Vergelijking van Ti-Mesh-frames voor alveolaire botvergroting

29 september 2026 bijgewerkt door: Boston University

Menselijke alveolaire botvergroting: vergelijking van 3D CAD-CAM Ti-mesh-frame met een conventioneel Ti-Mesh-frame vervaardigd ten tijde van de operatie

This research compares a chairside Titanium Mesh frame fabrication used during bone grafting procedures with the use of a computer-aided design/computer-assisted manufacture (CAD-CAM) Titanium Mesh frame. In addition, a novel method of measuring soft tissue thickness will be tested using an Optical scanner at various times during the sequence of surgeries.

The device used for shaping is a very thin, perforated titanium metal sheet with numerous small perforations (referred to as Micromesh). The construction of this device is usually accomplished chairside at the time of the surgery with custom cutting and shaping done using cues from the geometry of the surgical defect. An alternative approach will be tested where the mesh is pre-designed using digital information provided by a special xray and an optical scan device which takes a digital impression of the tooth and soft tissue surface. A digitally designed frame can then be printed using CAD-CAM software prior to surgery. This should reduce surgical time.

A randomized control trial of 30 patients needing 3-D bone augmentation will be conducted comparing chairside fabrication of Ti-MESH or TEST- CAD-CAM designed and preprinted Ti-MESH to investigate these objectives:

  1. Compare the operative times required for placement and removal of two different Ti-MESH frame fabrications
  2. Compare post-op wound healing -Ti MESH exposure rates, bone production (volume, contour, and quality) and soft tissue thickness changes during the 1-year study period.

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Geschat)

30

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Massachusetts
      • Boston, Massachusetts, Verenigde Staten, 02118
        • BU Goldman School of Dental Medicine

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar tot 80 jaar (Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • Partially edentulous
  • Adult dental patients that require moderate 3-D bone augmentation for dental implant site improvement

Exclusion Criteria:

  • Poor oral hygiene indices for microbial plaque (PI) and gingival inflammation (GI)
  • Patients who have been on Chemotherapy or Radiation therapy within last 5 years.
  • Patients under active treatment with following medications: Bisphosphonates, Gabapentin, Glucocorticoids, Methotrexate, or Estrogen supplements.
  • Subjects under the direct supervision of the PI
  • Smoking more than 10 cigarettes per day
  • Uncontrolled diabetes or other metabolic disorders

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: CAD-CAM Ti-Mesh frame

Participants randomized into this arm will have their tooth loss treated with CAD-CAM designed and preprinted Ti-MESH during surgery.

CAD-CAM technology which is the process of designing and manufacturing a custom-made dental device, or a patient-specific dental device from an industrialized product, with the aid of a computer.will be used to plan and preprint a 3-D Ti-Mesh frame prior to the surgery.

Actieve vergelijker: Conventional Ti-Mesh frame

Participants randomized into this arm will have their tooth loss treated with conventional chairside fabrication of Ti-MESH during surgery.

A three-dimensional frame or cage of Ti-Mesh or Ti-reinforced d-polytetrafluoroethylene (PTFE) will be fashioned during the surgery to contain, shape and stabilize the bone graft materials (the internal scaffold). This 3-D frame will be custom fabricated from a perforated Ti Mesh sheet material at the time of surgery which takes considerable time and skill.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Bone contour accuracy
Tijdsspanne: 5 months post op

Bone contour accuracy will be derived by merger of the post op Cone beam computed tomography (CBCT) DICOM file with the CBCT-1/CEREC-1/Virtual Implant file produced at the planning stage. Accuracy of fit will be calculated for volume and linear measures (4 sides of each implant-MDBL) horizontal and vertical from the implant restorative platform.

5 months post op
Total surgical time
Tijdsspanne: 2 hours

Total surgical time is defined as from incision time to completion of sutures and will be measured in minutes.

2 hours
Surgical exposure time for recipient site
Tijdsspanne: 5 minutes

Surgical exposure time will be measured for recipient site in minutes

5 minutes

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Ti-Mesh exposure incidence
Tijdsspanne: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks

Number of exposures

1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
Ti-Mesh exposure size
Tijdsspanne: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks

Ti-Mesh exposure size will be measured in millimeters

1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
Ti-Mesh exposure location
Tijdsspanne: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks

Ti-Mesh exposure location will be documented within mucosa, gingiva, or at the incision line

1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
Percentage of Vital bone
Tijdsspanne: 6 months

Percentage of vital bone will be measured in histologic sections of bone core taken at time of implant surgery.

6 months

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Serge Dibart, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics
  • Studie directeur: Albert M Price, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

25 januari 2024

Primaire voltooiing (Geschat)

1 september 2027

Studie voltooiing (Geschat)

1 december 2027

Studieregistratiedata

Eerst ingediend

5 oktober 2023

Eerst ingediend dat voldeed aan de QC-criteria

5 oktober 2023

Eerst geplaatst (Werkelijk)

11 oktober 2023

Updates van studierecords

Laatste update geplaatst (Werkelijk)

1 oktober 2026

Laatste update ingediend die voldeed aan QC-criteria

29 september 2026

Laatst geverifieerd

1 september 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren