Prospective 4D CTA of BAV Competence
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Contacts and Locations
Study Locations
-
-
Pennsylvania
-
Philadelphia, Pennsylvania, United States, 19104
- Recruiting
- University of Pennsylvania
-
Sub-Investigator:
- Alison Pouch
-
Contact:
- Jessica Nunez
- Phone Number: 215-829-3712
- Email: Jessica.Nunez@pennmedicine.upenn.edu
-
Contact:
- Kamryn Delaney
- Email: Kamryn.Delaney@pennmedicine.upenn.edu
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- At least 18 years of age
- Documented bicuspid aortic valve identified via clinical imaging (e.g., CT, MRI, or echocardiogram) with minimal calcification at the time of enrollment
- Participant must sign the informed consent form
Exclusion Criteria:
- Pregnancy (determined by point of care urine pregnancy test)
- Renal failure (estimated Glomerular Filtration Rate (eGFR) < 30), precluding them from receiving intravenous contrast)
- Documentation of previous intravenous contrast allergy (unless they are having a CT with steroid preparation as part of routine clinical care)
- Previous aortic valve replacement
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Cusp surface areas over the cardiac cycle
Time Frame: Through study completion, an average of 1 year
|
Surface area of each cusp in mm2 in one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Cusp height (geometric and effective)
Time Frame: Through study completion, an average of 1 year
|
Geometric and effective cusp height in mm in one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Cusp free margin length
Time Frame: Through study completion, an average of 1 year
|
Length of the free margin of each cusp in mm in one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Cusp thickness (including raphe thickness, if applicable)
Time Frame: Through study completion, an average of 1 year
|
Thickness of each cusp in mm in one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Commissural height
Time Frame: Through study completion, an average of 1 year
|
Height of each commissure in mm in one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Sino tubular junction size
Time Frame: Through study completion, an average of 1 year
|
Diameter of the sinotubular junction in mm in one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Size of the sinuses of Valsalva
Time Frame: Through study completion, an average of 1 year
|
Maximum diameter of the sinuses of Valsalva (mid-level of the aortic root) in mm in one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Ventriculoaortic junction size
Time Frame: Through study completion, an average of 1 year
|
Diameter of the ventriculoaortic junction in mm in one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Aortic annulus size
Time Frame: Through study completion, an average of 1 year
|
Diameter of the aortic cusp in mm measured in one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Coaptation height at diastole
Time Frame: Through study completion, an average of 1 year
|
Length of the coaptation zone of the cusps in mm when the valve is closed.
This measurement is made in one cardiac cycle (~0.6 - 1s in length) from the CT image.
|
Through study completion, an average of 1 year
|
|
Cusp displacement over the cardiac cycle
Time Frame: Through study completion, an average of 1 year
|
Total displacement of the center of the free margin of each cusp in mm during one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Cusp velocity over the cardiac cycle
Time Frame: Through study completion, an average of 1 year
|
Maximum velocity of the center of the free margin of each cusp in mm/s during one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
|
Size of the ascending aorta
Time Frame: Through study completion, an average of 1 year
|
Maximum diameter of the ascending aorta in cm during one cardiac cycle (~0.6 - 1s in length).
This measurement is made directly from the CT image.
|
Through study completion, an average of 1 year
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Development of aortic insufficiency and/or stenosis.
Time Frame: Through study completion, an average of 1 year
|
Degree of aortic insufficiency as measured on standard-of-care echocardiography
|
Through study completion, an average of 1 year
|
|
Development of aortic insufficiency and/or stenosis.
Time Frame: Through study completion, an average of 1 year
|
The need for surgical intervention for disease of the aortic valve and/or ascending aorta
|
Through study completion, an average of 1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
- Aortic Valve Disease
- Cardiovascular Diseases
- Heart Diseases
- Heart Valve Diseases
- Congenital Abnormalities
- Cardiovascular Abnormalities
- Heart Defects, Congenital
- Congenital, Hereditary, and Neonatal Diseases and Abnormalities
- Bicuspid Aortic Valve Disease
- Diagnostic Techniques and Procedures
- Diagnosis
- Tomography
- Diagnostic Imaging
- Radiography
- Image Interpretation, Computer-Assisted
- Radiographic Image Enhancement
- Image Enhancement
- Photography
- Tomography, X-Ray
- Tomography, X-Ray Computed
Other Study ID Numbers
Other Study ID Numbers
- 843190
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.