- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT06058650
Orientação sobre imagens moleculares da mama para biópsia mamária para pacientes com anomalias mamárias
Estudo clínico piloto para avaliar imagens moleculares da mama - orientação para amostragem de anormalidades mamárias
This clinical trial tests how well molecular breast imaging (MBI) works to guide the collection of a breast biopsy in patients with a breast abnormality. Currently, a biopsy is often guided by either ultrasound or mammography in order to ensure that a sample of the correct part of the breast is taken. Sometimes a lesion or part of the lesion cannot be seen on ultrasound or mammography, and, therefore, a biopsy guided with ultrasound or mammography may not be always be accurate. Studies have shown that high resolution MBI may have potential to improve the detection of some breast tumors. This trial uses a new high-resolution MBI system that may help perform a biopsy using MBI.
Visão geral do estudo
Status
Condições
Descrição detalhada
PRIMARY OBJECTIVE:
I. To evaluate a methodology for MBI-guided biopsy of suspicious breast lesions.
OUTLINE: Patients are assigned to 1 of 2 study parts.
PART I: Patients receive technetium Tc-99m sestamibi intravenously (IV) and undergo MBI on study.
PART II: Patients receive technetium Tc-99m sestamibi IV and undergo MBI. Patients whose breast lesions of interest are visualized on MBI then undergo breast biopsy using the Stereo Navigator accessory.
After completion of study intervention, patients may be asked to follow up at 3-6 months.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
- Nome: Clinical Trials Referral Office
- Número de telefone: 855-776-0015
- E-mail: mayocliniccancerstudies@mayo.edu
Locais de estudo
-
-
Minnesota
-
Rochester, Minnesota, Estados Unidos, 55905
- Recrutamento
- Mayo Clinic in Rochester
-
Contato:
- Clinical Trials Referral Office
- Número de telefone: 855-776-0015
- E-mail: mayocliniccancerstudies@mayo.edu
-
Investigador principal:
- Katie N. Hunt, M.D.
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
-
PART I: Women aged 18 years or older
-
PART I: If able to become pregnant, negative pregnancy test within 48 hours prior to MBI biopsy procedure
-
PART I: Individuals who have previously (within the last 3 years) undergo an MBI study and were found to have at least one breast imaging finding on MBI that was subsequently shown (through additional imaging, biopsy or follow-up) to be benign in nature
-
PART I: Individuals who have agreed to participate in the study and who have signed the study-specific informed consent
-
PART II: Women aged 18 years or older
-
PART II: If able to become pregnant, negative pregnancy test within 48 hours prior to MBI biopsy procedure
-
PART II: Individuals who have previously (within the last 3 years) undergone an MBI study and were found to have at least one breast imaging finding on MBI that was subsequently shown (through additional imaging, biopsy or follow-up) to be benign or probably benign in nature
-
PART II: Individuals who had recent conventional imaging work-up including either x-ray mammography, ultrasound, MBI, or MRI of the breast and are found to have at least one breast imaging finding for which biopsy is required or recommended, specifically:
- Individuals who have a breast abnormality(ies) on imaging with mammography, ultrasound, MBI, or MRI (as per American College of Radiology [ACR] Breast Imaging Reporting and Data System [BIRADS] 3, or higher) and requiring imaging follow-up or biopsy confirmation
-
PART II: Individuals who have agreed to participate in the study and who have signed study-specific informed consent
Exclusion Criteria:
- PART I: Women who are pregnant
- PART I: Women who are currently lactating or discontinued breastfeeding < 2 months prior to the study
- PART I: Age less than 18 years
- PART I: Women with breast implant(s) in the breast containing the lesion of interest
- PART I: Inability to provide informed consent
- PART II: Women who are pregnant
- PART II: Women who are currently lactating or discontinued breastfeeding < 2 months prior to the study
- PART II: Age less than 18 years
- PART II: Women with breast implant(s) in the breast containing the lesion of interest
- PART II: Women who have recently (within the last 3 months) undergone biopsy of the breast finding
- PART II: Women who are scheduled for a sentinel node procedure using radioactive Tc-99m within 24 hours of MBI-guided biopsy
- PART II: Patients with contraindications for core biopsy and other invasive procedures such as blood coagulation disorders, infection, or who are unwilling to discontinue use of anticoagulant medication prior to the procedure
- PART II: Inability to provide informed consent
- PART II: Women who have had surgery on the study breast(s) within the past 12 months
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Diagnóstico
- Alocação: Não randomizado
- Modelo Intervencional: Atribuição sequencial
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Part I (technetium Tc-99m sestamibi, MBI)
Patients receive technetium Tc-99m sestamibi IV and undergo MBI on study. |
Undergo MBI
Outros nomes:
Given IV
Outros nomes:
|
|
Experimental: Part II (technetium Tc-99m sestamibi, MBI, biopsy)
Patients receive technetium Tc-99m sestamibi IV and undergo MBI. Patients whose breast lesions of interest are visualized on MBI then undergo breast biopsy using the Stereo Navigator accessory. |
Undergo MBI
Outros nomes:
Given IV
Outros nomes:
Undergo biopsy of breast
Outros nomes:
Utilization of the Stereo Navigator accessory |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Validation of timeframe
Prazo: Baseline
|
Time from injection of the technetium Tc-99m sestamibi to identification of the appropriate needle guide hole will be reviewed to determine if and where any improvements in workflow can be made to reduce the overall procedure time for patients. |
Baseline
|
|
Change in image of lesion
Prazo: Baseline; Up to 6 months
|
The coordinates of the lesion of interest on the high resolution MBI image will be recorded. The guidance procedure will be considered successful if 1) the pre and post images of the lesion demonstrated one of the following: decreased in size, central or eccentric defect where sampled, or decrease in intensity, or 2) pathology results demonstrate malignancy or a specific benign concordant result. |
Baseline; Up to 6 months
|
|
Accuracy of depth estimation by difference in attenuation from opposing views
Prazo: Baseline; Up to 6 months
|
For each patient in whom pathology confirms successful sampling of the lesion seen on high-resolution molecular breast imaging (MBI), the error in depth estimation will be calculated as the average error for each depth estimation method from all core biopsy samples. This will allow comparison of the accuracy of the 3 different depth estimation methods and potentially provide further information on the strengths and weakness of each of the three methods for depth estimation. Uniformity activity along the entire 20 mm core would indicate failure to biopsy the lesion. Any portion of increased uptake will be noted and the center of activity will be determined relative to the mid-point of the core sample. This distance will be recorded as the difference between estimated depth and true depth. |
Baseline; Up to 6 months
|
|
Accuracy of depth estimation by difference in apparent lesion size
Prazo: Baseline; Up to 6 months
|
For each patient in whom pathology confirms successful sampling of the lesion seen on MBI, the error in depth estimation will be calculated as the average error for each depth estimation method from all core biopsy samples. This will allow comparison of the accuracy of the 3 different depth estimation methods and potentially provide further information on the strengths and weakness of each of the three methods for depth estimation. Uniformity activity along the entire 20 mm core would indicate failure to biopsy the lesion. Any portion of increased uptake will be noted and the center of activity will be determined relative to the mid-point of the core sample. This distance will be recorded as the difference between estimated depth and true depth. |
Baseline; Up to 6 months
|
|
Accuracy of depth estimation by triangulation
Prazo: Baseline; Up to 6 months
|
For each patient in whom pathology confirms successful sampling of the lesion seen on MBI, the error in depth estimation will be calculated as the average error for each depth estimation method from all core biopsy samples. This will allow comparison of the accuracy of the 3 different depth estimation methods and potentially provide further information on the strengths and weakness of each of the three methods for depth estimation. Uniformity activity along the entire 20 mm core would indicate failure to biopsy the lesion. Any portion of increased uptake will be noted and the center of activity will be determined relative to the mid-point of the core sample. This distance will be recorded as the difference between estimated depth and true depth. |
Baseline; Up to 6 months
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Katie N. Hunt, M.D., Mayo Clinic in Rochester
Publicações e links úteis
Links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 18-011329
- 18-011329 (Outro identificador: Mayo Clinic in Rochester)
- NCI-2023-06047 (Identificador de registro: CTRP (Clinical Trial Reporting Program))
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .