Safety and Efficacy of Using MASTER to Perform Endoscopic Submucosal Dissection in Human
Safety and Efficacy of Using MASTER, a Novel Robotics Enhanced Endosurgical System to Perform Endoscopic Submucosal Dissection in Human
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Khek Yu Ho, MBBS; MD
- Phone Number: 65-67726439
- Email: mdchoky@nus.edu.sg
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- patient diagnosed with early gastric or colon cancer, is deemed suitable to undergo endoscopic submucosal dissection and is able/willing to give informed consent.
Exclusion Criteria:
- case is deemed not suitable for endoscopic submucosal dissection
- is on warfarin or other blood thinning agents and those with bleeding disorders
- has uncorrected coagulopathy or severe thrombocytopenia precluding biopsy
- has serious co-morbidities such as heart disease, renal impairment and cancer
- has recently underwent surgery or has a personal history of stomach/colon cancer or surgery
- is unable/unwilling to give informed consent
- is pregnant or breast-feeding women patients who cannot undergo gastroscopies
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: ESD using the MASTER device
Endoscopic submucosal dissection of gastric/colon cancer using the device, MASTER
|
Performing endoscopic submucosal dissection (ESD)of the gastric/colon cancer using the device, MASTER
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Total time taken to complete the ESD procedure
Time Frame: Participants will be followed for the duration of the operation, an expected average of 3 hours
|
The total time spent from docking of MASTER to end of submucosal dissection
|
Participants will be followed for the duration of the operation, an expected average of 3 hours
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Measure of ease of performing the ESD procedure
Time Frame: Participants will be followed for the duration of the operation, an expected average of 3 hours
|
Measure ease of grasping, retraction, and triangulation of robotics end-effectors during the ESD procedure.
Measures are rated as "excellent, good, or poor".
|
Participants will be followed for the duration of the operation, an expected average of 3 hours
|
|
Safety
Time Frame: From start of operation of the ESD procedure, assessed up to 7 days after the procedure
|
Any procedure-related complications that occurs from start ofthe ESD procedure up to 7 days after the procedure.
|
From start of operation of the ESD procedure, assessed up to 7 days after the procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Khek Yu Ho, MBBS; MD, National University Hospital, Singapore
Publications and helpful links
General Publications
- Phee SJ, Sun Z, Wang Z, Wong JY, Ho KY. The future of transluminal surgery. Expert Rev Med Devices. 2011 Nov;8(6):669-71. doi: 10.1586/erd.11.54. No abstract available.
- Sun Z, Ang RY, Lim EW, Wang Z, Ho KY, Phee SJ. Enhancement of a master-slave robotic system for natural orifice transluminal endoscopic surgery. Ann Acad Med Singap. 2011 May;40(5):223-30.
- Ho KY, Phee SJ, Shabbir A, Low SC, Huynh VA, Kencana AP, Yang K, Lomanto D, So BY, Wong YY, Chung SC. Endoscopic submucosal dissection of gastric lesions by using a Master and Slave Transluminal Endoscopic Robot (MASTER). Gastrointest Endosc. 2010 Sep;72(3):593-9. doi: 10.1016/j.gie.2010.04.009. Epub 2010 Jun 19.
- Phee SJ, Low SC, Huynh VA, Kencana AP, Sun ZL, Yang K. Master and slave transluminal endoscopic robot (MASTER) for natural orifice transluminal endoscopic surgery (NOTES). Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:1192-5. doi: 10.1109/IEMBS.2009.5333413.
- Phee SJ, Low SC, Sun ZL, Ho KY, Huang WM, Thant ZM. Robotic system for no-scar gastrointestinal surgery. Int J Med Robot. 2008 Mar;4(1):15-22. doi: 10.1002/rcs.179.
- Phee SJ, Ho KY, Lomanto D, Low SC, Huynh VA, Kencana AP, Yang K, Sun ZL, Chung SC. Natural orifice transgastric endoscopic wedge hepatic resection in an experimental model using an intuitively controlled master and slave transluminal endoscopic robot (MASTER). Surg Endosc. 2010 Sep;24(9):2293-8. doi: 10.1007/s00464-010-0955-8. Epub 2010 Feb 23.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- E11/058
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.