- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT06077513
Confronto tra strutture Ti-Mesh per l'aumento dell'osso alveolare
Aumento dell'osso alveolare umano: confronto tra la struttura Ti-Mesh 3D CAD-CAM e una struttura Ti-Mesh convenzionale fabbricata al momento dell'intervento chirurgico
This research compares a chairside Titanium Mesh frame fabrication used during bone grafting procedures with the use of a computer-aided design/computer-assisted manufacture (CAD-CAM) Titanium Mesh frame. In addition, a novel method of measuring soft tissue thickness will be tested using an Optical scanner at various times during the sequence of surgeries.
The device used for shaping is a very thin, perforated titanium metal sheet with numerous small perforations (referred to as Micromesh). The construction of this device is usually accomplished chairside at the time of the surgery with custom cutting and shaping done using cues from the geometry of the surgical defect. An alternative approach will be tested where the mesh is pre-designed using digital information provided by a special xray and an optical scan device which takes a digital impression of the tooth and soft tissue surface. A digitally designed frame can then be printed using CAD-CAM software prior to surgery. This should reduce surgical time.
A randomized control trial of 30 patients needing 3-D bone augmentation will be conducted comparing chairside fabrication of Ti-MESH or TEST- CAD-CAM designed and preprinted Ti-MESH to investigate these objectives:
- Compare the operative times required for placement and removal of two different Ti-MESH frame fabrications
- Compare post-op wound healing -Ti MESH exposure rates, bone production (volume, contour, and quality) and soft tissue thickness changes during the 1-year study period.
Panoramica dello studio
Stato
Condizioni
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Massachusetts
-
Boston, Massachusetts, Stati Uniti, 02118
- BU Goldman School of Dental Medicine
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Partially edentulous
- Adult dental patients that require moderate 3-D bone augmentation for dental implant site improvement
Exclusion Criteria:
- Poor oral hygiene indices for microbial plaque (PI) and gingival inflammation (GI)
- Patients who have been on Chemotherapy or Radiation therapy within last 5 years.
- Patients under active treatment with following medications: Bisphosphonates, Gabapentin, Glucocorticoids, Methotrexate, or Estrogen supplements.
- Subjects under the direct supervision of the PI
- Smoking more than 10 cigarettes per day
- Uncontrolled diabetes or other metabolic disorders
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: CAD-CAM Ti-Mesh frame
Participants randomized into this arm will have their tooth loss treated with CAD-CAM designed and preprinted Ti-MESH during surgery. |
CAD-CAM technology which is the process of designing and manufacturing a custom-made dental device, or a patient-specific dental device from an industrialized product, with the aid of a computer.will be used to plan and preprint a 3-D Ti-Mesh frame prior to the surgery. |
|
Comparatore attivo: Conventional Ti-Mesh frame
Participants randomized into this arm will have their tooth loss treated with conventional chairside fabrication of Ti-MESH during surgery. |
A three-dimensional frame or cage of Ti-Mesh or Ti-reinforced d-polytetrafluoroethylene (PTFE) will be fashioned during the surgery to contain, shape and stabilize the bone graft materials (the internal scaffold). This 3-D frame will be custom fabricated from a perforated Ti Mesh sheet material at the time of surgery which takes considerable time and skill. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Bone contour accuracy
Lasso di tempo: 5 months post op
|
Bone contour accuracy will be derived by merger of the post op Cone beam computed tomography (CBCT) DICOM file with the CBCT-1/CEREC-1/Virtual Implant file produced at the planning stage. Accuracy of fit will be calculated for volume and linear measures (4 sides of each implant-MDBL) horizontal and vertical from the implant restorative platform. |
5 months post op
|
|
Total surgical time
Lasso di tempo: 2 hours
|
Total surgical time is defined as from incision time to completion of sutures and will be measured in minutes. |
2 hours
|
|
Surgical exposure time for recipient site
Lasso di tempo: 5 minutes
|
Surgical exposure time will be measured for recipient site in minutes |
5 minutes
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Ti-Mesh exposure incidence
Lasso di tempo: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
Number of exposures |
1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
|
Ti-Mesh exposure size
Lasso di tempo: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
Ti-Mesh exposure size will be measured in millimeters |
1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
|
Ti-Mesh exposure location
Lasso di tempo: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
Ti-Mesh exposure location will be documented within mucosa, gingiva, or at the incision line |
1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
|
Percentage of Vital bone
Lasso di tempo: 6 months
|
Percentage of vital bone will be measured in histologic sections of bone core taken at time of implant surgery. |
6 months
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: Serge Dibart, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics
- Direttore dello studio: Albert M Price, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- H-43856
- AP 37 (Altro identificatore: Geistlich Pharma North America Inc)
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .