Registre prospectif brésilien du stent à élution médicamenteuse Inspiron EVO dans les lésions coronaires complexes (PCI EVOlution)
Registre prospectif national du stent à élution de médicament Inspiron EVO dans les lésions coronariennes complexes
The objective is to evaluate the efficacy and safety of the Inspiron™ EVO drug-eluting stent in complex coronary lesions in a real-world population. Patients with symptomatic ischemic heart disease due to lesions in native coronary arteries and restenotic lesions will be treated with the Inspiron™ EVO drug-eluting stent.
Aperçu de l'étude
Statut
Statut
Les conditions
Les conditions
Intervention / Traitement
Intervention / Traitement
Description détaillée
Post-marketing, observational, prospective, multi-center, non-randomized, single-arm registry that will include all patients who receive the Inspiron™ EVO stent at participating sites and meet the eligibility criteria.
Up to 2,000 patients are expected to be enrolled across 12 research sites in Brazil. Participants' demographic, procedural, and follow-up data will be collected for up to 12 months in this study.
Type d'étude
Type d'étude
Inscription (Estimé)
Inscription
Contacts et emplacements
Coordonnées de l'étude
Coordonnées de l'étude
- Nom: Marco Aurélio A Costa, MD, PhD
- Numéro de téléphone: +1 216 903-9327
- E-mail: marco.costa@scitechmed.com
Sauvegarde des contacts de l'étude
- Nom: Ana Paula B Pellaquim, MSc.
- Numéro de téléphone: +55 62 9471-4439
- E-mail: aalmeida@scitechmed.com
Lieux d'étude
-
-
Rio Grande do Sul
-
Porto Alegre, Rio Grande do Sul, Brésil, 90610000
- Recrutement
- Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
-
Contact:
- Paulo Ricardo A Caramori, MD
- Numéro de téléphone: +55 51 99982 0766
- E-mail: caramori@cardiarte.com.br
-
Contact:
- Rosa Homem
- Numéro de téléphone: +55 51 99679 8040
- E-mail: cer.pesquisaclinica@gmail.com
-
-
Critères de participation
Critère d'éligibilité
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
Patients with symptomatic ischemic heart disease due to lesions in native coronary arteries and restenotic lesions treated with the Inspiron™ EVO Drug-Eluting Stent.
La description
Inclusion Criteria:
- Individuals aged 18 years or older presenting with complex coronary lesions requiring percutaneous coronary intervention (PCI).
- Individuals who provide consent and are willing to comply with the follow-up protocol.
- Individuals who received treatment with the Inspiron™ EVO Stent.
- Individuals with lesions ≥ 30 mm in length (Subprotocol 1).
- Individuals with significantly calcified coronary lesions (moderate to severe according to the ACC/AHA classification B1, B2, or C), with or without indication for lesion preparation techniques (Subprotocol 2).
- Individuals with multivessel coronary artery disease (≥2 affected coronary vessels, with at least one vessel of small diameter ≤2.5 mm) (Subprotocol 3).
- Individuals included in Subprotocol 1, 2, or 3. The evaluated segment must be accessible to the IVUS (Intravascular Ultrasound) catheter (Subprotocol 4).
Exclusion Criteria:
- Lesions in saphenous vein grafts or internal mammary grafts.
- Contraindication to the use of a drug-eluting stent.
- Individuals who were treated during the index procedure with any stent other than the Inspiron™ EVO Stent.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: COHORT
- Perspectives temporelles: PROSPECTIVE
Nombre de groupes / cohortes
Cohortes et interventions
Groupe / CohorteGroupe / Cohorte |
Intervention / TraitementIntervention / Traitement |
|---|---|
|
Experimental: Percutaneous coronary intervention (PCI)
Patients with symptomatic ischemic heart disease due to lesions in the native coronary artery and restenotic lesions treated with the Inspiron™ EVO drug-eluting stent. |
Percutaneous coronary intervention (PCI) using the Inspiron EVO Drug-Eluting Stent, which has a reduced crimped profile, providing greater safety and facilitating lesion crossing. In addition, the design is optimized to provide increased radial strength. |
Que mesure l'étude ?
Principaux critères de jugement
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Device success
Délai: Initial procedure
|
Device success (at the lesion level) is defined as the successful delivery, balloon expansion, and implantation of the first device at the target lesion (with multiple attempts using the same device permitted), successful withdrawal of the delivery system, and achievement of a final in-stent residual stenosis of <20% |
Initial procedure
|
|
Acute Clinical Success of Percutaneous Coronary Intervention (PCI)
Délai: Up to 24 hours
|
Defined as the absence of major adverse in-hospital cardiac events (death, myocardial infarction, or repeat coronary revascularization of the target lesion). |
Up to 24 hours
|
|
MACE (Major Adverse Cardiac Events) rate
Délai: 12 months
|
Defined as the combination of cardiac death, myocardial infarction (MI), or revascularization of the target lesion (TLR). |
12 months
|
Mesures de résultats secondaires
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Target Lesion Revascularization (TLR) rate
Délai: 12 months
|
TLR is defined as any percutaneous reintervention of the target lesion, including the 5 mm proximal and 5 mm distal segments of the stent, or revascularization of the target vessel, performed for clinical reasons due to restenosis or occlusion of the target lesion. |
12 months
|
|
Target vessel revascularization rate (TVR)
Délai: 12 months
|
TVR is defined as revascularization of any segment of the target coronary artery. |
12 months
|
|
Target Vessel Failure Rate (TVF)
Délai: 12 months
|
Defined as a combination of MI, TLR, or cardiovascular death related to the target vessel. If it is not possible to determine with certainty whether the MI or death was related to the target vessel, the case is considered a TVF. |
12 months
|
|
Rate of definite, probable, and possible stent thrombosis (ST)
Délai: 12 months
|
Stent thrombosis is classified as definite, probable, or possible: definite requires angiographic or pathological confirmation; probable includes unexplained death within 30 days or myocardial infarction related to the stented territory without angiographic confirmation; and possible refers to any unexplained death occurring from 30 days after implantation until the end of follow-up. |
12 months
|
|
Cardiovascular mortality
Délai: 12 months
|
Any death due to an immediate cardiac cause (e.g., myocardial infarction, low-output heart failure, fatal arrhythmia), unwitnessed death, death of unknown cause, and all procedure-related deaths, including those related to concomitant treatment, will be classified as cardiac death. |
12 months
|
|
Late in-segment luminal loss (including the in-stent portion and the 5-mm proximal and distal edges)
Délai: 6 months
|
Defined as the difference between the in-segment minimum luminal diameter (MLD) (including the in-stent portion and the 5-mm proximal and distal edges) after the procedure and the MLD at the 6-month follow-up, as determined by quantitative angiography. |
6 months
|
|
Percent Area Stenosis (%AS)
Délai: 6 months
|
Defined as the ratio between the neointimal hyperplasia area and the stent area multiplied by 100 at the 6-month follow-up. |
6 months
|
Collaborateurs et enquêteurs
Parrainer
Parrainer
Les enquêteurs
Les enquêteurs
- Chercheur principal: Paulo Ricardo A Caramori, MD, Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Début de l'étude
Achèvement primaire (Estimé)
Achèvement primaire
Achèvement de l'étude (Estimé)
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Première publication
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour publiée
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
Autres numéros d'identification d'étude
- SCI-EV-001
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .