- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT06321848
Avvänjningsventilator med ultraljud av hjärta, lunga och diafragma
Det prediktiva värdet av hjärt-, lung- och diafragma-ultraljud för Ventilatoravvänjningsresultat för kirurgiska intensivvårdspatienter
Postextubation distress is detrimental to the prognosis of critically ill patients with successful spontaneous breathing trial. Failure to wean is known to be connected with heart, lung, and diaphragm problems. The aim of this study was to investigate how a composite model comprising diaphragm, lung, and heart ultrasonography indications could predict the weaning outcome.
Methods: Ultrasonic features of the diaphragm, heart, and lungs are going to be collected along with clinical data about the patients. Either the successful weaning group or the failed weaning group is going to comprised the patients. Multivariate logistic regression analysis is going to be used to identify the variables that may be associated with the likelihood of weaning failure. A multiindicator combination model is going to be developed to increase the predictive accuracy after the possible indicators' accuracy in foretelling the weaning outcome was assessed.
Studieöversikt
Status
Betingelser
Detaljerad beskrivning
- Research participants: From March 2024 to March 2026 in the Department of Anesthesia, critical care and pain medicine, Hanoi Medical University Hospital, patients ages over 18 years who will have mechanically ventilated for over 48 h will be recruited. Patients will be excluded if they had a diagnosis of progressive neuromuscular diseases, a history of cardiovascular or respiratory disease who depend on a ventilator at home (COPD, severe bronchial asthma), patients with thoracic surgery and mitral valve surgery. All patients and their families signed informed consents.
- Clinical data collection: Clinical data including gender, age, body mass index, primary disease, length of stay in ICU, duration of mechanical ventilation, acute physiology and chronic health evaluation II, Charlson Comorbidity Index, history of surgery/internal diseases will be collected.
- Spontaneous breathing trial (SBT): Patients will be undergone a 60-min SBT when they meet all the readiness weaning criteria with PS 7cmH2O, PEEP 5cmH2O, FiO2 40%. The vital signs, rapid shallow breathing index (RSBI), NIF, P0.1, tidal volume, respiratory rate, arterial blood gases will be recorded at the beginning and at the end of SBT.
GE Logiq P7 (GE Healthcare, USA) and Philips Affiniti 70G (Philips Ultrasound, USA) ultrasound diagnostic instruments will be used in this study. The heart, lung and diagphragm ultrasonic findings will be recorded by the sonographer well trained in point-of-care ultrasound at the begining and at the end of the SBT.
Tracheal extubation is carried out if the patient does not exhibit symptoms of intolerance, indicating that the SBT treatment was successful. In case intolerance symptoms manifest, return to the initially chosen breathing mode (SIMV, A/C) and record the SBT failure.
- Extubation: After successful SBT: proceed with extubation. The patient is given an oxygen mask at 5L/minute. If the patient does not show intolerance symptoms within 48 hours, the extubation is considered successful. If the patient develops one of the intolerance symptoms during this time period, the extubation failure will be recorded and the patients will be reintubated. Record the values of vital signs and arterial blood gas variables every 24, 48 hours after extubation.
Studietyp
Inskrivning (Faktisk)
Kontakter och platser
Studieorter
-
-
-
Hanoi, Vietnam, 100000
- Hanoi Medical University Hospital
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Testmetod
Studera befolkning
All patients with a duration of mechanical ventilation through an endotracheal tube of more than 48 hours and meeting the criteria of readiness to wean off mechanical ventilation will be included in the study.
Beskrivning
Inclusion Criteria:
- Age >= 18
- The duration of postoperative mechanical ventilation >= 48 hours
Exclusion Criteria:
- Patient had a diagnosis of progressive neuromuscular diseases
- Patient had a history of cardiovascular or respiratory disease who depend on a ventilator at home (COPD, severe bronchial asthma)
- Patients had thoracic surgery or mitral valve surgery.
Studieplan
Hur är studien utformad?
Designdetaljer
- Observationsmodeller: ECOLOGIC_OR_COMMUNITY
- Tidsperspektiv: CROSS_SECTIONAL
Kohorter och interventioner
Grupp / Kohort |
|---|
|
The ventilator weaning patients
Patients who have been on mechanical breathing for longer than 48 hours using an endotracheal tube and who fit the requirements to be weaned off of it |
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
The ventilator weaning outcome
Tidsram: after 48 hours of extubation
|
The outcome of weaning ventilation process (successful or failure) |
after 48 hours of extubation
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
The hospital length of stay
Tidsram: Approximately 5-15 days postextubation
|
The time between hospital admission and discharge |
Approximately 5-15 days postextubation
|
|
The ICU length of stay
Tidsram: Approximately 2-15 days postextubation
|
The time between ICU admission and discharge |
Approximately 2-15 days postextubation
|
|
The duration of mechanical ventilation
Tidsram: Daily assessment of requirement of mechanical ventilation from the time of intubation until the date of weaning mechanical ventilation, up to 12 months
|
The time from the start of mechanical ventilation to extubation |
Daily assessment of requirement of mechanical ventilation from the time of intubation until the date of weaning mechanical ventilation, up to 12 months
|
Samarbetspartners och utredare
Sponsor
Utredare
- Studierektor: Tu Nguyen, Professor, Hanoi Medical University
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Andra studie-ID-nummer
- DUCGM2426
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
IPD-planbeskrivning
The investigators agree that all results and conclusion of this research will be used fully for other researchers
Tidsram för IPD-delning
from March 2026 to the unidentified time
Kriterier för IPD Sharing Access
anesthesiologists all over the world
IPD-delning som stöder informationstyp
- STUDY_PROTOCOL
- ICF
- CSR
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .