Enquête sur le cathéter à ballonnet de perfusion Ringer (Ringer PTCA)
Une étude prospective, multicentrique et à un seul bras du cathéter à ballonnet de perfusion Ringer (étude Ringer PTCA)
The objective of this study is to demonstrate safe and effective use of the Ringer perfusion balloon catheter for dilatation/pre-dilatation of coronary stenoses during percutaneous coronary intervention (PCI).
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
A prospective, multicenter, single-arm clinical study. The study will be conducted in 3 to 5 investigational sites in the US and Canada and will enroll up to 60 participants. The population for this study is adult participants undergoing non-emergent percutaneous coronary intervention (PCI) as a stand-alone procedure or following non-emergent diagnostic angiography performed during the same procedure.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Ontario
-
Scarborough Village, Ontario, Canada, M1B 4Z8
- Heart Health Institute
-
Toronto, Ontario, Canada, M5B 1W8
- St. Michael's Hospital
-
Toronto, Ontario, Canada, M4N3M5
- Sunnybrook Heath Sciences Center
-
-
-
-
California
-
Torrance, California, États-Unis, 90505
- Torrance Memorial Medical Center
-
-
Massachusetts
-
Boston, Massachusetts, États-Unis, 02115
- Brigham & Women's Hospital
-
-
Missouri
-
Kansas City, Missouri, États-Unis, 64111
- St. Luke's Hospital
-
-
Washington
-
Seattle, Washington, États-Unis, 98196
- University of Washington Medical Center
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Male and Female subjects >18 years old.
- Patients undergoing clinically indicated non-emergent PCI as a stand-alone procedure or in combination with diagnostic angiography during the same procedure.
- Study target lesion characteristics: a) native de-novo coronary stenosis of at least 70% visually estimated stenosis, or at least 50% visually estimated stenosis and shown to be physiologically significant by flow-mediated criteria (FFR <0.80, IFR <0.91); b) estimated reference vessel diameter 2.0-4.5mm; c) lesion length <25mm; d) calcification not greater than mild.
- Per investigator assessment, the patient may benefit from inflation distal perfusion during balloon inflation. Examples include, but are not limited to: (i) LV systolic dysfunction with LVEF<50% by any modality; (ii) a territory subtended by the target vessel downstream from the target lesion that is estimated to be in excess of 25% of viable LV mass; (iii) prior hemodynamic or electrical instablility during intervention on the target lesion; (iv) the potential to avoid placement of a coronary stent if a stent-like result can be achieved through prolonged balloon inflation.
- Female subjects of childbearing potential must have a negative pregnancy test per standard of care for PCI and be practicing contraception.
- Informed consent provided.
Exclusion Criteria:
- Hemodynamic or arrhythmic instability within 48 hours or a myocardial infarction within 72 hours of PCI.
- More than 2 lesions planned during index PCI.
- Procedural complication developing prior to PCI of study target.
- Ejection fraction (EF) <25%.
- Creatinine clearance (Cr-Cl) <25 mg/dL.
- Baseline flow at study target <TIMI-2.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Experimental
Adult subjects clinically indicated for non-emergent percutaneous coronary intervention (PCI) as a stand-alone procedure or following non-emergent diagnostic angiography performed during the same procedure that, in the physician's estimation, requires prolonged balloon inflation with distal perfusion. |
Non-emergent Percutaneous Coronary Intervention (PCI) for treatment of a coronary artery lesion with Ringer Perfusion Balloon Catheter. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Rate of Device Success in Dilatation/Pre-dilatation of Coronary Stenosis During PCI.
Délai: During Procedure
|
Procedure success defined as successful delivery of the Ringer PBC to and across the target lesion; Successful inflation and deflation of the Ringer (and subsequent removal); No vessel perforation, no flow-limiting vessel dissection, no reduction in TIMI flow from baseline, and no clinically significant arrhythmias requiring medical treatment or device intervention following dilatation with the Ringer; Achievement of a final TIMI flow grade of 3 at the conclusion of the PCI procedure for the lesion. |
During Procedure
|
|
Rate of Ringer Related Complications Arising During Device Delivery
Délai: Discharge or 30 days, whichever comes first
|
Rate of Ringer related complications arising during delivery, inflation or removal of Ringer; freedom from major cardiac adverse events (MACE) |
Discharge or 30 days, whichever comes first
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Number of Successful PCI
Délai: During Procedure
|
Final residual stenosis ≤20% diameter stenosis (in-stent) or ≤50% diameter stenosis (stand-alone balloon) by visual angiographic estimation and freedom from MACE. |
During Procedure
|
|
TIMI Flow During Ringer Balloon Inflation
Délai: During Procedure
|
Maintenance of TIMI-2 or -3 flow into distal coronary bed during Ringer inflation |
During Procedure
|
|
Tolerance of Ringer Inflation of Greater Than One Minutes
Délai: During Procedure
|
Tolerance of at least one Ringer inflation greater than one minute (prolonged inflation) at target site (measured with symptoms, ECG, hemodynamics). |
During Procedure
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Directeur d'études: Sherry Lane, Teleflex
- Chercheur principal: Kathleen Kearney, MD, University of Washington
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- ST3170
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .