Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Feasibility of the "Heart-track" Rehabilitative Device Prototype

15 augustus 2019 bijgewerkt door: Eng Chan Neoh, Tan Tock Seng Hospital

Feasibility of the "Heart-track" Rehabilitative Device Prototype Designed for Exercise Training Post Coronary Revascularisation

Abstract Title: "Heart-track" cardiac rehabilitation device prototype designed for exercise training post coronary revascularisation: A usability study Background: Percutaneous Coronary Intervention (PCI) is a common surgical procedure for heart attack patients. International guidelines recommend that all patients complete phase two (outpatient) cardiac rehabilitation (CR) after PCI, as it plays a critical role in reducing five-year cardiovascular mortality and the risk of cardiovascular-related hospital admission. Patients in our institution have suboptimal exercise compliance and effectiveness during cardiac rehabilitation. Root cause analysis identified 'lack of commitment', 'lack of care monitoring and continuity' and 'lack of motivation and engagement' to be key contributing factors. Yet, healthcare resource limitations necessitate innovation for care continuity and patient engagement. "Heart-track", a novel, app-based innovation was created. By 'game-ifying' cardiac rehabilitative exercise training program, "Heart-track" guides and tracks cardiac rehabilitation at home at patient's comfort.

Purpose: To explore experiences of app usability in terms of content, functionality and design of the prototype "Heart-track" app to improve user experience.

Methods: Twelve community-dwelling adults who are also active member of cardiac rehab support group, aged above 50, and undergone coronary revascularisation for acute myocardial infarction at least 1 year before were recruited. Participants were introduced to "Heart-Track" mobile app system and its navigational characteristics with standardised instructions. Each participant then performed a self-directed Cardiac rehabilitation session using the app. Participants rated their experience with the hardware and software components of "Heart Track", and their acceptance of it as a cardiac rehabilitation tool. Descriptive analysis of quantitative responses were analysed using IBM SPSS software version 19.0 (Armonk, NY: IBM Corp).

Studie Overzicht

Toestand

Voltooid

Interventie / Behandeling

Gedetailleerde beschrijving

Abstract Title: "Heart-track" cardiac rehabilitation device prototype designed for exercise training post coronary revascularisation: A usability study Background: Percutaneous Coronary Intervention (PCI) is a common surgical procedure for heart attack patients. International guidelines recommend that all patients complete phase two (outpatient) cardiac rehabilitation (CR) after PCI, as it plays a critical role in reducing five-year cardiovascular mortality and the risk of cardiovascular-related hospital admission. Patients in our institution have suboptimal exercise compliance and effectiveness during cardiac rehabilitation. Root cause analysis identified 'lack of commitment', 'lack of care monitoring and continuity' and 'lack of motivation and engagement' to be key contributing factors. Yet, healthcare resource limitations necessitate innovation for care continuity and patient engagement. "Heart-track", a novel, app-based innovation was created. By 'game-ifying' cardiac rehabilitative exercise training program, "Heart-track" guides and tracks cardiac rehabilitation at home at patient's comfort.

Purpose: To explore experiences of app usability in terms of content, functionality and design of the prototype "Heart-track" app to improve user experience.

Methods: Twelve community-dwelling adults who are also active member of cardiac rehab support group, aged above 50, and undergone coronary revascularisation for acute myocardial infarction at least 1 year before were recruited. Participants were introduced to "Heart-Track" mobile app system and its navigational characteristics with standardised instructions. Each participant then performed a self-directed Cardiac rehabilitation session using the app. Participants rated their experience with the hardware and software components of "Heart Track", and their acceptance of it as a cardiac rehabilitation tool. Descriptive analysis of quantitative responses were analysed using IBM SPSS software version 19.0 (Armonk, NY: IBM Corp).

Studietype

Ingrijpend

Inschrijving (Werkelijk)

12

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Singapore, Singapore
        • Tan Tock Seng Hospital

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

21 jaar tot 65 jaar (Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • Minimum 21 to 65 years of age
  • conversational fluency in English
  • undergone coronary revascularisation for acute myocardial infarction within last 5 years
  • last documented ejection fraction of at least 40%
  • completed a minimum of eight supervised CR sessions
  • exercises at least once a week for a minimum duration of thirty minutes
  • at least 6 months' experience using a smartphone
  • recent experience(at least one months' experience) with any mobile app
  • displaying capacity for self-monitoring and entering data.

Exclusion Criteria:

-Abnormal physiological response during exercise

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Ander
  • Toewijzing: NVT
  • Interventioneel model: Opdracht voor een enkele groep
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Experimental arm
Participants were introduced to "Heart-Track" mobile app system and its navigational characteristics with standardised instructions. Each participant then performed a self-directed Cardiac rehabilitation session using the app.

Description of the device: Wearable heart rate sensors are used in Heart-track, and a receiver on a smartphone app. Real-time wireless heart rate data is sent to paired mobile device with a wireless distance of up to 10m. The sensor is able to monitor a heart rate range of 30 to 240 beats per minute.

Another component of Heart-track is a "Heart-track" mobile app which captures and reflect real-time heart rate from the heart rate sensor. The mobile app also includes warm-up and cool down exercises that are gamified and supported on a smart-phone running on Android or iOS platforms.

The HR sensor will be purchased by our collaborator, Immersive Play Pte Ltd.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Survey
Tijdsspanne: through study completion, an average of 3 months
Participants rated their experience with the hardware and software components of "Heart Track", and their acceptance of it as a cardiac rehabilitation tool. The survey form is a likert-scale ( Strongly agree to strongly disagree) survey that asking subjects about their feedback and satisfaction about the Heart Track hardware and software, and overall experience using Heart Track.
through study completion, an average of 3 months

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Studie directeur: Eng Chuan Neoh, masters, Senior Physiotherapist

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 juli 2018

Primaire voltooiing (Werkelijk)

30 september 2018

Studie voltooiing (Werkelijk)

30 september 2018

Studieregistratiedata

Eerst ingediend

14 augustus 2019

Eerst ingediend dat voldeed aan de QC-criteria

14 augustus 2019

Eerst geplaatst (Werkelijk)

16 augustus 2019

Updates van studierecords

Laatste update geplaatst (Werkelijk)

19 augustus 2019

Laatste update ingediend die voldeed aan QC-criteria

15 augustus 2019

Laatst geverifieerd

1 augustus 2019

Meer informatie

Termen gerelateerd aan deze studie

Trefwoorden

Andere studie-ID-nummers

  • 2018/00307

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

Nee

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Klinische onderzoeken op Cardiale gebeurtenis

Klinische onderzoeken op Heart Track

Abonneren