Registro Prospettico Brasiliano dello Stent Coronarico a Rilascio di Farmaco Inspiron EVO nelle Lesioni Coronariche Complesse (PCI EVOlution)
Registro Nazionale Prospettico dello Stent Coronarico a Rilascio Farmacologico Inspiron EVO nelle Lesioni Coronariche Complesse
The objective is to evaluate the efficacy and safety of the Inspiron™ EVO drug-eluting stent in complex coronary lesions in a real-world population. Patients with symptomatic ischemic heart disease due to lesions in native coronary arteries and restenotic lesions will be treated with the Inspiron™ EVO drug-eluting stent.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Post-marketing, observational, prospective, multi-center, non-randomized, single-arm registry that will include all patients who receive the Inspiron™ EVO stent at participating sites and meet the eligibility criteria.
Up to 2,000 patients are expected to be enrolled across 12 research sites in Brazil. Participants' demographic, procedural, and follow-up data will be collected for up to 12 months in this study.
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Marco Aurélio A Costa, MD, PhD
- Numero di telefono: +1 216 903-9327
- Email: marco.costa@scitechmed.com
Backup dei contatti dello studio
- Nome: Ana Paula B Pellaquim, MSc.
- Numero di telefono: +55 62 9471-4439
- Email: aalmeida@scitechmed.com
Luoghi di studio
-
-
Rio Grande do Sul
-
Porto Alegre, Rio Grande do Sul, Brasile, 90610000
- Reclutamento
- Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
-
Contatto:
- Paulo Ricardo A Caramori, MD
- Numero di telefono: +55 51 99982 0766
- Email: caramori@cardiarte.com.br
-
Contatto:
- Rosa Homem
- Numero di telefono: +55 51 99679 8040
- Email: cer.pesquisaclinica@gmail.com
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Patients with symptomatic ischemic heart disease due to lesions in native coronary arteries and restenotic lesions treated with the Inspiron™ EVO Drug-Eluting Stent.
Descrizione
Inclusion Criteria:
- Individuals aged 18 years or older presenting with complex coronary lesions requiring percutaneous coronary intervention (PCI).
- Individuals who provide consent and are willing to comply with the follow-up protocol.
- Individuals who received treatment with the Inspiron™ EVO Stent.
- Individuals with lesions ≥ 30 mm in length (Subprotocol 1).
- Individuals with significantly calcified coronary lesions (moderate to severe according to the ACC/AHA classification B1, B2, or C), with or without indication for lesion preparation techniques (Subprotocol 2).
- Individuals with multivessel coronary artery disease (≥2 affected coronary vessels, with at least one vessel of small diameter ≤2.5 mm) (Subprotocol 3).
- Individuals included in Subprotocol 1, 2, or 3. The evaluated segment must be accessible to the IVUS (Intravascular Ultrasound) catheter (Subprotocol 4).
Exclusion Criteria:
- Lesions in saphenous vein grafts or internal mammary grafts.
- Contraindication to the use of a drug-eluting stent.
- Individuals who were treated during the index procedure with any stent other than the Inspiron™ EVO Stent.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Modelli osservazionali: COHORT
- Prospettive temporali: PROSPECTIVE
Numero di gruppi/coorti
Coorti e interventi
Gruppo / CoorteGruppo / Coorte |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Experimental: Percutaneous coronary intervention (PCI)
Patients with symptomatic ischemic heart disease due to lesions in the native coronary artery and restenotic lesions treated with the Inspiron™ EVO drug-eluting stent. |
Percutaneous coronary intervention (PCI) using the Inspiron EVO Drug-Eluting Stent, which has a reduced crimped profile, providing greater safety and facilitating lesion crossing. In addition, the design is optimized to provide increased radial strength. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Device success
Lasso di tempo: Initial procedure
|
Device success (at the lesion level) is defined as the successful delivery, balloon expansion, and implantation of the first device at the target lesion (with multiple attempts using the same device permitted), successful withdrawal of the delivery system, and achievement of a final in-stent residual stenosis of <20% |
Initial procedure
|
|
Acute Clinical Success of Percutaneous Coronary Intervention (PCI)
Lasso di tempo: Up to 24 hours
|
Defined as the absence of major adverse in-hospital cardiac events (death, myocardial infarction, or repeat coronary revascularization of the target lesion). |
Up to 24 hours
|
|
MACE (Major Adverse Cardiac Events) rate
Lasso di tempo: 12 months
|
Defined as the combination of cardiac death, myocardial infarction (MI), or revascularization of the target lesion (TLR). |
12 months
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Target Lesion Revascularization (TLR) rate
Lasso di tempo: 12 months
|
TLR is defined as any percutaneous reintervention of the target lesion, including the 5 mm proximal and 5 mm distal segments of the stent, or revascularization of the target vessel, performed for clinical reasons due to restenosis or occlusion of the target lesion. |
12 months
|
|
Target vessel revascularization rate (TVR)
Lasso di tempo: 12 months
|
TVR is defined as revascularization of any segment of the target coronary artery. |
12 months
|
|
Target Vessel Failure Rate (TVF)
Lasso di tempo: 12 months
|
Defined as a combination of MI, TLR, or cardiovascular death related to the target vessel. If it is not possible to determine with certainty whether the MI or death was related to the target vessel, the case is considered a TVF. |
12 months
|
|
Rate of definite, probable, and possible stent thrombosis (ST)
Lasso di tempo: 12 months
|
Stent thrombosis is classified as definite, probable, or possible: definite requires angiographic or pathological confirmation; probable includes unexplained death within 30 days or myocardial infarction related to the stented territory without angiographic confirmation; and possible refers to any unexplained death occurring from 30 days after implantation until the end of follow-up. |
12 months
|
|
Cardiovascular mortality
Lasso di tempo: 12 months
|
Any death due to an immediate cardiac cause (e.g., myocardial infarction, low-output heart failure, fatal arrhythmia), unwitnessed death, death of unknown cause, and all procedure-related deaths, including those related to concomitant treatment, will be classified as cardiac death. |
12 months
|
|
Late in-segment luminal loss (including the in-stent portion and the 5-mm proximal and distal edges)
Lasso di tempo: 6 months
|
Defined as the difference between the in-segment minimum luminal diameter (MLD) (including the in-stent portion and the 5-mm proximal and distal edges) after the procedure and the MLD at the 6-month follow-up, as determined by quantitative angiography. |
6 months
|
|
Percent Area Stenosis (%AS)
Lasso di tempo: 6 months
|
Defined as the ratio between the neointimal hyperplasia area and the stent area multiplied by 100 at the 6-month follow-up. |
6 months
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: Paulo Ricardo A Caramori, MD, Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- SCI-EV-001
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .