Diastolische prestaties en noradrenaline bij door de wervelkolom geïnduceerde hypotensie voor een keizersnede (NORA-CS)
Invloed van diastolische prestaties op de respons op norepinefrine voor preventie van door spinale anesthesie veroorzaakte hypotensie voor keizersnede en foetaal welzijn
Background and rationale: The best agent to prevent spinal-induced hypotension is still uncertain but norepinephrine showed fewer effects on heart rate and cardiac output. In septic patients norepinephrine has been shown to produce an "endogenous fluid challenge".
Objective: We aim to assess if patients with impaired diastolic function (46% of pregnant women at term) are less able to maintain indexed cardiac output in response to norepinephrine infusion during spinal-induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.
Methods: We will assess by echocardiogram the diastolic function before surgery and will then start continuous non-invasive hemodynamic monitoring with a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) and perform a fluid challenge to relate diastolic disfunction with fluid responsiveness. Hemodynamic monitoring will continue throughout the surgery. Norepinephrine infusion will start concomitantly to beginning of spinal anesthesia and will stop 5 minutes after uterotonic medication.
Outcome: We aim to assess if patients with diastolic disfunction are less able to maintain cardiac output in response to norepinephrine infusion during spinal anesthesia induced vasoplegia. We also aim to assess if fetal wellbeing is related to maternal cardiac output during spinal anesthesia for cesarean delivery.)
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
Italy
-
Rome, Italy, Italië, 00168
- IRCCS Fondazione Policlinico Universitario Agostino Gemelli
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
Pregnant women between the 36th and the 40th week of gestation undergoing spinal anesthesia for elective caesarian delivery.
Exclusion Criteria:
- age < 18 yo;
- preeclampsia;
- eclampsia;
- atrial fibrillation and sinus tachycardia;
- cardiovascular diseases;
- neuromuscular disease;
- emergent or urgent cesarean delivery;
- coagulopathies;
- contraindications to spinal anesthesia.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Fundamentele wetenschap
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Hemodynamic Assessment
All participants underwent the same protocol-specified procedures, including a 250-mL crystalloid fluid challenge and continuous non-invasive hemodynamic monitoring using ClearSight. Standard prophylactic norepinephrine was administered during spinal anesthesia for elective cesarean delivery. Participants were categorized according to left ventricular diastolic function (normal or impaired) for subsequent physiological analyses. No allocation to different treatments was performed. |
Norepinephrine is administered as a continuous infusion at 0.05 mcg/kg/min and is kept to maintain systolic blood pressure within 90-120% of baseline during spinal anaesthesia. The infusion is started at the same time cerebrospinal fluid is obtained, immediately before injection of spinal medications, through a small-bore tubing connected directly to the peripheral intravenous catheter. It is stopped 5 minutes All patients are connected to a ClearSight® monitor (ClearSight®, Edwards Lifescience, Irvine, CA) by an inflatable finger cuff placed on the midphalanx of hand middle or ring finger with no radial artery catheter and its heart reference system (HRS) is zeroed at the level of the patient's midaxillary line. The ClearSight® monitoring is started in the pre-anaesthesia room and calibrated for 5 minutes before recording. The monitoring continues throughout the procedure until patient transfer in the recovery room. All data are anonymously collected on a USB pen for statistical analysis. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Indexed Cardiac Output
Tijdsspanne: Baseline/after spinal anesthesia/after delivery
|
We aim to study if the diastolic performance of the heart measured by transthoracic echocardiography in healthy pregnant women at term undergoing spinal anesthesia for caesarean delivery influences the effects of norepinephrine on indexed cardiac output (CI) measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Indexed Stroke Volume
Tijdsspanne: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of indexed stroke volume (SVI) in ml, blood pressure (BP) in mmHg and heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Systolic Blood Pressure
Tijdsspanne: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of blood pressure (BP) in mmHg measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Heart Rate
Tijdsspanne: Baseline/after spinal anesthesia/after delivery
|
We will correlate diastolic performance measured by transthoracic echocardiography with the response to norepinephrine of heart rate (HR) in bpm measured by non-invasive continuous hemodynamic monitoring. |
Baseline/after spinal anesthesia/after delivery
|
|
Apgar Scores
Tijdsspanne: Decreases of Indexed Cardiac Output after spinal anesthesia
|
We ought to correlate the reduction of neonatal Apgar Scores with decreases of indexed cardiac output measured by non-invasive continuous hemodynamic monitoring. |
Decreases of Indexed Cardiac Output after spinal anesthesia
|
Medewerkers en onderzoekers
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 30865/19
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .