- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT04862689
Investigação do Cateter Balão de Perfusão Ringer (Ringer PTCA)
Uma investigação prospectiva, multicêntrica e de braço único do cateter balão de perfusão Ringer (Estudo Ringer PTCA)
The objective of this study is to demonstrate safe and effective use of the Ringer perfusion balloon catheter for dilatation/pre-dilatation of coronary stenoses during percutaneous coronary intervention (PCI).
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
A prospective, multicenter, single-arm clinical study. The study will be conducted in 3 to 5 investigational sites in the US and Canada and will enroll up to 60 participants. The population for this study is adult participants undergoing non-emergent percutaneous coronary intervention (PCI) as a stand-alone procedure or following non-emergent diagnostic angiography performed during the same procedure.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Ontario
-
Scarborough Village, Ontario, Canadá, M1B 4Z8
- Heart Health Institute
-
Toronto, Ontario, Canadá, M5B 1W8
- St. Michael's Hospital
-
Toronto, Ontario, Canadá, M4N3M5
- Sunnybrook Heath Sciences Center
-
-
-
-
California
-
Torrance, California, Estados Unidos, 90505
- Torrance Memorial Medical Center
-
-
Massachusetts
-
Boston, Massachusetts, Estados Unidos, 02115
- Brigham & Women's Hospital
-
-
Missouri
-
Kansas City, Missouri, Estados Unidos, 64111
- St. Luke's Hospital
-
-
Washington
-
Seattle, Washington, Estados Unidos, 98196
- University of Washington Medical Center
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Male and Female subjects >18 years old.
- Patients undergoing clinically indicated non-emergent PCI as a stand-alone procedure or in combination with diagnostic angiography during the same procedure.
- Study target lesion characteristics: a) native de-novo coronary stenosis of at least 70% visually estimated stenosis, or at least 50% visually estimated stenosis and shown to be physiologically significant by flow-mediated criteria (FFR <0.80, IFR <0.91); b) estimated reference vessel diameter 2.0-4.5mm; c) lesion length <25mm; d) calcification not greater than mild.
- Per investigator assessment, the patient may benefit from inflation distal perfusion during balloon inflation. Examples include, but are not limited to: (i) LV systolic dysfunction with LVEF<50% by any modality; (ii) a territory subtended by the target vessel downstream from the target lesion that is estimated to be in excess of 25% of viable LV mass; (iii) prior hemodynamic or electrical instablility during intervention on the target lesion; (iv) the potential to avoid placement of a coronary stent if a stent-like result can be achieved through prolonged balloon inflation.
- Female subjects of childbearing potential must have a negative pregnancy test per standard of care for PCI and be practicing contraception.
- Informed consent provided.
Exclusion Criteria:
- Hemodynamic or arrhythmic instability within 48 hours or a myocardial infarction within 72 hours of PCI.
- More than 2 lesions planned during index PCI.
- Procedural complication developing prior to PCI of study target.
- Ejection fraction (EF) <25%.
- Creatinine clearance (Cr-Cl) <25 mg/dL.
- Baseline flow at study target <TIMI-2.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Experimental
Adult subjects clinically indicated for non-emergent percutaneous coronary intervention (PCI) as a stand-alone procedure or following non-emergent diagnostic angiography performed during the same procedure that, in the physician's estimation, requires prolonged balloon inflation with distal perfusion. |
Non-emergent Percutaneous Coronary Intervention (PCI) for treatment of a coronary artery lesion with Ringer Perfusion Balloon Catheter. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Rate of Device Success in Dilatation/Pre-dilatation of Coronary Stenosis During PCI.
Prazo: During Procedure
|
Procedure success defined as successful delivery of the Ringer PBC to and across the target lesion; Successful inflation and deflation of the Ringer (and subsequent removal); No vessel perforation, no flow-limiting vessel dissection, no reduction in TIMI flow from baseline, and no clinically significant arrhythmias requiring medical treatment or device intervention following dilatation with the Ringer; Achievement of a final TIMI flow grade of 3 at the conclusion of the PCI procedure for the lesion. |
During Procedure
|
|
Rate of Ringer Related Complications Arising During Device Delivery
Prazo: Discharge or 30 days, whichever comes first
|
Rate of Ringer related complications arising during delivery, inflation or removal of Ringer; freedom from major cardiac adverse events (MACE) |
Discharge or 30 days, whichever comes first
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Number of Successful PCI
Prazo: During Procedure
|
Final residual stenosis ≤20% diameter stenosis (in-stent) or ≤50% diameter stenosis (stand-alone balloon) by visual angiographic estimation and freedom from MACE. |
During Procedure
|
|
TIMI Flow During Ringer Balloon Inflation
Prazo: During Procedure
|
Maintenance of TIMI-2 or -3 flow into distal coronary bed during Ringer inflation |
During Procedure
|
|
Tolerance of Ringer Inflation of Greater Than One Minutes
Prazo: During Procedure
|
Tolerance of at least one Ringer inflation greater than one minute (prolonged inflation) at target site (measured with symptoms, ECG, hemodynamics). |
During Procedure
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Diretor de estudo: Sherry Lane, Teleflex
- Investigador principal: Kathleen Kearney, MD, University of Washington
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- ST3170
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .