- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT06744387
Anterolaterale Tigh (ALT) Flaps Oxygenatie Monitoring door NIRS
Monitoring van de weefseloxygenatie van anterolaterale dijkleppen (ALT), met behulp van FORE-SIGHT ELITE nabij-infraroodspectroscopie (NIRS) - een pilotstudie
The goal of this observational study is to conduct postoperative monitoring in patients who have undergone upper or lower limb reconstructive surgery with an anterolateral thigh flap, by employing the gold standard approach: intermittent assessment of clinical parameters (flap's color, temperature, skin turgor and capillary refill time) combined with Doppler techniques, alongside continuous tissue oxygenation measurements obtained using the CASMED FORE-SIGHT ELITE monitor.The main objective of the study is to provide preliminary data on potential cut-off values indicative of flap failure.
Studie Overzicht
Toestand
Conditie
Gedetailleerde beschrijving
Microvascular reconstructive free flap surgery is commonly used practice in contemporary medicine for managing extensive and complex tissue defects. A primary concern associated with this surgical approach is the risk of flap failure during the postoperative phase, usually resulting from vascular compromise in the first 1-3 days after surgery. Minimizing the time interval to revision surgery enhances the likelihood of salvaging the flap. Hence, effective, and vigilant monitoring is crucial in detecting this feared complication. Currently, the gold standard for monitoring entails the assessment of the flap's skin color, temperature, tissue turgor and capillary refill time, usually supplemented by Doppler techniques. This method of monitoring is labor-intensive and reliant on the expertise of the nursing staff, resulting in variability and inconsistencies. There is a definite need for a more objective, real-time monitoring approach, which is attainable through techniques like Near Infrared Spectroscopy (NIRS). NIRS is a non-invasive tool employed in medical settings to assess regional tissue oxygenation through the placement of specific electrodes at the anatomical site of interest. These electrodes emit photons at multiple wavelengths within the near-infrared spectrum (700-1100 nanometer ) into the tissues and subsequently measure the reflected light patterns. Optical properties of biological molecules alter upon oxygen binding, which causes variations in the near-infrared light absorption patterns. Therefore, the absorption pattern is contingent upon the ratio of oxygenated to deoxygenated hemoglobin. Through analysis of these light patterns and the oxygenated-to-deoxygenated hemoglobin ratio, the NIRS monitor calculates and displays a real-time measurement of tissue oxygen saturation (StO2). This number represents the balance between oxygen supply and uptake in the surrounding tissues and offers information on the underlying hemodynamics. With regards to monitoring after reconstructive flap surgery, NIRS currently occupies a limited role and cannot yet replace the established gold standard of clinical assessment and Doppler techniques. This limited use stems primarily from a lack of consensus on the interpretation of the measured values and the question remains which cut-off values or trends should lead to reintervention. Most of the studies did suggest certain cut-off values, nonetheless, a consensus could not be deduced, except for the ViOptix Tissue Oximeter (ViOptix Inc., Fremont, Ca, USA). An StO2 drop rate of more than 20% per hour during more than 30 minutes could be suggestive of vascular crisis when using this device. Overall, authors attributed the discrepancies in published cut-off values to a lack of large randomized clinical trials and to manufacturer-related variations in the devices, such as number of emitted wavelengths, measuring depth and accuracy, analyzing algorithms.
In this pilot study, we aim to conduct postoperative monitoring in patients who have undergone upper or lower limb reconstructive surgery with an anterolateral thigh flap, employing the gold standard approach for flap surgery, combined with Doppler techniques. Alongside continuous tissue oxygenation measurements will be applied using the FORE-SIGHT ELITE tissue oximeter (FORE-SIGHT ELITE, CAS Medical Systems, Branford, CT USA). The measurements by the FORE-SIGHT ELITE however, remain blinded for the patient and the nursing staff. The data are stored in the FORE-SIGHT ELITE device and will be retrieved after the monitoring period of five days by the investigators. The gold standard approach is used to identify cases of flap failure and distinguish them from control subjects. The 'control' group includes patients with successful flap outcomes and reassuring clinical assessments, while the 'case' group consists of patients with abnormal clinical findings and accompanying flap failure.
The anesthetic management during the reconstructive flap surgery will comply with the standard of care. Each patient will be routinely monitored through pulse oximetry, blood pressure measurements and 5-lead electrocardiography. Patients will be put under general anesthesia using sufentanyl or fentanyl combined with a target-controlled infusion (TCI) of propofol. Muscle paralysis will be induced using rocuronium. Depending on the extensiveness of the operation, a second peripheral line and/or an arterial line for invasive blood pressure measurement and arterial blood gas analysis may be placed. Adequate hemodynamic management is crucial in guaranteeing sufficient perfusion of the flap. Inotropes or vasoactive medications may be employed for this purpose. Body temperature will be monitored and normothermia will be maintained. Following preoperative marking of the flap at the anterolateral thigh (donor site) and identification of dominant vascular branches using Doppler ultrasound, the surgical intervention will be performed. At end of surgery the surgeon marks the location of the main vascular anastomosis sites on the flap for postoperative monitoring of Doppler signals. Two sensors, one at the flap site and one at the donor site, will be attached by the surgeon before departure from the operating room to the Post Anesthetic Care Unit (PACU). Depending on the size of the flap, pediatric sensors will be used. After surgery the patient will stay in the PACU for one night. Continuous NIRS tissue oxygenation measurements will commence upon the patient's arrival at the PACU. The first measurement at the PACU will be considered the baseline value. Trained nurses will conduct hourly clinical assessments of skin color, capillary refill, temperature, skin turgor, and Doppler signals for the first 24 hours. In addition, patients will be routinely monitored with pulse oximetry, 3-lead electrocardiography, and blood pressure measurements. Following their stay in the PACU, patients will be transferred to a regular nursing ward, where the clinical assessment of the flap and the patient's vitals signs monitoring will be continued. In the event of an abnormal clinical evaluation, the nurses will promptly notify the surgeon.
Cases of flap failure will be identified by use of the gold standard(skin color, temperature, tissue turgor and capillary refill time measured by Doppler techniques) along with evaluation of clinical assessments of vital signs while NIRS measurements remain blinded. Following the monitoring period of five days, the stored NIRS values and trends in the FORE-SIGHT ELITE device from both groups will undergo analysis and will be compared. The objective is to gain insight into potential cut-off values for detecting vascular compromise.
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
Antwerp
-
Edegem, Antwerp, België, 2650
- Antwerp University Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
scheduled for reconstructive flap surgery on either upper or lower limb using a fasciocutaneous anterolateral thigh flap
Beschrijving
Inclusion Criteria:
- scheduled for reconstructive flap surgery on either upper or lower limb using a fasciocutaneous anterolateral thigh flap
Exclusion Criteria:
- refusal to provide written informed consent.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Observatiemodellen: COHORT
- Tijdsperspectieven: PROSPECTIVE
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
patiënten met een reconstructieve flapoperatie aan de bovenste of onderste ledematen met behulp van een fasciocutane dijbeenflap
|
Flap failure will be identified, based upon gold standard monitoring (flaps skin color, temperature, tissue turgor and capillary refill time) along with Doppler technique during a postoperative period of five days. In all patients Near Infrared Spectroscopy (NIRS) by FORE-SIGHT ELITE will be applied to obtain continuous tissue oxygenation measurements. NIRS values and trends from patients with flap failure (case group) will be compared to NIRS values and trends from patients with no flap failure(control group). |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
provide preliminary data on potential cut-off values for tissue oxygenation indicative for flap failure
Tijdsspanne: from end of surgery untill five days after surgery
|
a decrease of x percent in tissue oxygenation below the baseline value (first measurement upon arrival at the PACU) of the anterolateral thigh flap. |
from end of surgery untill five days after surgery
|
|
provide preliminary data on potential cut-off values for tissue oxygenation indicative for flap failure
Tijdsspanne: from end of surgery untill five days after surgery
|
a decrease of x percent in tissue oxygenation in the anterolateral thigh flap compared to the reference measurements obtained from the unaffected remaining anterolateral thigh. |
from end of surgery untill five days after surgery
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
retrospective time-to-event analysis in patients with flap failure
Tijdsspanne: through study completion, an average of 1 year
|
a retrospective time-to-event analysis for the index test (NIRS measurements) and the reference test (the gold standard) within the subgroup of cases with flap failure. |
through study completion, an average of 1 year
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- EDGE 003917
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .