Efficacy of Everolimus-Eluting Versus Zotarolimus-Eluting Sten for Coronary Lesions in Acute Myocardial Infarction (EVERZOTA)

September 23, 2014 updated by: Yonsei University

Comparison of the Efficacy of Everolimus-Eluting Versus Zotarolimus-Eluting Stent for Coronary Lesions in Acute Myocardial Infarction

Most of the previous data regarding the efficacy of the everolimus-eluting stent (EES) was derived from studies comparing EES with bare metal stent (BMS) or EES with paclitaxel-eluting (PES). Although sirolimus-eluting stents (SES) have been shown to be the most efficacious drug regarding inhibition of neointima and late loss, there have been no previous head to head comparisons between EES and zotarolimus-eluting stent (ZES). Both everolimus and sirolimus are macrocyclic lactones that target the mTOR (mammalian target of rapamycin) to reduce vascular smooth muscle proliferation after vessel injury and therefore in principle may show similar results after stenting in humans. Data pooled from the EES arm that received follow up angiography in the SPIRIT III trial and the SES arm in the SIRIUS trial show similar rates of binary restenosis and late loss. However, the stent and polymer platform is not the same between the EES and ZES and it is reported that the EES system has the thinnest stent + polymer thickness (88.6um) of all of the previously KFDA-approved drug-eluting stent (DES). In addition, there are no data available on the efficacy of the EES and ZES in "real world" lesions other than the selected lesions studied in the previous trials, such as acute myocardial infarction.

Study Overview

Detailed Description

Previous randomized trials have shown the efficacy of a slow-release polymeric sirolimus-eluting stent (CYPHER, Cordis, Warren, NJ, USA), paclitaxel-eluting stent (TAXUS, Boston Scientific, Natick, MA, USA), and zotarolimus-eluting stent (Endeavor, Medtronic, Minneapolis, MN, USA) over bare metal stents in reducing neointimal hyperplasia, late luminal loss, and angiographic restenosis leading to decreased target lesion revascularization. The everolimus-eluting stent (XIENCE V, Abott Vascular, Santa Clara, CA, USA, PROMUS, Boston Scientific, Natick, MA, USA) is a newly developed drug eluting stent using the MULTILINK VISION® stent platform combined with the drug everolimus contained in a polymer coating.

In the first-in-man SPIRIT First clinical trial, XIENCE V showed a significant benefit over the bare metal VISION stent. Compared with late loss of 0.85 ± 0.36mm in the VISION arm, XIENCE V reduced late loss by 88% (0.10 ± 0.23mm). Also the clinical safety of XIENCE V was confirmed with a 6-month MACE rate of 7.7%. In the SPIRIT II clinical trial, which compared the efficacy and safety of the XIENCE V stent versus the TAXUS PECSS stent, the primary endpoint was met showing a non-inferiority of the XIENCE V compared with the TAXUS regarding in-stent late loss at 180 days. Actually, XIENCE V was superior to TAXUS and reduced in-stent late loss by 72% from a mean of 0.36 mm to 0.11 mm. In addition, analysis of other key clinical endpoints showed a lower rate of ischemia driven MACE (2.7% vs. 6.5% for XIENCE V vs. TAXUS) and protocol-defined stent thrombosis (0.5% vs. 1.3% for XIENCE V vs. TAXUS). The lower rate of ischemia driven MACE at 180 days was sustained through 1 year and there were no new instances of late stent thrombosis in either group up to 1 year.

The SPIRIT III RCT was a prospective, 2:1 randomized, active-controlled, single blinded, parallel, multi-center clinical evaluation of the XIENCE V Everolimus Eluting Coronary Stent System (XIENCE V EECSS) compared to TAXUS Paclitaxel Eluting Coronary Stent System (TAXUS PECSS) in the treatment of up to two de novo lesions. This pivotal clinical trial was designed to demonstrate the non-inferiority of the XIENCE V EECSS to the TAXUS PECSS. Patients were randomized 2:1 to XIENCE V or TAXUS and the primary endpoint was in-segment late loss at 240 days. The results showed a mean in-segment late loss of 0.14mm for XIENCE V and 0.28 mm for TAXUS (p<0.001 for non-inferiority, p=0.0037 for superiority). The secondary endpoint, which was ischemia-driven target vessel failure (TVF), was 7.6% for XIENCE V and 9.7% for TAXUS, confirming the non-inferiority of XIENCE V. Furthermore, the rate of definite and probable stent thrombosis was 1.1% and 0.6% for XIENCE V and TAXUS, respectively.

With a recent approval of new DES, zotarolimus-eluting stent (Endeavor, Medtronic, Minneapolis, MN), other comparison studies have been conducted to compare Endeavor zotarolimus-eluting stent with the sirolimus-eluting stent and paclitaxel-eluting stent. zotarolimus and sirolimus share some common structural and biological properties. In vitro data suggest that sirolimus and tetrazole containing rapamycin analogs have similar inhibitory effects in a mixed lymphocyte reaction assay. The ENDEAVOR clinical trials are currently in progress to evaluate a phosphoryl choline (PC)-coated zotarolimus-eluting stent(ZES) for the prevention of restenosis. The Endeavor zotarolimus-eluting stent utilizes a cobalt alloy balloon-expandable stent (Driver; Medtronic) with a geometry similar to the stainless steel stent used in this preliminary study (S7; Medtronic). The Endeavor ZES also employees a PC strut surface coating as the drug delivery reservoir with a dose of 10 g/mm of ABT-578. The Endeavor (ZES), however, differs from the stent used in this experimental study by the addition of a drug-free PC topcoat to serve as a diffusion barrier to retard drug release from the polymer reservoir. Angiographic analysis at 4 months in the 100-patient focal de novo lesion ENDEAVOR I feasibility study demonstrated a mean in-stent percent diameter stenosis of approximately 14% and a late lumen loss of 0.3 mm with a low frequency of target lesion revascularization (1%). The clinical outcomes from the ENDEAVOR II (1,500 patients randomized to ABT-578 or bare metal stent) and the ENDEAVOR III (436 patients randomized 3:1 to ABT-578 or Cypher) trials as well as other ongoing studies showed efficacy of the PC-coated ABT-578-eluting stent. In ENDEAVOR III study, the Endeavor stent had larger late loss and higher binary restenosis in both the analysis segment and stented segment.

Most of the previous data regarding the efficacy of the EES was derived from studies comparing EES with BMS or EES with PES. Although sirolimus eluting stents (SES) have been shown to be the most efficacious drug eluting stent regarding inhibition of neointima and late loss, there have been no previous head to head comparisons between EES and ZES. Both everolimus and sirolimus are macrocyclic lactones that target the mTOR (mammalian target of rapamycin) to reduce vascular smooth muscle proliferation after vessel injury and therefore in principle may show similar results after stenting in humans. Data pooled from the EES arm that received follow up angiography in the SPIRIT III trial and the SES arm in the SIRIUS trial show similar rates of binary restenosis and late loss. However, the stent and polymer platform is not the same between the EES and ZES and it is reported that the EES system has the thinnest stent + polymer thickness (88.6um) of all of the previously KFDA-approved DES. In addition, there are no data available on the efficacy of the EES and ZES in "real world" lesions other than the selected lesions studied in the previous trials, such as acute myocardial infarction.

Study Type

Interventional

Enrollment (Actual)

461

Phase

  • Phase 4

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Wonju, Korea, Republic of, 220-701
        • Yonsei University Wonju College of Medicine; Wonju Severance Christian Hospital

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Age > 18 years
  • Chest pain duration more than 10 minutes
  • At least on of the following criteria
  • A. ECG change (T inversion, ST depression or ST elevation)
  • B. Cardiac enzyme elevation more than upper normal limit
  • Significant coronary artery stenosis (>50% by visual estimate)
  • The patient or guardian agrees to the study

Exclusion Criteria:

  • Stent thrombosis
  • Left main disease
  • Cardiogenic shock
  • Cronic kidney disease or renal failure requiring hemodialysis
  • History of bleeding diathesis or known coagulopathy
  • Gastrointestinal or genitourinary bleeding within the prior 3 months
  • History of major surgery within 2 months
  • Planned surgery requiring cessation of clopidogrel within 12 months of percutaneous coronary intervention (PCI)
  • Serious patients whose life expectancy <1 year or severe infectious status

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: TREATMENT
  • Allocation: RANDOMIZED
  • Interventional Model: PARALLEL
  • Masking: NONE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
ACTIVE_COMPARATOR: Xience V stent group
Xience V (Everolimus eluting stent) insertion in patients with acute myocardial infarction
Comparison of the safety and efficacy between everolimus-eluting stent and zotarolimus-eluting stent resolute
Other Names:
  • Xience V
  • Promus or Promus element
ACTIVE_COMPARATOR: Endeavor resolute group
Endeavor resolute (Zotarolimus eluting stent) insertion in patients with acute myocardial infarction
Comparison of the safety and efficacy between everolimus-eluting stent and zotarolimus-eluting stent resolute
Other Names:
  • Endeavor resolute

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Device-oriented Composite Outcome
Time Frame: Two year
defined as a composite of cardiac death, Myocardial infarction not clearly attributable to a nontarget vessel and target lesion revascularization
Two year

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Device-oriented Composite Outcome
Time Frame: Two years
defined as a composite of all-cause mortality, any MI (includes non-target vessel territory) and repeat revascularization (includes all target and non-target vessel)
Two years
Stent Thrombosis
Time Frame: Two years
Definite and probable stent thrombosis
Two years
Any Bleeding
Time Frame: Two year
Two year

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Collaborators

Investigators

  • Principal Investigator: Seung-Hwan Lee, MD, PhD, Division of Cardiology, Department of Internal Medicine, Yonsei University Wonju College of Medicine, Wonju Severance Christian Hospital

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

January 1, 2009

Primary Completion (ACTUAL)

March 1, 2013

Study Completion (ACTUAL)

March 1, 2013

Study Registration Dates

First Submitted

April 27, 2011

First Submitted That Met QC Criteria

May 2, 2011

First Posted (ESTIMATE)

May 4, 2011

Study Record Updates

Last Update Posted (ESTIMATE)

September 29, 2014

Last Update Submitted That Met QC Criteria

September 23, 2014

Last Verified

September 1, 2014

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Myocardial Infarction

Clinical Trials on Everolimus eluting stent

Subscribe