- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT06077513
치조골 확대술을 위한 Ti-Mesh 프레임 비교
인간 치조골 확대술: 수술 시 제작된 기존 Ti-Mesh 프레임과 3D CAD-CAM 타임메시 프레임 비교
This research compares a chairside Titanium Mesh frame fabrication used during bone grafting procedures with the use of a computer-aided design/computer-assisted manufacture (CAD-CAM) Titanium Mesh frame. In addition, a novel method of measuring soft tissue thickness will be tested using an Optical scanner at various times during the sequence of surgeries.
The device used for shaping is a very thin, perforated titanium metal sheet with numerous small perforations (referred to as Micromesh). The construction of this device is usually accomplished chairside at the time of the surgery with custom cutting and shaping done using cues from the geometry of the surgical defect. An alternative approach will be tested where the mesh is pre-designed using digital information provided by a special xray and an optical scan device which takes a digital impression of the tooth and soft tissue surface. A digitally designed frame can then be printed using CAD-CAM software prior to surgery. This should reduce surgical time.
A randomized control trial of 30 patients needing 3-D bone augmentation will be conducted comparing chairside fabrication of Ti-MESH or TEST- CAD-CAM designed and preprinted Ti-MESH to investigate these objectives:
- Compare the operative times required for placement and removal of two different Ti-MESH frame fabrications
- Compare post-op wound healing -Ti MESH exposure rates, bone production (volume, contour, and quality) and soft tissue thickness changes during the 1-year study period.
연구 개요
상태
정황
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Massachusetts
-
Boston, Massachusetts, 미국, 02118
- BU Goldman School of Dental Medicine
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Partially edentulous
- Adult dental patients that require moderate 3-D bone augmentation for dental implant site improvement
Exclusion Criteria:
- Poor oral hygiene indices for microbial plaque (PI) and gingival inflammation (GI)
- Patients who have been on Chemotherapy or Radiation therapy within last 5 years.
- Patients under active treatment with following medications: Bisphosphonates, Gabapentin, Glucocorticoids, Methotrexate, or Estrogen supplements.
- Subjects under the direct supervision of the PI
- Smoking more than 10 cigarettes per day
- Uncontrolled diabetes or other metabolic disorders
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: CAD-CAM Ti-Mesh frame
Participants randomized into this arm will have their tooth loss treated with CAD-CAM designed and preprinted Ti-MESH during surgery. |
CAD-CAM technology which is the process of designing and manufacturing a custom-made dental device, or a patient-specific dental device from an industrialized product, with the aid of a computer.will be used to plan and preprint a 3-D Ti-Mesh frame prior to the surgery. |
|
활성 비교기: Conventional Ti-Mesh frame
Participants randomized into this arm will have their tooth loss treated with conventional chairside fabrication of Ti-MESH during surgery. |
A three-dimensional frame or cage of Ti-Mesh or Ti-reinforced d-polytetrafluoroethylene (PTFE) will be fashioned during the surgery to contain, shape and stabilize the bone graft materials (the internal scaffold). This 3-D frame will be custom fabricated from a perforated Ti Mesh sheet material at the time of surgery which takes considerable time and skill. |
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Bone contour accuracy
기간: 5 months post op
|
Bone contour accuracy will be derived by merger of the post op Cone beam computed tomography (CBCT) DICOM file with the CBCT-1/CEREC-1/Virtual Implant file produced at the planning stage. Accuracy of fit will be calculated for volume and linear measures (4 sides of each implant-MDBL) horizontal and vertical from the implant restorative platform. |
5 months post op
|
|
Total surgical time
기간: 2 hours
|
Total surgical time is defined as from incision time to completion of sutures and will be measured in minutes. |
2 hours
|
|
Surgical exposure time for recipient site
기간: 5 minutes
|
Surgical exposure time will be measured for recipient site in minutes |
5 minutes
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Ti-Mesh exposure incidence
기간: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
Number of exposures |
1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
|
Ti-Mesh exposure size
기간: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
Ti-Mesh exposure size will be measured in millimeters |
1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
|
Ti-Mesh exposure location
기간: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
Ti-Mesh exposure location will be documented within mucosa, gingiva, or at the incision line |
1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
|
Percentage of Vital bone
기간: 6 months
|
Percentage of vital bone will be measured in histologic sections of bone core taken at time of implant surgery. |
6 months
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Serge Dibart, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics
- 연구 책임자: Albert M Price, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- H-43856
- AP 37 (기타 식별자: Geistlich Pharma North America Inc)
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .