Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

CT pour la ventilation mécanique personnalisée

4 novembre 2026 mis à jour par: The University of Texas Medical Branch, Galveston

Personalized Mechanical Ventilation to Minimize Ventilator-Induced Lung Injury Study

The goal of this study is to compare two different ways of helping patients with a condition called sepsis who need help breathing using a machine called a ventilator. The investigators want to study which way of setting the ventilator is better for the lungs.

Here are the main questions the investigators want to answer:

  1. How does the amount of air in the lungs and the way it moves differ between the two ways?
  2. How does the way air spreads out in different parts of the lungs differ between the two ways? In this study, the investigators will take special pictures of the lungs using a machine called a CT scan. The pictures will show us how much the lungs stretch and how much air is in different parts of the lungs. The investigators will compare two different ways of using the ventilator: one personalized for each patient based on their breathing, and another way that is commonly used.

By comparing these two ways, the investigators hope to learn which one is better for helping patients with sepsis who need the ventilator. This information can help doctors make better decisions about how to care for these patients and improve their breathing.

Aperçu de l'étude

Description détaillée

Mechanical ventilation is a key life support method applied to millions of surgical and critically ill patients. Ventilator-induced lung injury (VILI) is a major factor for morbidity and mortality in patients with the acute respiratory distress syndrome (ARDS), the most severe form of respiratory dysfunction. Furthermore, mechanical ventilation settings also contribute to the risk for postoperative pulmonary complications (PPCs) in surgical patients and lung injury in critically ill patients with normal lungs at onset of ventilation. In summary, mitigation of VILI is critical to reduce perioperative and critical care morbidity and mortality, with major impact on outcomes and health care costs.

In this project, we propose to apply novel CT methods to assess spatial distributions of strain and aeration and establish measures of global lung mechanics best indicative of the PEEP leading to least injurious distributions and, thus, least VILI.

Type d'étude

Interventionnel

Inscription (Réel)

7

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Texas
      • Galveston, Texas, États-Unis, 77555
        • The University of Texas Medical Branch

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Following onset of mechanical ventilation and not longer than 5 days after intubation.

  • Sepsis as defined by the most recent criteria:

    • Life-threatening organ dysfunction caused by a dysregulated host response to infection operationalized by presumed or documented infection and a Sequential [Sepsis-related] Organ Failure Assessment (SOFA) score >= 2 or a change by 2 from the baseline if baseline known to be different from 0;

Exclusion Criteria:

  • Age < 18 years;
  • Hemodynamic instability, defined as: systolic blood pressure (SBP) < 90 mmHg that is not adequately stabilized by vasopressors or inotropic agents. For these purposes, SBP will not be considered "adequately stabilized" if the dose of the vasopressor/inotrope has not been stable for at least one hour;
  • Hypoxemia, defined as: PaO2 < 70 mmHg on an inspired oxygen fraction (FiO2) greater than or equal to 0.9;
  • Hemodynamic and/or respiratory instability (as defined, in items 2 and 3) that develop when the patient is mobilized during routine nursing care such as repositioning/washing the patient or changing their bed linens;
  • Hemodynamic and/or respiratory instability (as defined, in items 2 and 3) that develop when a 20 second respiratory pause is required to implement the study protocol. This will be tested by inducing such a pause prior to transporting the patient;
  • Any acute or chronic condition which, in the opinion of the investigators, might confound the imaging measurements (such as, but not limited to, severe bronchospasm, pulmonary infection, and lung tumor);
  • Any acute or chronic condition which, in the opinion of the investigators or managing critical care team, could prevent safe transport to the CT suite.
  • "Air leaks" requiring tube thoracotomy (e.g., pneumothorax, bronchopleural fistula);
  • Body mass index > 40 kg/m2;
  • Pregnancy (since this is a study that would expose a fetus to radiation risk);
  • Patients who have taken part in other research studies involving radiation exposure, or those patients for whom this research radiation history is unavailable at the time of consent.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: La prévention
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Seul

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Comparateur actif: Group 1: ARDSNet

Participants will receive standard ARDSNet low-stretch PEEP (positive end-expiratory pressure) protocol.

Breathing assistance from the breathing assist machine using the pressure settings typical for your disease.

Standard ARDSNet low-stretch PEEP (positive end-expiratory pressure) protocol: PEEP will be set following a routinely used PEEP table according to patients' blood oxygenation status.

Expérimental: Group 2: Individualized PEEP (positive end expiratory pressure) Strategy

Participants will receive individualized PEEP (positive end-expiratory pressure).

Breathing assistance from the breathing assist machine using a method in which doctors try to find the pressures that expands the lungs the best. This is based on measurements of one's respiratory pressures and volumes. This is done by adjusting the pressure settings. This allows one's lungs to expand with the least amount of change in pressure during breathing.

PEEP (positive end-expiratory pressure) will be set at the maximum static respiratory system compliance (Crs) during a descending PEEP titration curve.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Squared coefficient of variation of the tidal volumetric strain
Délai: 48 hours

Squared coefficient of variation (=variance normalized by the squared mean) of the tidal volumetric strain will be obtained and calculated from CT images.

48 hours

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Squared coefficient of variation of aeration
Délai: 48 hours

Squared coefficient of variation (=variance normalized by the squared mean) of aeration obtained and calculated from CT images.

48 hours
Average gas fraction
Délai: 48 hours

Average gas fraction will be obtained and calculated from CT images.

48 hours
Distribution of aeration categories
Délai: 48 hours

Distribution of aeration categories (non-aerated, poorly aerated, normally aerated and hyperinflated regions) will be obtained and calculated from CT images.

48 hours
Average tidal strain
Délai: 48 hours

Average of voxel level volumetric tidal strain will be obtained and calculated from CT images.

48 hours

Autres mesures de résultats

Mesure des résultats
Description de la mesure
Délai
Time during mechanical ventilation
Délai: Up to 5 days

Time during mechanical ventilation will be recorded in days.

Up to 5 days
Detection of Inflammatory cytokines
Délai: 48 hours

Inflammatory cytokine is a type of signaling molecule (a cytokine) that is secreted from immune cells like helper T cells (Th) and macrophages, and certain other cell types that promote inflammation; their presence will be measured by assays.

48 hours

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Marcos Vidal Melo, MD, PhD, University of Texas

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

10 mai 2023

Achèvement primaire (Estimé)

31 août 2027

Achèvement de l'étude (Estimé)

31 août 2027

Dates d'inscription aux études

Première soumission

28 juillet 2023

Première soumission répondant aux critères de contrôle qualité

28 juillet 2023

Première publication (Réel)

4 août 2023

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

6 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

4 novembre 2026

Dernière vérification

1 novembre 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Description du régime IPD

This is a NIH funded study. Data sharing will follow NIH guidelines.

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner