Kortikaalisen luukudoksen ominaisuuksien käyttö murtumariskin arvioinnissa
The objective of this study is to determine whether a new minimally invasive method for in vivo measurement of cortical bone tissue properties can identify those who are at risk for fragility fractures of the hip and radius. The investigators hypothesis is that women with fragility fractures of the hip and radius have altered cortical bone tissue properties compared to non-fracture controls independent of standard clinical tests, such as bone mineral density (BMD) by dual-energy x-ray absorptiometry (DXA).
Tutkimuksen yleiskatsaus
Tila
Interventio / Hoito
Yksityiskohtainen kuvaus
The objective of this study is to determine whether a new minimally invasive method for in vivo measurement of cortical bone tissue properties can identify those who are at risk for fragility fractures of the hip and radius. The investigators hypothesis is that women with fragility fractures of the hip and radius have altered cortical bone tissue properties compared to non-fracture controls independent of standard clinical tests, such as BMD. To test these hypotheses, The investigators propose two aims:
Aim 1: Compare cortical bone tissue properties as assessed in vivo by reference point indentation in women with hip fractures and non-fracture controls.
The investigators will compare cortical bone tissue material properties, as assessed by novel in vivo indentation at the mid-tibia in postmenopausal women with recent hip fractures (n) and age-similar controls without fractures (n=). In addition to in vivo indentation measurements, The investigators will assess hip and spine BMD by DXA; as well as other factors that may influence risk of fractures (e.g, vit D status, medication use and physical activity). Hypotheses: Postmenopausal women with hip fractures will have worse bone tissue material properties compared to non-fracture controls even after adjustment for BMD and other potential confounders.
Aim 2: Compare cortical bone tissue properties as assessed in vivo by reference point indentation in women with distal radius fractures to non-fracture controls.
The investigators will compare cortical bone tissue material properties, as assessed by novel in vivo indentation at the mid-tibia in postmenopausal women with recent distal radius fractures (n) and age-similar controls without fractures (n=). In addition to in vivo indentation measurements, The investigators will assess hip and spine BMD by DXA; as well as other factors that may influence risk of fractures (e.g, vit D status, medication use and physical activity). Hypotheses: Postmenopausal women with distal radius fractures will have worse bone tissue material properties compared to non-fracture controls even after adjustment for BMD and other potential confounders.
Successful completion of this project will address the need to better assess bone mechanical properties at the tissue level in order to accurately predict fracture risk. The study will provide novel information about possible clinical utility of minimally invasive, in vivo bone indentation measurements to measure bone strength and its relationship to fracture risk.
Aim 3: An amendment to the protocol expanded the study population to now include males >50 years who present with distal radius fractures and those who present for a reason other than fracture (non-fracture controls). Hypotheses: Men >50 years with distal radius fractures will have worse bone tissue material properties compared to non-fracture controls even after adjustment for BMD and other potential confounders.
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Massachusetts
-
Boston, Massachusetts, Yhdysvallat, 02215
- Beth Israel Deaconess Medical Center
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Women with hip and wrist fractures within 2 weeks of presentation
- Non-fracture controls
Exclusion Criteria:
- Unable to undergo BMD by DXA or high-resolution peripheral quantitative computed tomography (HR-pQCT)
- History of skeletal metastasis, primary hyperparathyroidism, Paget's disease, multiple myeloma
- Treatment with bisphosphonate, estrogen (within previous 3 years), teriparatide therapy, calcitonin, selective estrogen receptor modulator (SERMs,within previous 3 years)
- Use of glucocorticoids continuously for more than 3 months, use of anticonvulsants
- Prior fracture in adulthood (>age 18) for healthy controls
Amendment to protocol added Arm 2, to include males >50 years with otherwise similar eligibility criteria.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Ennaltaehkäisy
- Jako: Ei satunnaistettu
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: Post-menopausal women
We will use the handheld Osteoprobe device to measure cortical bone reference point indentation properties. |
The "Osteoprobe": Since these first reports of indentation measurements in humans in vivo, a more 'user-friendly' device, the Osteoprobe® has been developed by Active Life Scientific (Santa Barbara, CA) (10). The Osteoprobe®, which we will use in the current study, is smaller than the previous reference point indentation (RPI) instrument and is designed to be used in a hand-held fashion to allow for rapid measurements. The new instrument does not require a reference probe, because the inertia of the instrument keeps it adequately fixed in space during the short time of the indentation impact (~0.25 milliseconds). The main parameter measured is the distance that the probe further indents into the bone from the reference point. Key components of the Osteoprobe® include an impact generation mechanism, a displacement transducer, and a probe made of hardened stainless steel with a 90 degree conical tip, with a tip diameter of ~375 µm.
Muut nimet:
|
|
Kokeellinen: Males over 50 years
We will recruit males to this second study arm, to use the handheld Osteoprobe device to measure cortical bone reference point indentation properties. |
The "Osteoprobe": Since these first reports of indentation measurements in humans in vivo, a more 'user-friendly' device, the Osteoprobe® has been developed by Active Life Scientific (Santa Barbara, CA) (10). The Osteoprobe®, which we will use in the current study, is smaller than the previous reference point indentation (RPI) instrument and is designed to be used in a hand-held fashion to allow for rapid measurements. The new instrument does not require a reference probe, because the inertia of the instrument keeps it adequately fixed in space during the short time of the indentation impact (~0.25 milliseconds). The main parameter measured is the distance that the probe further indents into the bone from the reference point. Key components of the Osteoprobe® include an impact generation mechanism, a displacement transducer, and a probe made of hardened stainless steel with a 90 degree conical tip, with a tip diameter of ~375 µm.
Muut nimet:
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Cortical bone tissue properties by reference point indentation
Aikaikkuna: Day 1
|
Osteoprobe measurement |
Day 1
|
|
Bone mineral density (BMD) by dual-energy x-ray absorptiometry (DXA)
Aikaikkuna: Day 1
|
DXA at the hip and spine |
Day 1
|
Yhteistyökumppanit ja tutkijat
Sponsori
Yhteistyökumppanit
Tutkijat
- Päätutkija: Tamara Rozental, M.D., Beth Israel Deaconess Medical Center
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Arvioitu)
Opintojen valmistuminen (Arvioitu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- 2014P000226
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Yhdysvalloissa valmistettu ja sieltä viety tuote
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .