- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07553273
Anesthésie vibratoire sur la douleur suite à des injections de corticostéroïdes
L'effet de l'anesthésie vibratoire sur la perception de la douleur chez les patients lors d'injections de corticostéroïdes au membre supérieur
This research study aims to evaluate injectional pain at the site of needle insertion for corticosteroid injections (CSI) of the upper extremity depending on different modes of anesthetics. Each individual's perception of pain upon receiving a CSI with two out of three modes of anesthesia (control/no anesthesia, vibrational anesthesia, vapo-coolant anesthesia) will be utilized to compare these variables and determine the method that is associated with the least pain.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
As part of standard medical care, participants receive corticosteroid injections to the bilateral upper extremities. Following written informed consent, participants undergo the study procedures described below. Each participant receives a total of two injections, with one injection administered in each arm during a single study visit.
The type of anesthesia used for each injection is determined by random assignment using a computer-generated randomization sequence within the REDCap system. Participants are assigned to one of the following anesthesia combinations:
No anesthesia and vapocoolant spray topical anesthetic applied prior to injection No anesthesia and vibration anesthesia using the DigiVibe device throughout the duration of the injection Vapocoolant spray topical anesthetic applied prior to injection combined with vibration anesthesia using the DigiVibe device throughout the duration of the injection
For participants assigned to a DigiVibe group, the device is applied directly to the skin. The device contains a circular component that contacts the skin surface and provides vibratory stimulation. The injection is administered within the circular area while vibration is applied.
Upon completion of each injection, participants complete a numeric pain rating scale to assess perceived pain and comfort associated with the anesthesia method used.
Both corticosteroid injections are administered as part of routine clinical care. The use of topical anesthetic and/or vibratory anesthesia is performed solely for research purposes. The total duration of the study visit is approximately 20 minutes.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: John Faillace, MD,FAAOS
- Numéro de téléphone: 409-772-1011
- E-mail: jofailla@utmb.edu
Sauvegarde des contacts de l'étude
- Nom: Alice Lee
- Numéro de téléphone: 409-772-1011
- E-mail: alklee@utmb.edu
Lieux d'étude
-
-
Texas
-
Galveston, Texas, États-Unis, 77555
- Recrutement
- University of Texas Medical Branch
-
Contact:
- Alice Lee
- Numéro de téléphone: 409-772-1011
- E-mail: alklee@utmb.edu
-
Contact:
- John Faillace, MD, FAAOS
- Numéro de téléphone: (409)772-1011
- E-mail: jofailla@utmb.edu
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Any patient of the Principal Investigator who has clinically diagnosed bilateral arthritis, tendinopathy, arthropathy, or compression neuropathy of the hand, wrist, or elbow where treatment with corticosteroid injection is indicated.
- Participants who voluntarily consent to participate in the study and sign consent forms.
- Participants who complete all numeric pain rating scales
- Patients aged ≥ 18 years old
Exclusion Criteria:
- Participants who opt out of the study or withdraw consent
- Participants who are determined to be without capacity to consent to study participation or injection procedure by principal investigator
- Participants with inability to complete numeric pain rating scales
- Participants with known allergies to triamcinolone acetonide, lidocaine, or bupivicaine
- Participants without clinically diagnosed bilateral arthritis, tendinopathy, arthropathy, or compression neuropathy of the hand, wrist, or elbow.
- Participants where treatment with corticosteroid injection is not indicated bilaterally.
- Patients ≤ 18 years old
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Soins de soutien
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Aucune intervention: Limb A: No Anesthesia and Limb B: Vapocoolant Spray Anesthesia
No anesthesia and vapocoolant spray topical anesthetic prior to injection. Participant will complete post-injection numeric pain rating scale assessing pain of injection. |
|
|
Expérimental: Limb A: No Anesthesia and Limb B:Vibration Anesthesia (DigiVibe)
Limb A: no anesthesia and Limb B:vibration anesthesia using the Digivibe device throughout the duration of the injection. Vibratory anesthesia will be administered throughout the duration of the injection. The circular part of the device will be applied directly to the surface of the skin. At the center of the circle is where the injection will be given, and the vibration will be turned on throughout the duration of the injection. After typical disposal of injection syringe, participant will complete post-injection numeric pain rating scale assessing pain of injection. |
The Digivibe device uses pulsed vibrations to activate larger nerve fibers to interfere with pain signals. It has a circular shape to allow for injections in an area surrounded by pain-blocking vibrations. |
|
Expérimental: Limb A: Vapocoolant Spray Anesthesia Limb B: Vibration Anesthesia (DigiVibe)
Limb A: vapocoolant spray topical anesthetic prior to injection and Limb B: vibration anesthesia using the Digivibe device throughout the duration of the injection Vapocoolant spray anesthesia will be applied until the skin blanches, which is the standard clinical use. Corticosteroid injection will be given. After typical disposal of injection syringe, participant will complete post-injection numeric rating score. |
The Digivibe device uses pulsed vibrations to activate larger nerve fibers to interfere with pain signals. It has a circular shape to allow for injections in an area surrounded by pain-blocking vibrations. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Pain Intensity During Corticosteroid Injection With Topical Anesthesia in the Hand
Délai: At time of injection (immediately following corticosteroid injection procedure)
|
Pain intensity will be assessed using a validated pain scale (e.g., 0-10 Numeric Rating Scale [NRS]) at the time of corticosteroid injection in the hand, wrist, or elbow. (0 being none 10 being worst possible pain) |
At time of injection (immediately following corticosteroid injection procedure)
|
|
Pain Intensity During Corticosteroid Injection With Topical Anesthesia in the Elbow
Délai: At time of injection (immediately following corticosteroid injection procedure)
|
Pain intensity will be assessed using a validated pain scale (e.g., 0-10 Numeric Rating Scale [NRS]) at the time of corticosteroid injection in the hand, wrist, or elbow. (0 being none 10 being worst possible pain) |
At time of injection (immediately following corticosteroid injection procedure)
|
|
Pain Intensity During Corticosteroid Injection With Topical Anesthesia in the Wrist
Délai: At time of injection (immediately following corticosteroid injection procedure)
|
Pain intensity will be assessed using a validated pain scale (e.g., 0-10 Numeric Rating Scale [NRS]) at the time of corticosteroid injection in hand, wrist, or elbow. (0 being none 10 being worst possible pain) |
At time of injection (immediately following corticosteroid injection procedure)
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Change in Pain Intensity From Baseline to Injection in the Arm
Délai: Baseline (pre-injection) to time of injection
|
Change in participant-reported pain intensity will be calculated as the difference between baseline pain (prior to injection) and pain during injection using a 0-10 Numeric Rating Scale (NRS), where 0 indicates no pain and 10 indicates the worst possible pain. Scores will be compared across intervention groups (vibratory anesthesia, vapocoolant spray anesthesia, and no anesthesia). |
Baseline (pre-injection) to time of injection
|
|
Change in Pain Intensity From Baseline to Injection in the Elbow
Délai: Baseline (pre-injection) to time of injection
|
Change in participant-reported pain intensity will be calculated as the difference between baseline pain (prior to injection) and pain during injection using a 0-10 Numeric Rating Scale (NRS), where 0 indicates no pain and 10 indicates the worst possible pain. Scores will be compared across intervention groups (vibratory anesthesia, vapocoolant spray anesthesia, and no anesthesia). |
Baseline (pre-injection) to time of injection
|
|
Change in Pain Intensity From Baseline to Injection in the Wrist
Délai: Baseline (pre-injection) to time of injection
|
Change in participant-reported pain intensity will be calculated as the difference between baseline pain (prior to injection) and pain during injection using a 0-10 Numeric Rating Scale (NRS), where 0 indicates no pain and 10 indicates the worst possible pain. Scores will be compared across intervention groups (vibratory anesthesia, vapocoolant spray anesthesia, and no anesthesia). |
Baseline (pre-injection) to time of injection
|
Collaborateurs et enquêteurs
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 24-0303
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .