Application of CT-Linac-Based "All-in-One" One-Stop Radiotherapy in Breast Cancer
Application of CT-Linac-Based "All-in-One" One-Stop Radiotherapy in All-Scenario Breast Cancer Radiotherapy: A Prospective Clinical Study
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Tipo di studio
Tipo di studio
Iscrizione (Stimato)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
Contatto studio
- Nome: Xiaoli Yu, MD, PhD
- Numero di telefono: +86-021-64175590
- Email: xiaoliyu@fudan.edu.cn
Backup dei contatti dello studio
- Nome: Xiaofang Wang, MD, PhD
- Numero di telefono: +86 18017317247
- Email: xiaofang0708@yeah.net
Luoghi di studio
-
-
Shanghai Municipality
-
Shanghai, Shanghai Municipality, Cina, 200032
- Reclutamento
- Fudan University Shanghai Cancer Center
-
Contatto:
- Xiaofang Wang Wang
- Numero di telefono: +86 18017317247
- Email: xiaofang0708@yeah.net
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria:
- Histologically or pathologically confirmed breast cancer with definitive indications for radiotherapy (preoperative, postoperative, or radical)
- ECOG performance status of 0-2
- Able to remain still and supine on the treatment couch for up to 30 minutes
- Provision of signed, written informed consent
- Able to comply with daily follow-ups and blood sample collections
Exclusion Criteria:
- Palliative radiotherapy for concurrent distant metastasis
- Incomplete or ongoing chemotherapy
- Synchronous multiple primary tumors
- Current pregnancy or lactation
- Prior history of radiotherapy to the ipsilateral breast, chest wall, thorax, or regional lymph nodes
- Severe non-malignant comorbidities (e.g., cardiovascular or pulmonary diseases, systemic lupus erythematosus, scleroderma) resulting in a short life expectancy or inability to tolerate radical radiotherapy
- Inability or unlikelihood to comply with study follow-up
- Inability or unwillingness to provide written informed consent
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Altro
- Assegnazione: Non randomizzato
- Modello interventistico: Assegnazione sequenziale
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Altro: ARM1: AI-empowered AIO WBI
Evaluates the feasibility, safety, and patient experiences of the AI-empowered AIO workflow in breast cancer patients undergoing whole-breast irradiation (WBI) without regional nodal involvement.
|
The workflow relies on specialized convolutional neural networks for automated segmentation and dose-prediction auto-planning.
These breast cancer models were trained on 285 historical institutional cases spanning radical mastectomy and breast-conserving surgery over five years.
Auto-delineated structures include the clinical target volume, regional lymph nodes (if involved), tumor bed (identified by surgical clips), heart, bilateral lungs, unaffected breast, spinal cord, esophagus, thyroid, and affected humeral head.
These contours guide dose prediction to generate deliverable tangential arc plans via clinical-goal-guided automated optimization in the treatment planning system.
To adapt to the on-couch treatment scenario, models were validated on retrospective data and offline routines to maximize target delineation accuracy and the first-approval rate of auto-plans.
|
|
Altro: ARM2: Expanded-Scenario AIO RT
Evaluates the feasibility, safety, and patient experiences of the AI-empowered AIO workflow in breast cancer patients with broader radiotherapy indications, including breast/chest wall irradiation with or without regional nodal radiotherapy.
|
The workflow relies on specialized convolutional neural networks for automated segmentation and dose-prediction auto-planning.
These breast cancer models were trained on 285 historical institutional cases spanning radical mastectomy and breast-conserving surgery over five years.
Auto-delineated structures include the clinical target volume, regional lymph nodes (if involved), tumor bed (identified by surgical clips), heart, bilateral lungs, unaffected breast, spinal cord, esophagus, thyroid, and affected humeral head.
These contours guide dose prediction to generate deliverable tangential arc plans via clinical-goal-guided automated optimization in the treatment planning system.
To adapt to the on-couch treatment scenario, models were validated on retrospective data and offline routines to maximize target delineation accuracy and the first-approval rate of auto-plans.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Acute adverse events
Lasso di tempo: 6 months
|
The incidence and severity of acute adverse event include radiation dermatitis, pruritus, skin pain, radiation esophagitis, and radiation pneumonitis.
|
6 months
|
Misure di risultato secondarie
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Accuracy
Lasso di tempo: 2 months
|
Auto-segmentation accuracy was assessed by comparing automatically generated contours against the final physician-approved contours
|
2 months
|
|
Success rate
Lasso di tempo: 2 months
|
Record AIO workflow success rate: online planning one-pass optimization success rate.
|
2 months
|
|
Quality of life (QoL)
Lasso di tempo: 6 months
|
Quality of life will be evaluated via standardized QoL scales.
|
6 months
|
|
Time efficiency
Lasso di tempo: 2 months
|
The time efficiency of the workflow was automatically recorded by the system
|
2 months
|
|
Full-Workflow Patient Intrafraction Motion
Lasso di tempo: 2 months
|
Evaluated based on geometric deviations between pretreatment image-guided radiotherapy (IGRT), posttreatment imaging, and the baseline simulation CT
|
2 months
|
|
Correlation of Patient Metrology with Setup Error and Dosimetric Performance
Lasso di tempo: 2 months
|
Evaluation of how Body Mass Index (BMI) and weight fluctuations correlate with geometric setup errors and in vivo gamma pass rates
|
2 months
|
|
Correlation of Anatomical Scale with Setup Error and Dosimetric Performance
Lasso di tempo: 2 months
|
Evaluation of how anatomical scale/breast size correlates with geometric setup errors and in vivo gamma pass rates
|
2 months
|
Collaboratori e investigatori
Sponsor
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- FDRT-BC029
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Tipo di informazioni di supporto alla condivisione IPD
- STUDIO_PROTOCOLLO
- ICF
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .