Evaluation of Sound Processor for a Transcutaneous System
Single Center Evaluation of a Sound Processor for a Transcutaneous System
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Gothenburg, Sweden, 413 46
- ENT departement, Sahlgrenska University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Subjects implanted with the Bridging Bone Conductor (BBC) implant
- Subjects that have completed one year follow up in Osseofon BCI (Bone Conduction Implant) study
- Subjects available for 6 months study procedures without affecting the follow ups in the Osseofon BCI study
- Active user of the BCI SP
Exclusion Criteria:
- Inability to participate in follow-ups
- Unsuitable as judged by the principle investigator or the sub-investigator
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Device Feasibility
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Fusion sound processor
The sound processor picks up the sound and transfer it to the implant that convert the sound to vibrations that are transmitted to the inner ear.
|
Sound Processor
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Aided Thresholds Fusion-unaided PTA
Time Frame: 6 months
|
Difference between Fusion-aided and unaided sound field Pure Tone Average of thresholds of frequencies 500, 1000, 2000 and 4000 Hz (PTA 4)
|
6 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Aided Thresholds Fusion-unaided
Time Frame: 6 months
|
Difference between Fusion-aided and unaided sound field Pure Tone thresholds at frequencies 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000 and 8000 Hz
|
6 months
|
|
Aided Thresholds Fusion
Time Frame: Baseline, 1 and 6 month(s)
|
Difference between Fusion-aided sound field pure tones at frequencies 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000 and 8000 Hz at
|
Baseline, 1 and 6 month(s)
|
|
Aided Thresholds Fusion-BCI PTA4
Time Frame: 6 months
|
Difference between Fusion-aided and BCI-aided sound field Pure Tone Average 4 at frequencies 500, 1000, 2000 and 4000 Hz (PTA4)
|
6 months
|
|
Aided Thresholds Fusion-BCI
Time Frame: 6 months
|
Difference between Fusion-aided and BCI-aided sound field pure tones at frequencies 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000 and 8000 Hz
|
6 months
|
|
Magnet Strength
Time Frame: Baseline, 1 and 6 month(s)
|
Difference in magnet strength measured on the patient's heads in Newton
|
Baseline, 1 and 6 month(s)
|
|
Aided Thresholds Fusion PTA4
Time Frame: Baseline, 1 and 6 month(s)
|
Difference between Fusion-aided sound field PTA4, the average for frequencies 500, 1000, 2000 and 4000 Hz (PTA 4)
|
Baseline, 1 and 6 month(s)
|
|
Speech Intelligibility Fusion-unaided %
Time Frame: 6 months
|
Difference between Fusion-aided and unaided speech intelligibility scores (in % correct).
Score indicates number of word repeated correctly with aided with the Fusion sound processor compared to unaided.
Ranges from 0-100, a higher score indicates better performance.
No scale is used.
|
6 months
|
|
Speech Intelligibility Fusion-unaided Signal to Noise Ratio (SNR)
Time Frame: 6 months
|
Difference between Fusion-aided and unaided sound field speech intelligibility scores in SNR.
Score indicates the signal to noise ratio where the subject can repeat 50% of the words correct.
A lower score means a better outcome.
No scale is used.
|
6 months
|
|
Speech Intelligibility Fusion %
Time Frame: Baseline, 1 and 6 month(s)
|
Difference between Fusion-aided speech intelligibility scores (in % correct).
Score indicates number of word repeated correctly with aided with the Fusion sound processor compared to unaided.
Ranges from 0-100, a higher score indicates better performance.
No scale is used.
|
Baseline, 1 and 6 month(s)
|
|
Speech Intelligibility Fusion SNR
Time Frame: Baseline, 1 and 6 month(s)
|
Difference between Fusion-aided sound field sound field speech intelligibility scores in SNR.
Score indicates the signal to noise ratio where the subject can repeat 50% of the words correct.
A lower score means a better outcome.
No scale is used.
|
Baseline, 1 and 6 month(s)
|
|
Speech Intelligibility Fusion-BCI %
Time Frame: 6 months
|
Difference between Fusion-aided BCI-aided speech intelligibility scores (in % correct).
Score indicates number of word repeated correctly with aided with the Fusion sound processor compared to unaided.
Ranges from 0-100, a higher score indicates better performance.
No scale is used
|
6 months
|
|
Speech Intelligibility Fusion-BCI SNR
Time Frame: 6 months
|
Difference between Fusion-aided and BCI-aided sound field speech intelligibility scores in SNR.
Score indicates the signal to noise ratio where the subject can repeat 50% of the words correct.
A lower score means a better outcome.
No scale is used.
|
6 months
|
|
IPS (Inflammation, Pain, Skin Height/Numbness) Evaluation
Time Frame: Baseline, 1 and 6 month(s)
|
Combined score of IInflammation, Pain and Skin height/numbness scale evaluating the skin area under the sound processor.
I scale ranging from 0-4, Pain scale ranging from 0-2, Skin height/numbness ranging from 0-2.
Total score 0-8 (0 no adverse skin condition, 8 maximum adverse skin reactions on all subscales).
Lower score means better performance
|
Baseline, 1 and 6 month(s)
|
|
Subjective Evaluation
Time Frame: Baseline, 1 and 6 month(s)
|
User satisfaction and usability as measured with questionniare "Usage of sound processor" consisting of rating scales on satisfaction of the sound processor.
The scale used is a scale with descriptive values.
|
Baseline, 1 and 6 month(s)
|
|
Subjective Evaluation SSQ
Time Frame: Baseline, 1 and 6 month(s)
|
Subjective performance as measured by Speech, Spatial and Qualities of hearing (SSQ) a scale from 0-10 where 0 represents "Not at all" and 10 represents "Perfect".
A higher score means better performance.
|
Baseline, 1 and 6 month(s)
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Måns Eeg Olofsson, MD, Sahlgrenska University Hospital
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- C58
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.