- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT06077513
Comparación del marco Ti-Mesh para el aumento del hueso alveolar
Aumento del hueso alveolar humano: comparación del marco CAD-CAM Ti-mesh tridimensional con un marco Ti-Mesh convencional fabricado en el momento de la cirugía
This research compares a chairside Titanium Mesh frame fabrication used during bone grafting procedures with the use of a computer-aided design/computer-assisted manufacture (CAD-CAM) Titanium Mesh frame. In addition, a novel method of measuring soft tissue thickness will be tested using an Optical scanner at various times during the sequence of surgeries.
The device used for shaping is a very thin, perforated titanium metal sheet with numerous small perforations (referred to as Micromesh). The construction of this device is usually accomplished chairside at the time of the surgery with custom cutting and shaping done using cues from the geometry of the surgical defect. An alternative approach will be tested where the mesh is pre-designed using digital information provided by a special xray and an optical scan device which takes a digital impression of the tooth and soft tissue surface. A digitally designed frame can then be printed using CAD-CAM software prior to surgery. This should reduce surgical time.
A randomized control trial of 30 patients needing 3-D bone augmentation will be conducted comparing chairside fabrication of Ti-MESH or TEST- CAD-CAM designed and preprinted Ti-MESH to investigate these objectives:
- Compare the operative times required for placement and removal of two different Ti-MESH frame fabrications
- Compare post-op wound healing -Ti MESH exposure rates, bone production (volume, contour, and quality) and soft tissue thickness changes during the 1-year study period.
Descripción general del estudio
Estado
Condiciones
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Massachusetts
-
Boston, Massachusetts, Estados Unidos, 02118
- BU Goldman School of Dental Medicine
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Partially edentulous
- Adult dental patients that require moderate 3-D bone augmentation for dental implant site improvement
Exclusion Criteria:
- Poor oral hygiene indices for microbial plaque (PI) and gingival inflammation (GI)
- Patients who have been on Chemotherapy or Radiation therapy within last 5 years.
- Patients under active treatment with following medications: Bisphosphonates, Gabapentin, Glucocorticoids, Methotrexate, or Estrogen supplements.
- Subjects under the direct supervision of the PI
- Smoking more than 10 cigarettes per day
- Uncontrolled diabetes or other metabolic disorders
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: CAD-CAM Ti-Mesh frame
Participants randomized into this arm will have their tooth loss treated with CAD-CAM designed and preprinted Ti-MESH during surgery. |
CAD-CAM technology which is the process of designing and manufacturing a custom-made dental device, or a patient-specific dental device from an industrialized product, with the aid of a computer.will be used to plan and preprint a 3-D Ti-Mesh frame prior to the surgery. |
|
Comparador activo: Conventional Ti-Mesh frame
Participants randomized into this arm will have their tooth loss treated with conventional chairside fabrication of Ti-MESH during surgery. |
A three-dimensional frame or cage of Ti-Mesh or Ti-reinforced d-polytetrafluoroethylene (PTFE) will be fashioned during the surgery to contain, shape and stabilize the bone graft materials (the internal scaffold). This 3-D frame will be custom fabricated from a perforated Ti Mesh sheet material at the time of surgery which takes considerable time and skill. |
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Bone contour accuracy
Periodo de tiempo: 5 months post op
|
Bone contour accuracy will be derived by merger of the post op Cone beam computed tomography (CBCT) DICOM file with the CBCT-1/CEREC-1/Virtual Implant file produced at the planning stage. Accuracy of fit will be calculated for volume and linear measures (4 sides of each implant-MDBL) horizontal and vertical from the implant restorative platform. |
5 months post op
|
|
Total surgical time
Periodo de tiempo: 2 hours
|
Total surgical time is defined as from incision time to completion of sutures and will be measured in minutes. |
2 hours
|
|
Surgical exposure time for recipient site
Periodo de tiempo: 5 minutes
|
Surgical exposure time will be measured for recipient site in minutes |
5 minutes
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Ti-Mesh exposure incidence
Periodo de tiempo: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
Number of exposures |
1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
|
Ti-Mesh exposure size
Periodo de tiempo: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
Ti-Mesh exposure size will be measured in millimeters |
1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
|
Ti-Mesh exposure location
Periodo de tiempo: 1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
Ti-Mesh exposure location will be documented within mucosa, gingiva, or at the incision line |
1 week, 2 weeks, 4weeks, 8 weeks, 12 weeks, 16 weeks, 20 weeks, 24 weeks
|
|
Percentage of Vital bone
Periodo de tiempo: 6 months
|
Percentage of vital bone will be measured in histologic sections of bone core taken at time of implant surgery. |
6 months
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Serge Dibart, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics
- Director de estudio: Albert M Price, DMD, BU Goldman School of Dental Medicine, Oral Biology/Periodontics
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- H-43856
- AP 37 (Otro identificador: Geistlich Pharma North America Inc)
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .