- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT03372278
PMCF-tutkimus Zimmer® Maxera™ Acetabular -järjestelmän turvallisuudesta ja suorituskyvystä lonkan kokonaisartroplastiassa
Zimmer® Maxera™ Acetabular System lonkkanivelleikkauksessa. Monikeskus, potentiaalinen, kontrolloimaton markkinoille saattamisen jälkeinen kliininen seurantatutkimus
This study is a multicenter, prospective, non-controlled post market clinical follow-up study. The objectives of this study are to confirm the safety and performance of the commercially available Zimmer® Maxera™ Acetabular System in Total Hip Arthroplasty.
Tutkimuksen yleiskatsaus
Tila
Yksityiskohtainen kuvaus
The objectives of this study are to confirm the safety and performance of the Zimmer Maxera Cup mated with either a BIOLOX® delta or BIOLOX® OPTION femoral head when used in primary total hip arthroplasty.
In total 250 patients will be enrolled into the study at up to 10 sites.All potential study subjects will be required to participate in the Informed Consent Process.
Opintotyyppi
Ilmoittautuminen (Todellinen)
Yhteystiedot ja paikat
Opiskelupaikat
-
-
-
Delft, Alankomaat
- Reinier de Graaf Groep
-
-
-
-
-
Sydney, Australia
- The Mater Hospital, Concord Hospital
-
-
-
-
-
Pellenberg, Belgia
- UZ Leuven
-
-
-
-
-
Palma de Mallorca, Espanja
- Hospital Son Llatzer
-
-
-
-
-
Montreal, Kanada
- Center Maisonneuve-Rosemont Hospital
-
-
-
-
-
Perpignan, Ranska
- Centre Hospitalier de Perpignan
-
-
-
-
-
Jämsä, Suomi
- Jokilaakson terveys oy
-
-
-
-
-
Liverpool, Yhdistynyt kuningaskunta
- Royal Liverpool and Broadgreen University Teaching Hospitals
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Näytteenottomenetelmä
Tutkimusväestö
Patients suffering from severe hip pain and disability requiring total hip arthroplasty and who meet the inclusion/exclusion criteria
Kuvaus
Inclusion Criteria:
-
Patient is 18 to 75 years of age, inclusive.
-
Patient is skeletally mature.
-
Patient qualifies for primary unilateral or simultaneous bilateral total hip arthroplasty (THA) based on physical exam and medical history including at least one of the following:
- Osteoarthritis
- Avascular necrosis (AVN)
- Inflammatory arthritis
- Rheumatoid arthritis with adequate bone quality
- Post-traumatic arthritis
- Congenital hip dysplasia.
-
Patient has no history of previous total hip replacement or arthrodesis of the affected hip joint(s). Patient has a Harris Hip Score <70 in the affected hip and a Harris Hip pain rating of moderate, marked, or disabled.
-
Patient is willing and able to provide written informed consent.
-
Patient is willing and able to cooperate in the required post-operative therapy.
-
Patient is willing and able to complete scheduled follow-up evaluations as described in the Informed Consent.
-
Patient has participated in the Informed Consent process and has signed the Ethics Committee approved informed consent.
Exclusion Criteria:
-
The patient is:
- A prisoner
- Mentally incompetent or unable to understand what participation in the study entails.
- A known alcohol or drug abuser
- Anticipated to be non-compliant
-
The patient has a neuromuscular disorder, vascular disorder or other condition that could contribute to prosthesis instability, prosthesis fixation failure, or complications in postoperative care.
-
The patient has local bone tumors and/or cysts in the portion of bone to be retained in the operative hip that could inhibit implant fixation.
-
The patient has insufficient bone stock or poor bone quality to fix the component. Insufficient bone stock exists in the presence of metabolic bone disease (i.e. osteoporosis), cancer, and radiation. Note: Dual Energy X-ray Absorptiometry (DEXA) may be required to assess the presence of adequate bone stock.
-
The patient has rapid disease progression as obvious by joint destruction or bone absorption seen on x-ray.
-
The patient has osteoradionecrosis in the affected hip.
-
The patient has a neuromuscular condition in the ipsilateral or contralateral limb which affects lower limb function.
-
The patient has loss of abductor musculature in the affected hip.
-
The patient has a vascular (large and small vessel disease) insufficiency.
-
The patient has had previous prosthetic hip replacement device (any type, including surface replacement arthroplasty, endoprosthesis, etc.) in the joint to be operated.
-
The patient has had previous girdlestone procedure (resection arthroplasty) or surgical fusion of the hip to be operated.
-
The patient has an acute femoral neck fracture in the operative hip.
-
The patient has had a procedure on the operative hip in the last 6 months (i.e. arthroscopy, ORIF femoral neck fracture, etc).
-
The patient has undergone a total hip replacement, endoprosthesis, or surface arthroplasty of the contralateral (opposite side) hip within the past 6 months regardless of whether the previous hip was enrolled in this clinical study.
-
The patient has a moderate to severe limb length discrepancy greater than 3.2 cm.
-
The patient has an active, old or remote infection in or about the affected hip joint or an infection distant from the hip joint that may spread to the hip hematogenously.
-
The patient has poor skin coverage around the affected hip joint.
-
The patient has a diagnosed systemic disease that could affect his/her safety or the study outcome.
-
The patient is currently receiving, or within the past three months, has received any drug known to potentially interfere with bone/soft tissue healing (e.g. long-term chronic systemic steroid or inhaler steroid therapy).
-
The patient has received an investigational drug or device within the previous 6 months.
-
The patient is known to be pregnant.
-
The patient is unwilling or unable to give informed consent, or to comply with the followup program.
-
The patient is known to have a highly communicable disease that may limit follow-up.
-
The patient has a known sensitivity or allergic reaction to one or more of the implanted materials which include metal and ceramic.
-
The patient is Grade III obese with a Body Mass Index (BMI) > 35.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Havaintomallit: COHORT
- Aikanäkymät: PROSPECTIVE
Kohortit ja interventiot
Ryhmä/Kohortti |
|---|
|
Patients who received the Maxera Cup
Subjects in need of a total hip arthroplasty, who met the inclusion/exclusion criteria and who received the Maxera Cup. |
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Aikaikkuna |
|---|---|
|
Implantin eloonjääminen perustuu laitteen poistoon tai aiottuun poistoon ja määritetty Kaplan-Meier-menetelmällä
Aikaikkuna: 10 vuotta leikkauksen jälkeen
|
10 vuotta leikkauksen jälkeen
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Aikaikkuna |
|---|---|
|
Mahdollisiin komplikaatioihin perustuva turvallisuus, mukaan lukien sijoitukset ja korjaukset/poistot
Aikaikkuna: 10 vuotta leikkauksen jälkeen
|
10 vuotta leikkauksen jälkeen
|
|
Röntgenkuvat, jotka on arvioitu radiolucensioiden, osteolyysin, hypertrofian, vajoamisen, heterotooppisen luutumisen jne.
Aikaikkuna: 10 vuotta leikkauksen jälkeen
|
10 vuotta leikkauksen jälkeen
|
|
Kipu ja toimintakyky perustuu Harris Hip Score
Aikaikkuna: 10 vuotta leikkauksen jälkeen
|
10 vuotta leikkauksen jälkeen
|
|
Kipu ja toimintakyky perustuu UCLA Score
Aikaikkuna: 10 vuotta leikkauksen jälkeen
|
10 vuotta leikkauksen jälkeen
|
|
Koehenkilön elämänlaatu määräytyy EQ-5D (EuroQoI) -pistemäärän perusteella
Aikaikkuna: 10 vuotta leikkauksen jälkeen
|
10 vuotta leikkauksen jälkeen
|
Yhteistyökumppanit ja tutkijat
Sponsori
Tutkijat
- Opintojohtaja: Hassan Achakri, Zimmer Biomet
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Arvioitu)
Opintojen valmistuminen (Arvioitu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
- Luun sairaudet
- Tuki- ja liikuntaelinten sairaudet
- Patologiset prosessit
- Nivelsairaudet
- Reumaattiset sairaudet
- Nekroosi
- Tuki- ja liikuntaelimistön poikkeavuudet
- Synnynnäiset poikkeavuudet
- Synnynnäiset, perinnölliset ja vastasyntyneiden sairaudet ja poikkeavuudet
- Patologiset tilat, merkit ja oireet
- Lonkan kehitysdysplasia
- Niveltulehdus
- Nivelrikko
- Nivelrikko, lonkka
- Lonkan dislokaatio, synnynnäinen
- Osteonekroosi
Muut tutkimustunnusnumerot
- CIE2011-01H
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Yhdysvalloissa valmistettu ja sieltä viety tuote
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .