- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07219290
- Juicio original
Función pulmonar según la posición de la camada
A litter is often needed to extract a person from an austere environment like the wilderness or from confined, urban spaces. A horizontal litter is generally assumed to be better for patient care, but often makes for a more difficult, if not impossible, evacuation from some settings such as confined space rescue, cave rescue, or wilderness rescue when the litter must be moved up or down a cliff with an undercut edge. A litter in a vertical orientation is easier to move in these situations, which may expedite movement towards definitive care. In some wilderness rescue circles, the mantra is that movement IS definitive care. It is already known that lying flat on the ground negatively affects pulmonary function compared to a sitting baseline.1 It is possible that a vertically oriented litter is better for a subset of patients with respiratory issues than a horizontal litter. The investigators hypothesize that pulmonary function measured by FEV1, FVC, and FEV1/FVC, is better in simulated patients in a vertically oriented litter compared to a horizontally oriented one.
Descripción general del estudio
Estado
Intervención / Tratamiento
Descripción detallada
Objective To quantify changes in pulmonary function tests (PFTs) based on litter position.
Hypotheses:
- Compared to sitting baseline, all PFTs in the litter will have decreased forced vital capacity (FVC) and 1 second forced expiratory volume (FEV1).
- Compared to lying down, persons straight upright and pitched forward will have better forced vital capacity (FVC) and 1 second forced expiratory volume (FEV1).
- We do not hypothesize any changes in FEV1/FVC.
Study Design This randomized crossover study will use twelve healthy volunteers. All subjects will do baseline sitting pulmonary testing. Experimental order is balanced to avoid any training effects. Choice of sequence will be by random selection of envelope.
Methods Once consented, included subjects will do baseline sitting measurement of FEV1 and FVC which will give FEV1/FVC. Each subject will then be secured in a Ferno-Washington Model 71 litter wearing their own type 2 or 3 harness, or in a UL tested CMC ATOM Global Harness (California Mountain Corporation, Santa Barbara, CA) meeting ANSI Z359.11-2014 and NFPA 1983-2017 standards, if they don't have their own. The person will be secured with double Vs from the litter sides to the harness and footloops supporting them so their weight is on their feet and only minimally on the harness (if vertical). This process is consistent with industry standards for securing a patient in the litter and follows the specific model of the National Cave Rescue Commission.3 See figure 1 Prior to being secured in the litter the patient will do sitting baseline FEV1 and FVC with an NDDD spirograph. Once there is baseline data the subject will be secured in the litter. The investigators will then repeat spirometry, pulse, and blood pressure in a horizontal position (see figure 2), in a vertical position (see figure 3), and pitched slightly forward in a position that results from a Pike and Pivot rigging for raising up past a difficult cliff edge (see figure 4). The subject will get a rest period in their preferred position until pulse returns to within 5 beats of baseline.
Litter suspension will be with a four-legged litter spider when horizontal, with a high bridle tied directly to the litter head for the full vertical position, and from a low bridle in Pike-and-Pivot formation when pitched forward. The litter will be lifted into position with a 3:1 mechanical advantage system tied to an anchor. No matter the position, the lowest point of the litter will be no more than 6 inches off of the ground. The system will be configured for immediate lower for any expressed concern. The PI (RM) is a technical rescue instructor for the National Cave Rescue Commission and Assistant Training Officer-Technical Rescue for Fresno County search and rescue. The Co-PIs (SS and SD) are on the rope team of Fresno County search and rescue. Each is well versed in rope systems, anchor selection, and patient packaging.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
California
-
Fresno, California, Estados Unidos, 93701
- UCSF Fresno
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- 130-310 pounds
Exclusion Criteria:
- Significant cardiac or pulmonary diseae
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Cuidados de apoyo
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación Secuencial
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Comparador activo: Flat
Secured in a flat litter |
Testing basic pulmonary function in three positions in a rescue litter, compared to sitting baseline |
|
Comparador activo: Vertical
Secured in a vertical litter |
Testing basic pulmonary function in three positions in a rescue litter, compared to sitting baseline |
|
Comparador activo: Pitched forward
Secured in a litter leaning forward |
Testing basic pulmonary function in three positions in a rescue litter, compared to sitting baseline |
|
Comparador de placebos: Baseline
Sitting baseline pulmonary function |
Testing basic pulmonary function in three positions in a rescue litter, compared to sitting baseline |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Forced Vital Capacity
Periodo de tiempo: Immediately
|
Measurable lung volume on expiration |
Immediately
|
Otras medidas de resultado
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
FEV1
Periodo de tiempo: Immediately
|
Air volume exhaled in 1 second |
Immediately
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Roger B Mortimer, MD, UCSF - Fresno
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- 25-45106
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Descripción del plan IPD
Deidentified data will be submitted to a statistician
Marco de tiempo para compartir IPD
1/1/26 to 6/1/26
Criterios de acceso compartido de IPD
Roger Mortimer, MD Sarah Davis, DO Sue Spano, MD Amanda Mortimer, PhD
Tipo de información de apoyo para compartir IPD
- PROTOCOLO DE ESTUDIO
- SAVIA
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .