Système de remplacement de la hanche (HRS-P) dans l'arthroplastie totale primaire de la hanche ((HRS-P))
Une étude prospective multicentrique du système de remplacement de la hanche Hip Innovation Technology (HIT) dans l'arthroplastie totale primaire de la hanche
To evaluate effectiveness and safety of HHRS in subjects undergoing total hip arthroplasty (THA). Effectiveness will be evaluated using patient-reported, clinical, radiologic, and radiostereometric outcomes. Safety will be evaluated through the collection of device-related and unanticipated device-related adverse events.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
The HIT Hip Replacement System (HHRS) is a Metal-on-Polyethylene (MoP) conventional hip prosthesis. The HHRS consists of a femoral stem, an acetabular cup and a Cobalt Chromium Molybdenum (CoCrMo) ball that articulates within a polyethylene liner. The ball sits on the acetabular cup, and the polyethylene liner is attached to the femoral cup, which attaches to the femoral stem, instead of the acetabular cup. The acetabular component of the HHRS consists of a hemispherical acetabular shell with a clustered screw-hole design. The outside of the shells are coated with titanium plasma to facilitate bone in-growth and provide secure intermediate fixation with the prepared bone surface at the site of implantation. The acetabular cup has a 3-hole design that accommodates three titanium alloy bone screws. Inside the acetabular cup is a male taper for assembly with the acetabular ball. The femoral component consists of a femoral stem manufactured from titanium and a mating cobalt chrome femoral cup lined with a highly cross-linked ultra-high-molecular-weight polyethylene (UHMWPE). As with the acetabular cup, the femoral stem is porous coated using a plasma spray of pure titanium, which is intended to facilitate bone in-growth and provide secure intermediate fixation with the prepared bone surface at the site of implantation. The femoral stem incorporates a female taper for assembly with the male taper of the femoral cup.
The device has undergone extensive pre-clinical testing. There is no clinical experience with the HRS.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Linda Braddon, PhD
- Numéro de téléphone: 770-837-2681
- E-mail: LGB@SecureBME.com
Sauvegarde des contacts de l'étude
- Nom: Thomas Turgeon, MD
- Numéro de téléphone: 204-926-1218
- E-mail: tturgeon@cjrg.ca
Lieux d'étude
-
-
Manitoba
-
Winnipeg, Manitoba, Canada, R2K 2M9
- Recrutement
- Orthopaedic Innovation Centre
-
Contact:
- Thomas Turgeon, MD
- Numéro de téléphone: (204) 926-1218
- E-mail: tturgeon@cjrg.ca
-
Contact:
- Sarah Tran
- Numéro de téléphone: (204) 926-1231
- E-mail: stran@orthoinno.com
-
Chercheur principal:
- Thomas Turgeon, MD
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Patient has a non-inflammatory degenerative joint disease (NIDJD) or any of its composite diagnoses such as osteoarthritis, avascular necrosis, traumatic arthritis, slipped capital epiphysis, fracture of the pelvis, and diastrophic variant requiring unilateral primary total hip replacement.
- Age between 65 and 79 years (inclusive) at the time of enrollment.
- Patient is a suitable candidate for primary total hip replacement at the discretion of the Investigator.
- Pre-surgery (within 28 days before surgery) WOMAC Global Score of 40 or larger on a scale from 0 (best) to 96 (worst)
- Signed and dated informed consent document.
- Patient is willing and able to participate in required follow-up visits at the Investigational site and to complete study procedures and questionnaires.
Exclusion Criteria:
- Patient has had total hip replacement, hemi-arthroplasty, or fusion in either hip in the last 12 months;
- Patient has planned total hip arthroplasty on a contra-lateral joint in the next 12 months;
- Patient has a known allergy to any component of the study device;
- Patient has a history of active sepsis in the joint;
- Patient has an insufficient acetabular or femoral bone stock in which good anchorage of the implants are unlikely or impossible;
- Patient has total or partial absence of the muscular or ligamentous apparatus;
- Patient has known moderate to severe renal insufficiency;
- Patient has vascular insufficiency, muscular atrophy, or neuromuscular disease in either leg (based on the Investigator's discretion);
- Patient has a deformity of the affected limb or significant anatomic variance of the affected hip;
- Patient has an active malignancy or history of invasive malignancy within the last five years, with the exception of superficial basal cell carcinoma or squamous cell carcinoma of the skin that has been definitively treated. Patients with carcinoma in situ of the uterine cervix definitively treated more than 1 year prior to enrollment may enter the study;
- Patient has any condition which may, in the opinion of the Investigator, interfere with the total hip replacement survival or patient outcomes (e.g. Paget's disease, Charcot's disease);
- Patient has rheumatoid arthritis or other autoimmune condition that affect joints (e.g. Lupus Arthritis);
- Patient has any condition that would interfere with patient self-assessment or pain, the function or quality of life required for patient reported outcomes during the study (based on the Investigator's discretion);
- Body Mass Index (BMI) of 40 or more;
- Patient has an active infection (e.g. hepatitis, AIDS, ARC) - systemic or at the site of intended surgery;
- Patient is currently participating in any investigational study not related to this study's pre-operative or post-operative care;
- Patient has any other severe acute or chronic medical condition that may interfere with the interpretation of the study results, in the judgment of the Investigator, which would make the patient inappropriate for entry into this study;
- Patient has a history of metabolic bone disease (e.g. Paget's disease or osteomalacia);
- Patient is currently pregnant or is planning to become pregnant.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: HIT Hip Replacement System (HRS)
Single group assignment with historical controls. |
HIT Hip Replacement System |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Délai |
|---|---|
|
Changement du score des limitations fonctionnelles de l'échelle de Likert de Western Ontario et McMaster Universities Osteoarthritis Index (WOMAC) v3.0 entre le point de référence (préopératoire) et le suivi postopératoire de 730 jours.
Délai: entre préopératoire et 730 jours (24 mois)
|
entre préopératoire et 730 jours (24 mois)
|
|
Changement du score de la hanche de Harris entre le point de départ (préopératoire) et le point de suivi postopératoire de 730 jours.
Délai: entre préopératoire et 730 jours (24 mois)
|
entre préopératoire et 730 jours (24 mois)
|
Mesures de résultats secondaires
Mesure des résultats |
Délai |
|---|---|
|
Changement du score d'Oxford Hip entre 730 jours après l'opération et le départ (avant la chirurgie)
Délai: entre 730 jours postopératoires et la ligne de base (préopératoire)
|
entre 730 jours postopératoires et la ligne de base (préopératoire)
|
|
Modification du score de la composante physique (PCS) du formulaire court 36 v2 entre 730 jours après l'opération et la ligne de base (avant l'opération)
Délai: entre 730 jours postopératoires et la ligne de base (préopératoire)
|
entre 730 jours postopératoires et la ligne de base (préopératoire)
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Thomas Turgeon, MD, Orthopaedic Innovation Centre
- Directeur d'études: Branko Kopjar, MD, PhD, Nor Consult, LLC
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimé)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- HIT-001
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .