Effetto delle istruzioni per la rianimazione cardiopolmonare con assistenza telefonica ottimizzate con AED sul tempo di non-flusso e sulla frazione di compressioni toraciche
Effetto delle Istruzioni per la RCP Telefonica Ottimizzate con AED sul Tempo di Non-flusso e sulla Frazione di Compressione Toracica in uno Scenario di Arresto Cardiaco con Singolo Soccorritore - Uno Studio di Simulazione Randomizzato-controllato
Out-of-hospital cardiac arrest (OHCA) remains a leading cause of mortality worldwide, with survival highly dependent on the immediate initiation of bystander cardiopulmonary resuscitation (CPR). Early recognition, prompt chest compressions, and rapid defibrillation are critical components of the chain of survival. Telephone-assisted CPR (T-CPR) provided by emergency dispatchers has been shown to significantly increase bystander intervention rates and improve outcomes. While the availability and use of automated external defibrillators (AEDs) further enhance survival, the optimal integration of AED use into dispatcher-guided, single-rescuer scenarios remains insufficiently studied.
This prospective, randomized, controlled simulation study aims to evaluate the effect of modified telephone cardiopulmonary resuscitation (T-CPR) instructions optimized for automated external defibrillator (AED) use on no-flow time and chest compression fraction (CCF) during single-rescuer resuscitation. Participants are randomized to receive either standard T-CPR instructions or enhanced instructions focusing on minimizing interruptions in chest compressions and reducing time to first compression during AED use.
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Out-of-hospital cardiac arrest (OHCA) is a major public health problem associated with low survival rates despite advances in emergency care systems. Survival is critically dependent on early recognition, immediate initiation of high-quality chest compressions, and timely defibrillation. Bystander intervention plays a pivotal role in this process, and telephone-assisted cardiopulmonary resuscitation (T-CPR) has been demonstrated to substantially increase the likelihood of CPR initiation prior to the arrival of emergency medical services.
The increasing availability of automated external defibrillators (AEDs) in public spaces has further strengthened the chain of survival. Early defibrillation is a key determinant of favorable outcomes, particularly in shockable rhythms. However, the integration of AED use into dispatcher-assisted scenarios - especially when only a single rescuer is present - poses practical challenges. In such situations, the rescuer must balance multiple tasks, including chest compressions, AED retrieval, device preparation, and adherence to voice prompts, all of which may introduce interruptions in compressions and increase no-flow time.
While the benefits of T-CPR and AED use independently are well established, there is limited evidence on how dispatcher instructions can optimally coordinate these interventions in single-rescuer scenarios. In particular, it remains unclear whether modified, AED-optimized T-CPR instructions can reduce no-flow time and improve chest compression fraction (CCF) by minimizing unnecessary interruptions and optimizing task sequencing.
This prospective, randomized, controlled simulation study aims to evaluate the effect of modified telephone cardiopulmonary resuscitation (T-CPR) instructions optimized for automated external defibrillator (AED) use on no-flow time and chest compression fraction (CCF) during single-rescuer resuscitation. Participants are randomized to receive either standard T-CPR instructions or enhanced instructions focusing on minimizing interruptions in chest compressions and reducing time to first compression during AED use.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Pécs, Ungheria, 7621
- University of Pécs
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Adolescents and adults (≥16 years)
- Healthcare professionals or laypersons
- Voluntary participation
Exclusion Criteria:
- pregnant women
- people with cardio-pulmonary and musculoskeletal diseases or any other impairment that would risk harm for the volunteer while performing CPR
- physical and/or psychological disabilities
- technical issue during data collection
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Triplicare
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Standard T-CPR
Participants perform dispatcher-assisted CPR based on the European Resuscitation Council (ERC) 2025 guidelines and the national standard DA-CPR protocol. |
Participants receive structured telephone CPR instructions reflecting current national practice. AED retrieval is instructed early; however, no additional guidance is provided to optimize timing or minimize interruptions during AED use. |
|
Comparatore attivo: AED-optimized T-CPR
Participants perform dispatcher-assisted CPR based on the European Resuscitation Council (ERC) 2025 guidelines and a modified national DA-CPR protocol. |
Participants receive standard T-CPR instructions supplemented with specific guidance aimed at:
Key elements include:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
No-flow time
Lasso di tempo: During procedure.
|
Time without chest compressions measured from entry into the simulation (collapse recognition) until termination of the scenario (giving the third shock). |
During procedure.
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Time to first chest compression
Lasso di tempo: During procedure.
|
The time (in seconds) until the first chest compression (measured from entering the scenario). |
During procedure.
|
|
Time to first shock
Lasso di tempo: During procedure
|
The time to the first shock by the AED (in seconds, from the time of entering the scenario). |
During procedure
|
|
Chest compression fraction
Lasso di tempo: During procedure.
|
Proportion of time during which chest compressions are performed (until giving the third shock), calculated from the first chest compression until scenario termination. |
During procedure.
|
|
Peri-shock pause
Lasso di tempo: During procedure
|
The time without chest compression (in seconds) before and after giving the shock. |
During procedure
|
Altre misure di risultato
Altre misure di risultato
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Attitude about T-CPR instructions
Lasso di tempo: Immediately after the CPR procedure (within 15 minutes)
|
Subjective feelings after performing cardiopulmonary resuscitation based on a short survey using Likert-scale based queries (1-4 points, lower numbers indicate worse, higher score indicates better opinion). |
Immediately after the CPR procedure (within 15 minutes)
|
Collaboratori e investigatori
Sponsor
Sponsor
Pubblicazioni e link utili
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Effettivo)
Completamento primario
Completamento dello studio (Effettivo)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- DA-CPR and AED
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
De-identified individual participant data underlying the results reported in publications arising from this study may be made available to qualified researchers upon reasonable request. The shared data may include participant-level demographic characteristics and de-identified CPR performance (time-related and quality relatad) and subjective outcome data collected during the study.
Periodo di condivisione IPD
Beginning upon publication of the primary results of the study and with no planned end date.
Criteri di accesso alla condivisione IPD
Data may be requested from the corresponding author for scientifically justified research purposes. Requests will be reviewed by the research team and will be considered subject to applicable ethical, legal, and data protection requirements. Data may only be shared in a de-identified form and subject to appropriate conditions for data use.
Tipo di informazioni di supporto alla condivisione IPD
- STUDIO_PROTOCOLLO
- ICF
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .