- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT06925477
SLT direct vs conventionnel dans le glaucome à angle ouvert: un RCT
Un essai contrôlé randomisé comparant la trabéculoplastie laser sélective directe (DSLT) et la trabéculoplastie laser sélective (SLT) dans la réduction de la pression intraoculaire dans le glaucome à angle ouvert
This study compares two laser treatments for open-angle glaucoma: Selective Laser Trabeculoplasty (SLT) and Direct Selective Laser Trabeculoplasty (DSLT). SLT is a widely used procedure that requires a manual technique with a goniolens, while DSLT is a new, automated, non-contact method using the Eagle system. The study will evaluate whether DSLT is as effective as SLT in reducing intraocular pressure (IOP). Participants will be randomly assigned to receive either treatment and will be monitored over 12 months to assess changes in IOP, medication use, and safety outcomes. The goal is to determine if the simpler DSLT procedure can provide similar results to SLT, potentially improving patient comfort and access to glaucoma care.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Glaucoma management is fundamentally aimed at reducing intraocular pressure (IOP) to prevent optic nerve damage and preserve vision. Selective Laser Trabeculoplasty (SLT) has been a cornerstone in the treatment of open-angle glaucoma due to its efficacy and safety profile. However, SLT's manual delivery method using a goniolens can introduce variability, patient discomfort, and operator dependency.
Direct Selective Laser Trabeculoplasty (DSLT) represents an innovative advancement, offering a non-contact, automated laser treatment via the Eagle system. This technology is designed to simplify the procedure, enhance patient comfort, and minimize operator-induced variability. Early evidence suggests that DSLT may provide similar or improved IOP reduction compared to SLT, with a potentially better safety profile.
This study seeks to rigorously evaluate whether DSLT is non-inferior to SLT in reducing IOP, thus providing critical data on the efficacy and safety of this novel approach. Demonstrating non-inferiority would support broader adoption of DSLT, potentially improving patient outcomes and expanding access to effective glaucoma treatment.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
South Carolina
-
Charleston, South Carolina, États-Unis, 29407
- MUSC Health West Ophthalmology Clinic
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
-
Age ≥18 years.
-
Diagnosed with OAG (including exfoliative/pigmentary glaucoma) or OHT.
-
Gonioscopically visible scleral spur for 360 degrees.
-
Ability to provide informed consent.
-
In good health, without prior laser trabeculoplasty, with decision to treat made by an ophthalmologist on the basis of risk profile, patient preference, or both.
-
Each eye with one of the following qualifying diagnoses (diagnoses may differ between eyes):
- High-risk ocular hypertension (OHT): IOP > 21 mmHg without glaucomatous optic neuropathy (excavation, diffuse or focal thinning or notching of the neuroretinal rim, visible nerve fiber layer defects, or asymmetry of the vertical cup-to-disc ratio of >0.2 between eyes) [enrollment of trial participants with High-risk OHT will be capped at 25% of total enrollment]
- Mild primary open-angle glaucoma: glaucomatous optic neuropathy, visual field mean deviation >-6.0 dB with no points in the central 5° <15 dB
- Moderate primary open-angle glaucoma: glaucomatous optic neuropathy, visual field mean deviation -6.0 dB to >-12 dB and no more than 1 central 5° point <15 dB
Exclusion Criteria:
- Advanced POAG in either eye
- Glaucoma other than OAG (including pigmentary and pseudoexfoliation glaucoma) in either eye
- Mean IOP > 35 mmHg at either the screening or baseline visit in either eye
- Narrow or closed angle (Shaffer Grade 0, 1, or 2) in either eye
- Contraindications to SLT, brimonidine, apraclonidine, or any other study intervention
- Any corneal pathology that would preclude accurate assessment of IOP by Goldmann tonometry in either eye
- Any intraocular surgical procedure within the past 6 months in either eye
- Inability to attend all scheduled study visits
- Pregnancy or plan to become pregnant in the next 1 year
- Any prior laser trabeculoplasty, including ALT, MLT and SLT.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Autre: Arm 1- DSLT (Direct Selective Laser Trabeculoplasty)
DSLT is a well-established non-contact laser application that does not require a gonioscopy lens, reducing the risk of corneal damage and inflammation. |
This intervention aims to determine the efficacy and safety of Direct Selective Laser Trabeculoplasty (DSLT) in reducing intraocular pressure in patients with open-angle glaucoma. |
|
Autre: Arm 2- Selective Laser Trabeculoplasty (SLT)
SLT is a widely used and effective laser therapy to lower intraocular pressure that requires operator expertise and carries risks of mild inflammation, corneal damage and discomfort. This is a standard laser system that requires the use of a gonioscopy lens placed on the cornea to administer. |
To determine the efficacy and safety of using Selective Laser Trabeculoplasty for treatment of open-angle glaucoma. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Primary Endpoint
Délai: 6 months
|
Measuring the difference in the average IOP measurement reduction from the patient's baseline at 6 months between the DSLT and the SLT groups. |
6 months
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Secondary Outcome
Délai: 12 months
|
The patients percentage of IOP reduction at 2 months, 6 months, and 12 months. Measuring the amount of patient's that have achieved >/= 20% IOP reduction at 6 months. Documentation of any change in the use of ocular hypotensive medications at 12 months. Documentation of the rate of repeat laser treatments or additional IOP lowering procedures. |
12 months
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Jella An, MD, MBA, Medical University of South Carolina
Publications et liens utiles
Publications générales
- Konstantakopoulou E, Gazzard G, Garway-Heath D, Adeleke M, Ambler G, Vickerstaff V, Bunce C, Nathwani N, Barton K; LiGHT Trial Study Group. Selective Laser Trabeculoplasty After Medical Treatment for Glaucoma or Ocular Hypertension. JAMA Ophthalmol. 2025 Apr 1;143(4):295-302. doi: 10.1001/jamaophthalmol.2024.6492.
- Goldenfeld M, Belkin M, Dobkin-Bekman M, Sacks Z, Blum Meirovitch S, Geffen N, Leshno A, Skaat A. Automated Direct Selective Laser Trabeculoplasty: First Prospective Clinical Trial. Transl Vis Sci Technol. 2021 Mar 1;10(3):5. doi: 10.1167/tvst.10.3.5.
- Melik Parsadaniantz S, Reaux-le Goazigo A, Sapienza A, Habas C, Baudouin C. Glaucoma: A Degenerative Optic Neuropathy Related to Neuroinflammation? Cells. 2020 Feb 25;9(3):535. doi: 10.3390/cells9030535.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- Pro00142923
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .