- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT03127683
The Influence of Head and Neck Position on Performance of Ambu AuraGainTM in Children
The influence of different head and neck positions on the effectiveness of ventilation with the Ambu AuraGain airway remains unevaluated.
This study aimed to evaluate the influence of different head and neck positions on ventilation with the AuraGain airway.
An AuraGain will be placed in all patients, and mechanical ventilation will be performed using a volume-controlled mode with a tidal volume of 10 ml/kg.
The expiratory tidal volume, peak inspiratory pressure, oropharyngeal leak pressure, and ventilation score will be assessed first for the neutral head position and then for the extended, flexed, and rotated head positions in a random order.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Seoul, Korea, republiek van, 110-744
- Seoul National University Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Children < 7 years old who scheduled for general anesthesia using supraglottic airway
Exclusion Criteria:
- Children who require tracheal intubation
- Emergency operation without NPO
- History of C-spine surgery or disease
- History of Esophageal disease or surgery
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Ander
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: AuraGain group
An AuraGain will be placed in all patients, and mechanical ventilation will be performed using a volume-controlled mode with a tidal volume of 10 ml/kg. The expiratory tidal volume, peak inspiratory pressure, oropharyngeal leak pressure, and ventilation score will be assessed first for the neutral head position and then for the extended, flexed, and rotated head positions in a random order. |
The expiratory tidal volume, peak inspiratory pressure, oropharyngeal leak pressure, and ventilation score will be assessed at this position
Andere namen:
The expiratory tidal volume, peak inspiratory pressure, oropharyngeal leak pressure, and ventilation score will be assessed at this position
Andere namen:
The expiratory tidal volume, peak inspiratory pressure, oropharyngeal leak pressure, and ventilation score will be assessed at this position
Andere namen:
The expiratory tidal volume, peak inspiratory pressure, oropharyngeal leak pressure, and ventilation score will be assessed at this position
Andere namen:
Single Use Laryngeal Mask Sterile
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Oropharyngeal leak pressure
Tijdsspanne: 30 seconds after positioning of head and neck
|
The airway pressure at which a leak sound is detected around the patient's mouth and at which the airway pressure has reached equilibrium, when the pressure-limiting valve of the anesthesia breathing system is closed and the fresh gas flow rate was fixed at 3 L/min
|
30 seconds after positioning of head and neck
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Peak inspiratory pressure
Tijdsspanne: 30 seconds after positioning of head and neck
|
peak airway pressure
|
30 seconds after positioning of head and neck
|
|
Tidal volume
Tijdsspanne: 30 seconds after positioning of head and neck
|
Expiratory tidal volume
|
30 seconds after positioning of head and neck
|
|
Fiberopic bronchoscopic view
Tijdsspanne: 30 seconds after positioning of head and neck
|
1.
No visible glottis 2. Visible glottis and anterior epiglottis 3. Visible glottis and posterior epiglottis 4.
Only visible glottis
|
30 seconds after positioning of head and neck
|
Medewerkers en onderzoekers
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- H1704-069-844
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .
Klinische onderzoeken op Neutral position
-
Tarsus UniversityNog niet aan het wervenPasgeboren zorgTurkije (Türkiye)
-
University of HoustonVoltooidAngst stoornissenVerenigde Staten
-
Washington University School of MedicineEmpNiaWervingRadiotherapie | Radiotherapie, beeldgestuurdVerenigde Staten
-
University of St.GallenWervingMobiele applicaties | Herinneringssystemen | Naleving van de patiëntZwitserland
-
Karamanoğlu Mehmetbey UniversityVoltooidPijn | Verpleegkundige cariës | Pasgeboren; VitaliteitTurkije (Türkiye)
-
King's College LondonGuy's HospitalVoltooidTemporomandibulaire aandoeningen (TMD)Verenigd Koninkrijk
-
Assistance Publique - Hôpitaux de ParisURC-CIC Paris Descartes Necker CochinVoltooidEpidurale analgesie voor arbeid en bevallingFrankrijk