Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Registo Prospectivo Brasileiro do Stent Farmacológico Inspiron EVO em Lesões Coronárias Complexas (PCI EVOlution)

1 de outubro de 2026 atualizado por: Scitech Produtos Medicos SA

Registo Prospectivo Nacional do Stent Farmacológico Inspiron EVO em Lesões Coronárias Complexas

The objective is to evaluate the efficacy and safety of the Inspiron™ EVO drug-eluting stent in complex coronary lesions in a real-world population. Patients with symptomatic ischemic heart disease due to lesions in native coronary arteries and restenotic lesions will be treated with the Inspiron™ EVO drug-eluting stent.

Visão geral do estudo

Status

Recrutamento

Condições

Intervenção / Tratamento

Descrição detalhada

Post-marketing, observational, prospective, multi-center, non-randomized, single-arm registry that will include all patients who receive the Inspiron™ EVO stent at participating sites and meet the eligibility criteria.

Up to 2,000 patients are expected to be enrolled across 12 research sites in Brazil. Participants' demographic, procedural, and follow-up data will be collected for up to 12 months in this study.

Tipo de estudo

Observacional

Inscrição (Estimado)

2000

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Estude backup de contato

Locais de estudo

    • Rio Grande do Sul
      • Porto Alegre, Rio Grande do Sul, Brasil, 90610000
        • Recrutamento
        • Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
        • Contato:
        • Contato:

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Método de amostragem

Amostra Não Probabilística

População do estudo

Patients with symptomatic ischemic heart disease due to lesions in native coronary arteries and restenotic lesions treated with the Inspiron™ EVO Drug-Eluting Stent.

Descrição

Inclusion Criteria:

  • Individuals aged 18 years or older presenting with complex coronary lesions requiring percutaneous coronary intervention (PCI).
  • Individuals who provide consent and are willing to comply with the follow-up protocol.
  • Individuals who received treatment with the Inspiron™ EVO Stent.
  • Individuals with lesions ≥ 30 mm in length (Subprotocol 1).
  • Individuals with significantly calcified coronary lesions (moderate to severe according to the ACC/AHA classification B1, B2, or C), with or without indication for lesion preparation techniques (Subprotocol 2).
  • Individuals with multivessel coronary artery disease (≥2 affected coronary vessels, with at least one vessel of small diameter ≤2.5 mm) (Subprotocol 3).
  • Individuals included in Subprotocol 1, 2, or 3. The evaluated segment must be accessible to the IVUS (Intravascular Ultrasound) catheter (Subprotocol 4).

Exclusion Criteria:

  • Lesions in saphenous vein grafts or internal mammary grafts.
  • Contraindication to the use of a drug-eluting stent.
  • Individuals who were treated during the index procedure with any stent other than the Inspiron™ EVO Stent.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Modelos de observação: COHORT
  • Perspectivas de Tempo: PROSPECTIVE

Coortes e Intervenções

Grupo / Coorte
Intervenção / Tratamento
Experimental: Percutaneous coronary intervention (PCI)

Patients with symptomatic ischemic heart disease due to lesions in the native coronary artery and restenotic lesions treated with the Inspiron™ EVO drug-eluting stent.

Percutaneous coronary intervention (PCI) using the Inspiron EVO Drug-Eluting Stent, which has a reduced crimped profile, providing greater safety and facilitating lesion crossing. In addition, the design is optimized to provide increased radial strength.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Device success
Prazo: Initial procedure

Device success (at the lesion level) is defined as the successful delivery, balloon expansion, and implantation of the first device at the target lesion (with multiple attempts using the same device permitted), successful withdrawal of the delivery system, and achievement of a final in-stent residual stenosis of <20%

Initial procedure
Acute Clinical Success of Percutaneous Coronary Intervention (PCI)
Prazo: Up to 24 hours

Defined as the absence of major adverse in-hospital cardiac events (death, myocardial infarction, or repeat coronary revascularization of the target lesion).

Up to 24 hours
MACE (Major Adverse Cardiac Events) rate
Prazo: 12 months

Defined as the combination of cardiac death, myocardial infarction (MI), or revascularization of the target lesion (TLR).

12 months

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Target Lesion Revascularization (TLR) rate
Prazo: 12 months

TLR is defined as any percutaneous reintervention of the target lesion, including the 5 mm proximal and 5 mm distal segments of the stent, or revascularization of the target vessel, performed for clinical reasons due to restenosis or occlusion of the target lesion.

12 months
Target vessel revascularization rate (TVR)
Prazo: 12 months

TVR is defined as revascularization of any segment of the target coronary artery.

12 months
Target Vessel Failure Rate (TVF)
Prazo: 12 months

Defined as a combination of MI, TLR, or cardiovascular death related to the target vessel. If it is not possible to determine with certainty whether the MI or death was related to the target vessel, the case is considered a TVF.

12 months
Rate of definite, probable, and possible stent thrombosis (ST)
Prazo: 12 months

Stent thrombosis is classified as definite, probable, or possible: definite requires angiographic or pathological confirmation; probable includes unexplained death within 30 days or myocardial infarction related to the stented territory without angiographic confirmation; and possible refers to any unexplained death occurring from 30 days after implantation until the end of follow-up.

12 months
Cardiovascular mortality
Prazo: 12 months

Any death due to an immediate cardiac cause (e.g., myocardial infarction, low-output heart failure, fatal arrhythmia), unwitnessed death, death of unknown cause, and all procedure-related deaths, including those related to concomitant treatment, will be classified as cardiac death.

12 months
Late in-segment luminal loss (including the in-stent portion and the 5-mm proximal and distal edges)
Prazo: 6 months

Defined as the difference between the in-segment minimum luminal diameter (MLD) (including the in-stent portion and the 5-mm proximal and distal edges) after the procedure and the MLD at the 6-month follow-up, as determined by quantitative angiography.

6 months
Percent Area Stenosis (%AS)
Prazo: 6 months

Defined as the ratio between the neointimal hyperplasia area and the stent area multiplied by 100 at the 6-month follow-up.

6 months

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Investigador principal: Paulo Ricardo A Caramori, MD, Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

30 de outubro de 2026

Conclusão Primária (Estimado)

30 de outubro de 2030

Conclusão do estudo (Estimado)

30 de outubro de 2030

Datas de inscrição no estudo

Enviado pela primeira vez

16 de março de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

19 de março de 2026

Primeira postagem (Real)

24 de março de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

2 de outubro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

1 de outubro de 2026

Última verificação

1 de outubro de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • SCI-EV-001

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .