- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT04560634
Performance diastolique et norépinéphrine dans l'hypotension induite par la colonne vertébrale pour l'accouchement par césarienne (NORA-CS)
Influence de la performance diastolique sur la réponse à la noradrénaline pour la prévention de l'hypotension induite par la rachianesthésie pour l'accouchement par césarienne et le bien-être fœtal
Background and rationale: The best agent to prevent spinal-induced hypotension is still uncertain but norepinephrine showed fewer effects on heart rate and cardiac output. In septic patients norepinephrine has been shown to produce an "endogenous fluid challenge".
Objective: We aim to assess if patients with impaired diastolic function (46% of pregnant women at term) are less able to maintain indexed cardiac output in response to norepinephrine infusion during spinal-induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.
Methods: We will assess by echocardiogram the diastolic function before surgery and will then start continuous non-invasive hemodynamic monitoring with a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) and perform a fluid challenge to relate diastolic disfunction with fluid responsiveness. Hemodynamic monitoring will continue throughout the surgery. Norepinephrine infusion will start concomitantly to beginning of spinal anesthesia and will stop 5 minutes after uterotonic medication.
Outcome: We aim to assess if patients with diastolic disfunction are less able to maintain cardiac output in response to norepinephrine infusion during spinal anesthesia induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.)
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Italy
-
Rome, Italy, Italie, 00168
- IRCCS Fondazione Policlinico Universitario Agostino Gemelli
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
Pregnant women between the 36th and the 40th week of gestation undergoing spinal anesthesia for elective caesarian delivery.
Exclusion Criteria:
- age < 18 yo;
- preeclampsia;
- eclampsia;
- atrial fibrillation and sinus tachycardia;
- cardiovascular diseases;
- neuromuscular disease;
- emergent or urgent cesarean delivery;
- coagulopathies;
- contraindications to spinal anesthesia.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Science basique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Hemodynamic Assessment
All participants underwent the same protocol-specified procedures, including a 250-mL crystalloid fluid challenge and continuous non-invasive hemodynamic monitoring using ClearSight. Standard prophylactic norepinephrine was administered during spinal anesthesia for elective cesarean delivery. Participants were categorized according to left ventricular diastolic function (normal or impaired) for subsequent physiological analyses. No allocation to different treatments was performed. |
Norepinephrine is administered as a continuous infusion at 0.05 mcg/kg/min and is kept to maintain systolic blood pressure within 90-120% of baseline during spinal anaesthesia. The infusion is started at the same time cerebrospinal fluid is obtained, immediately before injection of spinal medications, through a small-bore tubing connected directly to the peripheral intravenous catheter. It is stopped 5 minutes All patients are connected to a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) by an inflatable finger cuff placed on the midphalanx of hand middle or ring finger with no radial artery catheter and its heart reference system (HRS) is zeroed at the level of the patient's midaxillary line. The ClearSight® monitoring is started in the pre-anaesthesia room and calibrated for 5 minutes before recording. The monitoring continues throughout the procedure until patient transfer in the recovery room. All data are anonymously collected on a USB pen for statistical analysis. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Indexed Cardiac Output
Délai: Baseline/after spinal anesthesia/after delivery
|
We aim to study if the diastolic performance of the heart measured by transthoracic echocardiography in healthy pregnant women at term undergoing spinal anesthesia for caesarean delivery influences the effects of norepinephrine on indexed cardiac output (CI) measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Indexed Stroke Volume
Délai: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of indexed stroke volume (SVI) in ml, blood pressure (BP) in mmHg and heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Systolic Blood Pressure
Délai: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of blood pressure (BP) in mmHg measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Heart Rate
Délai: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Apgar Scores
Délai: Decreases of Indexed Cardiac Output after spinal anesthesia
|
We ought to correlate the reduction of neonatal Apgar Scores with decreases of indexed cardiac output measured by non-invasive continuous hemodynamic monitoring. |
Decreases of Indexed Cardiac Output after spinal anesthesia
|
Collaborateurs et enquêteurs
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
- Maladies vasculaires
- Maladies cardiovasculaires
- Hypotension
- Produits chimiques organiques
- Hydrocarbures
- Hydrocarbures, cyclique
- Hydrocarbures, aromatique
- Amines
- Catéchols
- Phénols
- Dérivés de benzène
- Alcools
- Alcools amino
- Éthanolamines
- Monoamines biogéniques
- Amines biogéniques
- Catécholamines
- Norépinéphrine
Autres numéros d'identification d'étude
- 30865/19
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .