- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT06705257
Effet de différents niveaux de PEP sur le recrutement pulmonaire prématuré à l'aide de la tomographie par impédance électrique - Étude de faisabilité ([PEOPLE])
EFFET de DIFFÉRENTS NIVEAUX de PEP sur le RECRUTEMENT PULMONAIRE PRÉTERME À L'AIDE DE L'ÉTUDE DE FAISABILITÉ DE L'EIT
Babies born early (under 32 weeks) are at risk of developing lung problems after birth. A major reason for this is that the lungs are not fully developed. Lungs of preterm babies will often collapse in between breathing due to lung immaturity. Applying gentle pressure, using nasal device through their nostril or through the breathing tube helps to prevent this lung collapse. This would help in air-oxygen going to lungs and also makes the babies breathing more comfortable. This gentle pressure is medically called as PEEP/CPAP and could be delivered by breathing machine (ventilator) and CPAP machine, collectively called as "continuous distending pressure (CDP)".
Those babies breathing on their own and receiving inadequate CDP would need more breathing support by placing them on breathing machine (ventilator). The longer the baby receives breathing machine support, higher chance of lung injury . Preterm infants who are already on breathing machine, providing sub optimal PEEP/CPAP could also lead to lung damage. Providing optimal PEEP/CPAP could prevent these negative outcomes. Currently there is not enough evidence to suggest optimal PEEP/CPAP in preterm infants. Neonatal units all around the world uses PEEP/CPAP ranging from 4 to 10cm H20 based on their unit practice. Currently available investigations provide limited one time information (e.g. Chest X-ray) regarding whether baby is receiving optimal PEEP/CPAP. Electrical Impedance Tomography (EIT) is a new technology which could provide better information regarding the pressure delivered. Also, this device would provide continuous information as if the clinicians are doing continuous chest X-ray but without any radiation. In this study, the team will assess the effect of different levels of PEEP/CPAP (4 to 10cm H20) on prevention of lung collapse using EIT. This would be studied in premature infants who are on breathing machine support and CPAP machine support.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Prakash Kannan Loganathan, MD
- Numéro de téléphone: +447481492632
- E-mail: pkannanloganathan@nhs.net
Sauvegarde des contacts de l'étude
- Nom: Amanda Forster
- Numéro de téléphone: +44 1642 854872
- E-mail: amanda.forster2@nhs.net
Lieux d'étude
-
-
-
Middlesbrough, Royaume-Uni
- Recrutement
- South Tees NHS Trust
-
Contact:
- Prakash Logananthan
- E-mail: pkannanloganathan@nhs.net
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion criteria
- Gestational age <32 weeks based on mother's last menstrual period or first trimester ultrasound dating.
- Receiving either CPAP or mechanical ventilation respiratory support.
- Informed written consent from one of the parents.
- Within the first two weeks of life. Investigators pragmatically chose this period, as there could be considerable lung injury after the first two weeks of life, making it difficult to test our hypothesis. Also, this time period would allow parents to settle down with their stressful preterm delivery and investigators could approach anytime within the first two weeks of life.
Exclusion criteria
- Major congenital malformations including congenital lung disease and congenital heart disease as ascertained by the medical team.
- Infants diagnosed with pneumothorax i.
- Receiving high frequency mechanical ventilation.
- Infants with concerns of skin integrity.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Un seul bras avec des niveaux de PEP croissants et décroissants
|
Feasibility of using EIT, to study the effect of varying levels of PEEP/Continous distending pressure on lung recruitment as measured by changes in functional lung scores and silent spaces in preterm infants (<32 weeks) who are on mechanical ventilation or receiving primary or post extubation CPAP support. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Changes in EIT parameters
Délai: total study of 280 minutes
|
Changes in End expiratory Lung Impedance scores |
total study of 280 minutes
|
|
Changes in EIT parameters
Délai: 280minutes
|
Changes in functional lung scores in percentage varying levels of CDP. |
280minutes
|
|
Changes in EIT
Délai: 280 minutes
|
Changes in silence spaces with varying levels of CDP. |
280 minutes
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Secondary outcomes
Délai: Total 280 minutes of study time
|
Changes in oxygen saturation (SpO2 in percentage) during the study period. |
Total 280 minutes of study time
|
|
Secondary outcome measure
Délai: Total study time of 280 minutes
|
Changes in carbon dioxide levels as measured by transcutaneous carbon dioxide levels (TCO2) in kilopascal. |
Total study time of 280 minutes
|
|
Secondary outcome
Délai: Total study time of 280 minutes
|
Changes in fraction of inspiratory oxygen (Fio2) levels during the study. |
Total study time of 280 minutes
|
|
Secondary outcome
Délai: Total study time of 280minutes
|
Changes in blood pressure (if measured) during the study procedure. |
Total study time of 280minutes
|
Collaborateurs et enquêteurs
Les enquêteurs
- Directeur d'études: Jackie Mitchell, South Tees NHS foundation trust
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- IRAS [340081] - [PEOPLE]
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Délai de partage IPD
After the main study publication
Critères d'accès au partage IPD
With valid study protocol and ethical approval.
Type d'informations de prise en charge du partage d'IPD
- PROTOCOLE D'ÉTUDE
- SÈVE
- CIF
- ANALYTIC_CODE
- RSE
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .