Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Confronto tra strutture Ti-Mesh per l'aumento dell'osso alveolare

29 settembre 2026 aggiornato da: Boston University

Aumento dell'osso alveolare umano: confronto tra la struttura Ti-Mesh 3D CAD-CAM e una struttura Ti-Mesh convenzionale fabbricata al momento dell'intervento chirurgico

This research compares a chairside Titanium Mesh frame fabrication used during bone grafting procedures with the use of a computer-aided design/computer-assisted manufacture (CAD-CAM) Titanium Mesh frame. In addition, a novel method of measuring soft tissue thickness will be tested using an Optical scanner at various times during the sequence of surgeries.

The device used for shaping is a very thin, perforated titanium metal sheet with numerous small perforations (referred to as Micromesh). The construction of this device is usually accomplished chairside at the time of the surgery with custom cutting and shaping done using cues from the geometry of the surgical defect. An alternative approach will be tested where the mesh is pre-designed using digital information provided by a special xray and an optical scan device which takes a digital impression of the tooth and soft tissue surface. A digitally designed frame can then be printed using CAD-CAM software prior to surgery. This should reduce surgical time.

A randomized control trial of 30 patients needing 3-D bone augmentation will be conducted comparing chairside fabrication of Ti-MESH or TEST- CAD-CAM designed and preprinted Ti-MESH to investigate these objectives:

  1. Compare the operative times required for placement and removal of two different Ti-MESH frame fabrications
  2. Compare post-op wound healing -Ti MESH exposure rates, bone production (volume, contour, and quality) and soft tissue thickness changes during the 1-year study period.

Panoramica dello studio

Tipo di studio

Interventistico

Iscrizione (Stimato)

30

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Massachusetts
      • Boston, Massachusetts, Stati Uniti, 02118
        • BU Goldman School of Dental Medicine

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 80 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Partially edentulous
  • Adult dental patients that require moderate 3-D bone augmentation for dental implant site improvement

Exclusion Criteria:

  • Poor oral hygiene indices for microbial plaque (PI) and gingival inflammation (GI)
  • Patients who have been on Chemotherapy or Radiation therapy within last 5 years.
  • Patients under active treatment with following medications: Bisphosphonates, Gabapentin, Glucocorticoids, Methotrexate, or Estrogen supplements.
  • Subjects under the direct supervision of the PI
  • Smoking more than 10 cigarettes per day
  • Uncontrolled diabetes or other metabolic disorders

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: CAD-CAM Ti-Mesh frame

Participants randomized into this arm will have their tooth loss treated with CAD-CAM designed and preprinted Ti-MESH during surgery.

CAD-CAM technology which is the process of designing and manufacturing a custom-made dental device, or a patient-specific dental device from an industrialized product, with the aid of a computer.will be used to plan and preprint a 3-D Ti-Mesh frame prior to the surgery.

Comparatore attivo: Conventional Ti-Mesh frame

Participants randomized into this arm will have their tooth loss treated with conventional chairside fabrication of Ti-MESH during surgery.

A three-dimensional frame or cage of Ti-Mesh or Ti-reinforced d-polytetrafluoroethylene (PTFE) will be fashioned during the surgery to contain, shape and stabilize the bone graft materials (the internal scaffold). This 3-D frame will be custom fabricated from a perforated Ti Mesh sheet material at the time of surgery which takes considerable time and skill.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Bone contour accuracy
Lasso di tempo: 5 months post op

Bone contour accuracy will be derived by merger of the post op Cone beam computed tomography (CBCT) DICOM file with the CBCT-1/CEREC-1/Virtual Implant file produced at the planning stage. Accuracy of fit will be calculated for volume and linear measures (4 sides of each implant-MDBL) horizontal and vertical from the implant restorative platform.

5 months post op
Total surgical time
Lasso di tempo: 2 hours

Total surgical time is defined as from incision time to completion of sutures and will be measured in minutes.

2 hours
Surgical exposure time for recipient site
Lasso di tempo: 5 minutes

Surgical exposure time will be measured for recipient site in minutes

5 minutes

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Ti-Mesh exposure incidence
Lasso di tempo: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks

Number of exposures

1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
Ti-Mesh exposure size
Lasso di tempo: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks

Ti-Mesh exposure size will be measured in millimeters

1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
Ti-Mesh exposure location
Lasso di tempo: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks

Ti-Mesh exposure location will be documented within mucosa, gingiva, or at the incision line

1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
Percentage of Vital bone
Lasso di tempo: 6 months

Percentage of vital bone will be measured in histologic sections of bone core taken at time of implant surgery.

6 months

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Serge Dibart, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics
  • Direttore dello studio: Albert M Price, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

25 gennaio 2024

Completamento primario (Stimato)

1 settembre 2027

Completamento dello studio (Stimato)

1 dicembre 2027

Date di iscrizione allo studio

Primo inviato

5 ottobre 2023

Primo inviato che soddisfa i criteri di controllo qualità

5 ottobre 2023

Primo Inserito (Effettivo)

11 ottobre 2023

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

1 ottobre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

29 settembre 2026

Ultimo verificato

1 settembre 2026

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi