Hemodynamic Optimization During Single Kidney Transplantation With MostcareUP
There are currently no clear recommendations on hemodynamic targets during kidney transplantation and most anesthesiologists rely on empiric or obsolete parameters such as CVP.
The aim of this study is to investigate hemodynamic management of these patients applying a new generation of advanced monitoring systems such as MOSTCAREUP which can potentially provide a clear overview of the circulatory status beat by beat and to adjust fluid therapy in every single patient or clinical condition.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Renal transplantation is actually considered the optimal elective treatment for end stage kidney disease.
Successful renal transplantation involves the optimization of several parameters. Previous studies have suggested that perioperative hemodynamic factors influence immediate and long-term graft survival.
Perioperative hemodynamic management of this kind of surgery is nowadays focused on optimization of fluid therapy concerning both the donor and the graft and their interaction. Postoperative graft function is not exclusively determined by donor and graft characteristics. Several studies over the last 30 years indeed demonstrated that hemodynamic status of the recipient during kidney transplant surgery relates to graft function and proper management of balancing fluid plays a critical role through maintaining optimal blood volume and so assure an adequate supply of oxygen to the tissues.
Aggressive expansion of the intravascular volume during transplantation surgery has been recommended by most previous studies supporting the so called "liberal" approach to fluid management suggesting that a massive intravascular volume expansion was necessary improve renal blood flow and minimize hypoperfusion caused tissue damages. Nowadays it is clear that adequate early graft function requires perfusion of the transplanted kidney, which may be enhanced by expansion of the intravascular volume in the recipient. However, some studies have reported that aggressive intraoperative volume expansion is not always warranted in kidney transplantation and can expose patients with preexistent cardiac disease or poor myocardial function to the risk of fluid overload, acute respiratory failure, and prolonged ventilation. Moreover fluid overload has been demonstrated to be harmful even for graft perfusion, microcirculation and tissue oxygen delivery.
There are currently no clear recommendations on hemodynamic targets during kidney transplantation and most anesthesiologists rely on empiric or obsolete parameters such as CVP.
The aim of this study is to investigate hemodynamic management of these patients applying a new generation of advanced monitoring systems such as MOSTCAREUP which can potentially provide a clear overview of the circulatory status beat by beat and to adjust fluid therapy in every single patient or clinical condition.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Veneto
-
Padova, Veneto, Italy, 35127
- University of Padova
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
Written informed consent Renal transplantation candidate
Exclusion Criteria:
Double kidney transplantation Living donor kidney transplantation Hystory of heart failure
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: MOSTCARE UP
Clinician will be able to read MOSTCARE parameters and to choose the best treatment to adequate hemodynamics considering that current literature suggests a fluid IV expansion only if PPV > 12%
|
Clinician will be able to read MOSTCARE parameters and to choose the best treatment to adequate hemodynamics considering that current literature suggests a fluid IV expansion only if PPV > 12%
|
|
No Intervention: CLINICIAN EXPERIENCE
Fluid replacement will be made based on clinician experience
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Urine output in the first hour post unclamping (ml) in the two groups
Time Frame: first hour post unclamping during kydney transplanation
|
Urine output in the first hour post unclamping (ml) in the two groups
|
first hour post unclamping during kydney transplanation
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
1) Urine output in the first 24h (ml)
Time Frame: 24hour
|
1) Urine output in the first 24h (ml)
|
24hour
|
|
2) Need for haemodialysis in the first week (% of patients)
Time Frame: 7 days
|
2) Need for haemodialysis in the first week (% of patients)
|
7 days
|
|
3) First week creatinine and urea trend in the two groups
Time Frame: 7 days
|
3) First week creatinine and urea trend in the two groups
|
7 days
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009 Sep;37(9):2642-7. doi: 10.1097/CCM.0b013e3181a590da.
- Calixto Fernandes MH, Schricker T, Magder S, Hatzakorzian R. Perioperative fluid management in kidney transplantation: a black box. Crit Care. 2018 Jan 25;22(1):14. doi: 10.1186/s13054-017-1928-2.
- Schnuelle P, Johannes van der Woude F. Perioperative fluid management in renal transplantation: a narrative review of the literature. Transpl Int. 2006 Dec;19(12):947-59. doi: 10.1111/j.1432-2277.2006.00356.x.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 4423/AO/18
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Transplant Dysfunction
-
NCT03314376WithdrawnTransplant Dysfunction
-
NCT03602807Unknown
-
NCT06541002RecruitingSexual Dysfunction | Stem Cell Transplant Complications | Bone Marrow Transplant Complications
-
NCT04019353CompletedKidney Transplant Rejection | Kidney Transplant; Complications | Transplant; Complication, Rejection | Kidney Transplant Failure and Rejection | Transplant Dysfunction
-
NCT04643665CompletedTransplantation, Lung | Transplant Dysfunction
-
NCT06025240RecruitingFrailty | Kidney Transplant Rejection | Renal Transplant | Diagnosis | Kidney Transplant; Complications | Kidney Transplant | Renal Transplant Failure | Transplant Dysfunction
-
NCT05037838CompletedLiver Transplant; Complications | Myocardial Dysfunction
-
NCT07145944Not yet recruitingKidney Transplant Dysfunction | Kidney Transplant Failure and Rejection | Transplantation, Kidney
-
NCT05082077Enrolling by invitationLiver Diseases | Liver Transplant Disorder | Liver Dysfunction | Liver Transplant Rejection
-
NCT03855722RecruitingTransplant Dysfunction
Clinical Trials on Fluid replacement based on MOSTCARE up
-
NCT00479011Terminated
-
NCT01887262CompletedPeritoneal Dialysis, Continuous Ambulatory
-
NCT01129037CompletedHead and Neck Cancer
-
NCT02995317Unknown
-
NCT04983147Completed
-
NCT00686205CompletedHIV Positive | Healthy Donors
-
NCT07452354Not yet recruitingDiabete Mellitus | Diabetic Foot Ulcer (DFU) | Diabetic Foot Ulcer Treatment | Artificial Intelligence (AI) in Diagnosis
-
NCT01175317Completed
-
NCT06333574Not yet recruitingHypertension | Hemodialysis | Cardiovascular Events | Interdialytic Weight Gain | Life Quality | Dry Weight