超音波センサーの原理を利用した乳房検査補助ツールの開発
超音波センサーの原理を利用した乳房検査支援ツールの開発:開発・検証研究
The accuracy of breast examinations and ultrasonography performed clinically to detect breast mass varies greatly depending on the physician's skill level, and the accuracy of breast examinations by non-experts is particularly low. In this study, we aimed to validate whether the concurrent use of ultrasound sensor technology is an efficient strategy for the purpose of improving the sensitivity of detecting breast masses through breast examination.
調査の概要
詳細な説明
[Background] This research team would like to conduct this study based on the idea that the sensitivity of breast palpation can be improved by moving away from traditional breast palpation, which is simply performed by hand, and using auxiliary examination equipment based on ultrasonic sensor technology. In particular, our research team focused on the waveform of the ultrasound itself rather than the visual images obtained through the ultrasound device. In the existing breast ultrasound, the medical staff reads images created through ultrasound from multiple sensors to confirm the possibility of breast cancer, and this is read based on the medical staff's very subjective opinions. However, ultrasonic waveforms acquired through ultrasound can store information about the waveform as data and thus be implemented as objective values.
[Study design] Prospective, multi-institutional
[Study protocol]
① Preoperative ultrasound sensor-based diagnostic equipment was applied to 200 patients with breast mass among patients admitted to the breast surgery department, and prospectively obtained ultrasound echo signal data generated by the mass.
② For this purpose, the researcher uses equipment containing a single ultrasound sensor to manually scan the mass lesion area and no evidence disease area.
③ Diagnostic performance (judgment for presence or absence of a tumor) of diagnostic tool based on ultrasound sensor technology through an artificial intelligence algorithm designed based on ultrasound wavelength and frequency optimized for mass detection.
[Objectives]
- Primary endpoint Sensitivity/specificity/predictive value/accuracy/positive & negative predictive of diagnostic performance
- Secondary endpoint Artificial intelligence algorithm efficacy
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
Seoul
-
Seoul、Seoul、韓国、03080
- Seoul National University Hospital
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
scheduled for surgery after a tumor has been confirmed on breast ultrasound examination
説明
Inclusion Criteria:
- female patients between 18 and 80 years of age who are scheduled for surgery after a tumor has been confirmed on breast ultrasound examination
Exclusion Criteria:
- Patients diagnosed with breast cancer after biopsy with non-mass enhancement or calcification
- Inflammatory breast cancer
- Patients whose cancer has invaded the skin and broken through
- Patients with skin diseases
- Women who refused to participate in the study
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:COHORT
- 時間の展望:PROSPECTIVE
コホートと介入
グループ/コホート |
|---|
|
超音波グループ
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Device performance
時間枠:Within 1 year after the study participant registration deadline
|
Sensitivity/specificity/predictive value/accuracy/positive predictive value/ negative predictive value of diagnostic performance |
Within 1 year after the study participant registration deadline
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
人工知能アルゴリズムの有効性
時間枠:研究参加者登録締切後2年以内
|
研究参加者登録締切後2年以内
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- 2209-039-1357
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。