- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07435389
VENTILATIE TIJDENS RUIMTEVAART (FASE 2) (VESPA-2)
Space flights expose astronauts to medical risks, particularly respiratory risks, which are exacerbated in microgravity. Devices such as standard oxygen therapy and non-invasive ventilation (NIV) are used, but their performance in microgravity remains poorly studied. Parabolic flights allow these technologies to be evaluated in conditions similar to those encountered during space missions. In an initial study conducted in microgravity during a parabolic flight campaign, the T1 ventilator proved superior to the other devices tested on the test bench. However, its performance in healthy volunteers has not yet been evaluated. The central hypothesis of this exploratory study on healthy volunteers is that non-invasive ventilation, particularly with the CaStar UP helmet (Intersurgical), could offer superior performance to the standard oxygen mask in microgravity, thanks to better leak reduction (data from preclinical work on a test bench).
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
- Naam: Andreia CARVALHO DE FREITAS
- Telefoonnummer: 0033387553323
- E-mail: projet-recherche-clinique@chr-metz-thionville.fr
Studie Locaties
-
-
-
Metz, Frankrijk
- CHR Metz-Thionville
-
Contact:
- Benjamin PEQUIGNOT
- Telefoonnummer: 00 33 87 55 31 30
- E-mail: benjamin.pequignot@chr-metz-thionville.fr
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Healthy volunteers (male or female)
- Aged 18 to 65
- Affiliated with a Social Security scheme and, for non-French residents, holders of a European Health Insurance Card (EHIC) or a Global Health Insurance Card (GHIC)
- Agreeing to participate in the study
- Agreeing to participate in the study
- Having given their informed consent in writing
- Who have undergone a medical examination similar to a standard aeronautical medical examination for private pilot fitness
Exclusion Criteria:
- Individuals who have participated in a previous biomedical research protocol
- whose exclusion period has not ended.
- Individuals in a subordinate relationship with the principal investigator or scientific director.
- Pregnant or breastfeeding women (urine pregnancy test for women of childbearing age).
- Protected adults (under guardianship, curatorship, or judicial protection)
- Flu-like symptoms, digestive symptoms (nausea, vomiting), fever.
- Altered mental state (flight-related anxiety, phobic state).
- Failure to attend the Novespace safety briefing.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Ander
- Toewijzing: Gerandomiseerd
- Interventioneel model: Crossover-opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: ABC
A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical) C. Standard oxygen therapy without EcoLite gas mask |
A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). C. Standard oxygen therapy without EcoLite gas mask (Intersurgical) |
|
Experimenteel: ACB
A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask C. Standard oxygen therapy without EcoLite gas mask B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical) |
A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). C. Standard oxygen therapy without EcoLite gas mask (Intersurgical) |
|
Experimenteel: BAC
B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical) A . Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask C. Standard oxygen therapy without EcoLite gas mask |
A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). C. Standard oxygen therapy without EcoLite gas mask (Intersurgical) |
|
Experimenteel: BCA
B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical) C. Standard oxygen therapy without EcoLite gas mask A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask |
A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). C. Standard oxygen therapy without EcoLite gas mask (Intersurgical) |
|
Experimenteel: CAB
C. Standard oxygen therapy without EcoLite gas mask A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical) |
A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). C. Standard oxygen therapy without EcoLite gas mask (Intersurgical) |
|
Experimenteel: CBA
C. Standard oxygen therapy without EcoLite gas mask B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical) A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask |
A. Non-invasive ventilation with T1 ventilator (Hamilton) and BiTrac mask (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). B. Non-invasive ventilation with T1 ventilator (Hamilton) and CaStar UP helmet (Intersurgical): specific settings (AI 10 cmH2O, PEEP 5 cmH2O, FiO2 21%, etc.). C. Standard oxygen therapy without EcoLite gas mask (Intersurgical) |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Expiratoir tidale volume
Tijdsspanne: 24 uur
|
24 uur
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
1. Average difference between the inspiratory assistance/PEP and the pressure
Tijdsspanne: 24 hours
|
Measured by the pneumotachograph during the last 5 respiratory cycles of the 22-second weightlessness phase |
24 hours
|
|
2. Number of double triggers and intra-cycle efforts
Tijdsspanne: 24 hours
|
during the last 5 respiratory cycles of the 22-second weightlessness phase, as observed when reading the curves on the pneumotachograph |
24 hours
|
|
3. Average change in the "Lung volume" parameter, measured noninvasively by thoracic electrical impedance tomography (EIT)
Tijdsspanne: 24 hours
|
During the last 5 respiratory cycles of the 22-second weightlessness phase |
24 hours
|
|
4. Self-assessment scale for dyspnea on a scale of 1 to 10
Tijdsspanne: 24 hours
|
To be evaluated at the end of the 22-second run (Numeric Rating Scale (NRS)) 0 = no dyspnea 10 = maximum imaginable dyspnea |
24 hours
|
|
5. CO₂-inspired tidal volume and average transcutaneous CO₂ saturation (PETCO₂)
Tijdsspanne: 24 hours
|
over the last 5 respiratory cycles during the 22-second weightlessness phase, as measured by a capnostat and by transcutaneous CO₂ measurement |
24 hours
|
|
6. Occurrence of an adverse event: PETCO2 > 50 mmHg
Tijdsspanne: 48 hours
|
dyspnea score > 8/10, or nausea (yes/no on questioning) |
48 hours
|
|
7.The average respiratory
Tijdsspanne: 24 hours
|
Rate over the last 5 respiratory cycles during the 22-second weightless phase. |
24 hours
|
Medewerkers en onderzoekers
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- 2025-03-CHRMT
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .