Laryngeal Mask Supreme During Laparoscopic Gynecologic Surgery

February 8, 2017 updated by: Sule Ozbilgin, Dokuz Eylul University

Application of Endotracheal Intubation and Laryngeal Mask Supreme Without Neuromuscular Blocker in Laparoscopic Gynecologic Surgery

Laryngeal mask (LM) use in gynecological laparoscopy, contrary to widespread opinion, does not increase the incidence of gastric aspiration, the failure of ventilation or the risk of pulmonary aspiration . LM is presented as an alternative to endo tracheal tube (ETT) in spontaneous or positive pressure ventilation (PPV) . LM has gained widespread popularity in England for gynecological laparoscopic procedures. In addition in many previous studies LM has been successfully shown to provide appropriate lung ventilation in laparoscopic surgical interventions .Miller et al. compared the use of ETT, LM-P laparoscopic gynecological interventions and identified advantages to LM use. The most important of these advantages was that, contrary to tracheal tube techniques for laparoscopic surgeries, use of supraglottic laryngeal devices or neuromuscular blocker agents (NBA) were not required during placement. Thus for laparoscopic surgeries, compared with the ETT technique, without the need for supraglottic laryngeal devices or muscular relaxants, it is easily placed and reduces the time spent in the operating room.

Our aim; to compare the use of LM-S and ETT without neuromuscular agents for laparoscopic gynecological intervention with positive pressure ventilation from a surgical viewpoint and in terms of effect on ventilation parameters.

Secondary aim, comparison of airway morbidity with endotracheal intubation and supraglottic.

Study Overview

Status

Completed

Conditions

Detailed Description

This prospective, randomized and double-blind study received permission from "Dokuz Eylül University Medical Faculty Non-Interventional Research Ethics Committee" and after obtaining patients' informed consent, 100 patients with American society of anesthesiologists (ASA) classification group I-II, between 18-65 years, undergoing elective laparoscopic gynecological surgery were included.

Patients were divided into:

Group 1=>ETT (50 patients) Group 2=>LM-S (50 patients) Patients and surgeons performing the operation were not aware of which airway device was used. The patients in the groups were determined by block randomized methods.

Patients taken to the surgical room were given standard monitoring (non-invasive blood pressure measurements, electrocardiogram, and peripheral oxygen saturation measurements) before anesthesia induction. For preoperative sedation 0.02 mg/kg midazolam IV was administered.

Patients were preoxygenated with 6 L/min oxygen for 3 minutes through a face mask.

For anesthesia induction after 2 minutes of 0.2 µg/kg/min remifentanil and 6 mg/kg/hr propofol infusion, IV 1-2 mg/kg propofol was administered. After induction patients were ventilated with 6 L/min 100% fraction of inspired oxygen inspired oxygen fraction oxygen through a face mask. Anesthesia depth was standardized in all patients using bispectral index monitoring. Bispectral index values were held between 40-60. Bispectral index values were maintained in this interval by increasing or decreasing propofol infusion by 1 mg/kg.

Airway devices were inserted by two researchers with more than 5 years experience.

During airway device placement according to patient reactions an extra dose of 0.5 mg/kg propofol was given if necessary.

Anesthetic maintenance was provided by 50% O2/air mixture with 0.1-0.4 µg/kg/min remifentanil and 50-150 µg/kg/hr (3-9 mg/kg/hr) propofol IV infusion.

Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based gel without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For <50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted.

After LM-S placement the cuff was inflated with air so as to have a pressure below 60 centimeters of water (cuff pressure manometer, Rusch, Germany). Two minutes after LM-S placement, before insufflation, 10 minutes after insufflation and trendelenburg position, before desufflation and before LM-S removal, cuff pressure was measured repeatedly and recorded. At the same time intervals in the ETT group, ETT cuff pressure was measured.

In the ETT group for women no. 7-7.5 tube was used. The ETT cuff was inflated until the leak sound ceased. It was measured with a manometer to remain between 20-30 centimeters of water.

Successful placement of LM or ETT was confirmed by square-shaped waves observed on the capnogram, easy ventilation of the respiration balloon and visible chest movements. After successful placement of the airway device, it was covered to prevent observation of which device was used.

The length of time for successful placement (duration from mouth opening to first successful ventilation), number of tries, and ease of placement were recorded. Ease of placement was evaluated by the anesthetist in charge of the airway as easy, hard or unsuccessful (alternative airway management).

In a situation where airway provision was unsuccessful after 3 tries, patients without placement of LM-S or who could not be intubated were switched to the other group and airway management was provided.

For oropharyngeal leak test after the expiratory valve was closed air was shut off, O2 was reduced to 3 L/min and the first pressure value when a leak sound was heard was recorded as the oropharyngeal leak pressure. To prevent exposure of the lungs to barotrauma, when the peak inspiratory pressure reached 40centimeters of water the expiratory valve was opened and the test was concluded. This test was repeated before peritoneal insufflation, 10 minutes later and immediately before desufflation and was completed by a researcher blind to the type of airway device inserted.

Positive pressure respiration was begun by using a ring system, 2-4 L/min fresh gas flow and 0.5 volume controlled 6-8 ml/kg tidal volume and 10 respirations/min frequency. Positive end expiratory pressure was not administered and I:E ratio was adjusted to 1:2. ETCO2 was held between 35-45 mmHg, if necessary first respiration frequency was increased then tidal volume was increased. Permission was given for CO2 insufflation for the laparoscopic intervention with peritoneal interior pressure of 15 mmHg.

Two minutes after LM-S or ETT placement, before insufflation, 10 minutes after insufflation and trendelenburg position, immediately before peritoneal desufflation and before airway device removal, ventilation parameters were evaluated.

Respiratory measurements to be recorded: Tidal volume (TV), respiration number (RN), peripheral oxygen saturation (SPO2), end-tidal carbon dioxide pressure (PETCO2), peak airway pressure (P peak), mean airway pressure (P mean) and expiration volume per minute (VE).

Hemodynamic measurements to be recorded: (simultaneous to the measurements above and additionally before induction) Systolic arterial pressure (SAP), diastolic arterial pressure (DAP), mean arterial pressure (MAP) and heart rate (HR).

Evaluation related to gastric tube:

Immediately after airway device placement using either the LM-S drainage tube or in intubated patients using a 14 F orogastric probe within the airway, the stomach was reached and the gastric contents were aspirated. Ease of placement and amount of fluids aspirated were recorded. Ease of placement was classified by the person who inserted the orogastric probe as very easy, easy, difficult and very difficult.

The number of interventions with Verres needle, initial intra-abdominal pressure, duration to reach intra-abdominal pressure of 15 mmHg, and insufflated volume of CO2 were recorded. Sufficiency of pneumoperitoneum (sufficient/insufficient), and quality of airway provision were evaluated by the surgeon who was blind to the airway device used by giving points between 1-4.

Immediately after the intra-abdominal laparoscopic intervention and immediately before peritoneal insufflation was ended, gastric distension was evaluated by a surgeon blind to the airway device used between 0-10 (0=empty stomach, 10=distension obstructing the surgical field) and the difference between the scores at the start and end of the operation was recorded.

When the patient cooperated LM-S or ETT was removed and total anesthesia duration and peritoneal insufflation duration was recorded. Possible complications that could develop during airway device removal (coughing, vomiting, laryngeal stridor, laryngeal spasm or requirement for airway intervention) were recorded.

After laryngeal supra glottic airway device removal the presence of blood was evaluated as

  1. no blood
  2. trace amounts of blood
  3. clear amount of blood Revived patients were taken to the recovery unit and a blind researcher evaluated the patients' throat pain, hoarseness and presence of difficulty swallowing in the 1st and 24th hours. To evaluate throat pain the visual analogue scale was used.

Study Type

Interventional

Enrollment (Actual)

108

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Narlıdere
      • Izmi̇r, Narlıdere, Turkey, 35320
        • Sule Ozbilgin

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

14 years to 61 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

Female

Description

Inclusion Criteria:

  • ASA classification group I-II
  • Between 18-65 years
  • Undergoing elective laparoscopic gynecological surgery

Exclusion Criteria:

  • Individuals with any neck and upper respiratory pathology
  • Individuals at risk of gastric content regurgitation/aspiration (previous upper gastrointestinal surgery, known hiatus hernia, gastroesophageal reflux, history of peptic ulcer, full stomach, pregnancy)
  • Individuals with low pulmonary compliance or high airway resistance (chronic lung diseases)
  • Obese patients (BMI >35)
  • Individuals with sore throat, dysphagia and dysphonia
  • Individuals with possibility or history of difficult airway
  • Operation time planned for more than 4 hours

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Other
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Double

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Group ETT
Group endotracheal tube In the endotracheal tube group for women no. 7-7.5 tube will use. ETT:Rüschelit, Teleflex Medical Sdn. Bhd. Malaysia. Ref:112482
ETT
Other Names:
  • Group ETT
Experimental: Group LMS
Laryngeal mask airway-supreme Group In the LMS group for <50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) will insert.
Group LM-S (Laryngeal Mask Airway-Supreme)Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based gel without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For <50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted.
Other Names:
  • Group LM-S

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Asses to Ventilation Parameters
Time Frame: intraoperative period
tidal volume (ml) at certain time intervals T1= 2 minutes after airway device insertion T2= 10 minutes after insufflation T3= Before desufflation T4= Before removal of airway device
intraoperative period
Asses to Peak Pressure
Time Frame: intraoperative period
peak pressure (cmH20) at certain time intervals T1= 2 minutes after airway device insertion T2= 10 minutes after insufflation T3= Before desufflation T4= Before removal of airway device
intraoperative period
Asses to Mean Pressure
Time Frame: during procedure
mean pressures within the times below (cmH20) T1= 2 minutes after airway device insertion T2= 10 minutes after insufflation T3= Before desufflation T4= Before removal of airway device
during procedure

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Evaluation of Gastric Distention
Time Frame: Baseline
To provide the adequate gastric distention of either the LM-Supreme or the tracheal tube, as assigned. Gastric distension was evaluated by a surgeon blind to the airway device used between 0-10 (0=empty stomach, 10=distension obstructing the surgical field)
Baseline
Quality of View According to Surgeon by Rate Scale
Time Frame: intraoperative period

Quality of surgical view will be assessed with points from 1 to 4 by the surgeon blind to the airway device by Rate Scale.

Grade of quality of view were evaluated between 1-4 points (1-poor to 4-excellent)

intraoperative period
Ease of Orogastric Tube Placement Classification
Time Frame: Baseline
Ease of placement was classified by the person who inserted the orogastric tube as very easy, easy, difficult or very difficult.
Baseline
Haemodynamic Response to Insertion of Airway Device
Time Frame: Baseline
Systolic blood pressure and heart rate at two minutes after LM-S placement, before insufflation, 10 minutes after insufflation and trendelenburg position, before desufflation and before LM-S removal .
Baseline
Incidence of Post-operative Sore Throat
Time Frame: Baseline
Patients were asked about the presence of sore throat - defined as the presence of constant pain in the throat, independent of swallowing, 1 hr and 24 hr after the end of surgery.
Baseline

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: SULE OZBİLİGİN, M.D., STUDY DESİGN

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

May 1, 2013

Primary Completion (Actual)

March 1, 2015

Study Completion (Actual)

April 1, 2015

Study Registration Dates

First Submitted

January 31, 2014

First Submitted That Met QC Criteria

April 26, 2014

First Posted (Estimate)

April 29, 2014

Study Record Updates

Last Update Posted (Actual)

March 28, 2017

Last Update Submitted That Met QC Criteria

February 8, 2017

Last Verified

February 1, 2017

More Information

Terms related to this study

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Anaesthesia

Clinical Trials on Endotracheal Tube

Subscribe