Oct 22.
- Calvo N, Salterain N, Arguedas H, Macias A, Esteban A, Garcia de Yebenes M, Gavira JJ, Barba J, Garcia-Bolao I. Combined catheter ablation and left atrial appendage closure as a hybrid procedure for the treatment of atrial fibrillation. Europace. 2015 Oct;17(10):1533-40. doi: 10.1093/europace/euv070. Epub 2015 May 1.
- Fassini G, Conti S, Moltrasio M, Maltagliati A, Tundo F, Riva S, Dello Russo A, Casella M, Majocchi B, Zucchetti M, Russo E, Marino V, Pepi M, Tondo C. Concomitant cryoballoon ablation and percutaneous closure of left atrial appendage in patients with atrial fibrillation. Europace. 2016 Nov;18(11):1705-1710. doi: 10.1093/europace/euw007. Epub 2016 Jul 11.
- Phillips KP, Pokushalov E, Romanov A, Artemenko S, Folkeringa RJ, Szili-Torok T, Senatore G, Stein KM, Razali O, Gordon N, Boersma LVA. Combining Watchman left atrial appendage closure and catheter ablation for atrial fibrillation: multicentre registry results of feasibility and safety during implant and 30 days follow-up. Europace. 2018 Jun 1;20(6):949-955. doi: 10.1093/europace/eux183.
- He B, Jiang LS, Hao ZY, Wang H, Miao YT. Combination of ablation and left atrial appendage closure as "One-stop" procedure in the treatment of atrial fibrillation: Current status and future perspective. Pacing Clin Electrophysiol. 2021 Jul;44(7):1259-1266. doi: 10.1111/pace.14201. Epub 2021 Mar 9.
- Reddy VY, Dukkipati SR, Neuzil P, Anic A, Petru J, Funasako M, Cochet H, Minami K, Breskovic T, Sikiric I, Sediva L, Chovanec M, Koruth J, Jais P. Pulsed Field Ablation of Paroxysmal Atrial Fibrillation: 1-Year Outcomes of IMPULSE, PEFCAT, and PEFCAT II. JACC Clin Electrophysiol. 2021 May;7(5):614-627. doi: 10.1016/j.jacep.2021.02.014. Epub 2021 Apr 28.
- Reddy VY, Neuzil P, Koruth JS, Petru J, Funosako M, Cochet H, Sediva L, Chovanec M, Dukkipati SR, Jais P. Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation. J Am Coll Cardiol. 2019 Jul 23;74(3):315-326. doi: 10.1016/j.jacc.2019.04.021. Epub 2019 May 11.
- Lakkireddy D, Thaler D, Ellis CR, Swarup V, Sondergaard L, Carroll J, Gold MR, Hermiller J, Diener HC, Schmidt B, MacDonald L, Mansour M, Maini B, O'Brien L, Windecker S. Amplatzer Amulet Left Atrial Appendage Occluder Versus Watchman Device for Stroke Prophylaxis (Amulet IDE): A Randomized, Controlled Trial. Circulation. 2021 Nov 9;144(19):1543-1552. doi: 10.1161/CIRCULATIONAHA.121.057063. Epub 2021 Aug 30.
- Tzikas A, Holmes DR Jr, Gafoor S, Ruiz CE, Blomstrom-Lundqvist C, Diener HC, Cappato R, Kar S, Lee RJ, Byrne RA, Ibrahim R, Lakkireddy D, Soliman OI, Nabauer M, Schneider S, Brachmann J, Saver JL, Tiemann K, Sievert H, Camm AJ, Lewalter T. Percutaneous left atrial appendage occlusion: the Munich consensus document on definitions, endpoints, and data collection requirements for clinical studies. Europace. 2017 Jan;19(1):4-15. doi: 10.1093/europace/euw141. Epub 2016 Aug 18.
- Hindricks G, Potpara T, Dagres N, Arbelo E, Bax JJ, Blomstrom-Lundqvist C, Boriani G, Castella M, Dan GA, Dilaveris PE, Fauchier L, Filippatos G, Kalman JM, La Meir M, Lane DA, Lebeau JP, Lettino M, Lip GYH, Pinto FJ, Thomas GN, Valgimigli M, Van Gelder IC, Van Putte BP, Watkins CL; ESC Scientific Document Group. 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): The Task Force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology (ESC) Developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC. Eur Heart J. 2021 Feb 1;42(5):373-498. doi: 10.1093/eurheartj/ehaa612. No abstract available.
- January CT, Wann LS, Calkins H, Chen LY, Cigarroa JE, Cleveland JC Jr, Ellinor PT, Ezekowitz MD, Field ME, Furie KL, Heidenreich PA, Murray KT, Shea JB, Tracy CM, Yancy CW. 2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2019 Jul 9;74(1):104-132. doi: 10.1016/j.jacc.2019.01.011. Epub 2019 Jan 28. No abstract available.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 2022.494
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .