Comparison of Laryngeal Mask Airway Supreme and Endotracheal Tube In Patients Undergoing Gynecological Laparoscopy Surgery

December 20, 2017 updated by: Sule Ozbilgin, Dokuz Eylul University
Endotracheal Tube (ETT) is still preferred for laparoscopic surgeries because of the fear of pulmonary aspiration and inadequate ventilation. Laryngeal mask Supreme (LM-S) is a single use device and the presence of a drain tube allows to separate the gastrointestinal and respiratory tracts. We planned to compare ventilation parameters and gastric distension scores of with LM-S vs ETT during laparoscopic gynecological surgery.

Study Overview

Status

Completed

Conditions

Detailed Description

This prospective, randomized and double-blind study received permission from "Dokuz Eylül University Medical Faculty Non-Interventional Research Ethics Committee" and after obtaining patients' informed consent, 100 patients with American society of anesthesiologists (ASA) classification group I-II, between 18-65 years, undergoing elective laparoscopic gynecological surgery were included.

Patients were divided into:

Group 1=>ETT (Endo tracheal group) (50 patients) Group 2=>LM-S (Laryngeal mask Supreme) (50 patients) Patients and surgeons performing the operation were not aware of which airway device was used. The patients in the groups were determined by block randomized methods.

Patients taken to the surgical room were given standard monitoring (non-invasive blood pressure measurements, electrocardiogram, and peripheral oxygen saturation measurements) before anesthesia induction. For preoperative sedation 0.02 mg/kg midazolam IV was administered.

Patients were preoxygenated with 6 L/min oxygen for 3 minutes through a face mask.

For anesthesia induction after 2 minutes of 0.2 µg/kg/min remifentanil and 6 mg/kg/hr propofol infusion, IV 1-2 mg/kg propofol , 0,5 mg/kg rocuronium bromide was administered. After induction patients were ventilated with 6 L/min 100% oxygen through a face mask.

Airway devices were inserted by two researchers with more than 5 years experience.

Anesthetic maintenance was provided by 50% O2/air mixture with 0.1-0.4 µg/kg/min remifentanil and 50-150 µg/kg/hr (3-9 mg/kg/hr) propofol IV infusion (24).

Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based gel without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For <50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted.

After LM-S placement the cuff was inflated with air so as to have a pressure below 60 water of centimeter (cmH20) (cuff pressure manometer, Rusch, Germany). Two minutes after LM-S placement, before insufflation, 10 minutes after insufflation and trendelenburg position, before desufflation and before LM-S removal, cuff pressure was measured repeatedly and recorded. At the same time intervals in the ETT group, ETT cuff pressure was measured.

In the ETT group for women no. 7-7.5 tube was used. The ETT cuff was inflated until the leak sound ceased. It was measured with a manometer to remain between 20-30 water of centimeter (cmH20).

Successful placement of LM-S or ETT was confirmed by square-shaped waves observed on the capnogram, easy ventilation of the respiration balloon and visible chest movements. After successful placement of the airway device, it was covered to prevent observation of which device was used.

The length of time for successful placement (duration from mouth opening to first successful ventilation), number of tries, and ease of placement were recorded. Ease of placement was evaluated by the anesthetist in charge of the airway as easy, hard or unsuccessful (alternative airway management).

In a situation where airway provision was unsuccessful after 3 tries, patients without placement of LM-S or who could not be intubated were switched to the other group and airway management was provided.

For oropharyngeal leak test after the expiratory valve was closed air was shut off, O2 was reduced to 3 L/min and the first pressure value when a leak sound was heard was recorded as the oropharyngeal leak pressure. To prevent exposure of the lungs to barotrauma, when the peak inspiratory pressure reached 40 cmH2O the expiratory valve was opened and the test was concluded. This test was repeated before peritoneal insufflation, 10 minutes later and immediately before desufflation and was completed by a researcher blind to the type of airway device inserted.

Positive pressure respiration was begun by using a ring system, 2-4 L/min fresh gas flow and 0.5 fraction of inspired oxygen (FiO2) volume controlled 6-8 ml/kg tidal volume and 10 respirations/min frequency. PEEP was not administered and I:E ratio was adjusted to 1:2. ETCO2 was held between 35-45 mmHg, if necessary first respiration frequency was increased then tidal volume was increased. Permission was given for CO2 insufflation for the laparoscopic intervention with peritoneal interior pressure of 15 mmHg.

Two minutes after LM-S or ETT placement, before insufflation, 10 minutes after insufflation and trendelenburg position, immediately before peritoneal desufflation and before airway device removal, ventilation parameters were evaluated.

Respiratory measurements to be recorded: Tidal volume (TV), respiration number (RN), peripheral oxygen saturation (SPO2), end-tidal carbon dioxide pressure (PETCO2), peak airway pressure (P peak), mean airway pressure (P mean) and expiration volume per minute (VE).

Hemodynamic measurements to be recorded: (simultaneous to the measurements above and additionally before induction) Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) and heart rate (HR).

Evaluation related to gastric tube:

Immediately after airway device placement using either the LM-S drainage tube or in intubated patients using a 14 Ch orogastric probe within the airway, the stomach was reached and the gastric contents were aspirated. Ease of placement and amount of fluids aspirated were recorded. Ease of placement was classified by the person who inserted the orogastric probe as very easy, easy, difficult and very difficult.

Immediately after the intra-abdominal laparoscopic intervention and immediately before peritoneal insufflation was ended, gastric distension was evaluated by a surgeon blind to the airway device used between 0-10 (0=empty stomach, 10=distension obstructing the surgical field) and the difference between the scores at the start and end of the operation was recorded .

When the patient cooperated LM-S or ETT was removed and total anesthesia duration and peritoneal insufflation duration was recorded. Possible complications that could develop during airway device removal (coughing, vomiting, laryngeal stridor, laryngeal spasm or requirement for airway intervention) were recorded.

After LM-S removal the presence of blood was evaluated as

  1. no blood
  2. trace amounts of blood
  3. clear amount of blood Revived patients were taken to the recovery unit and a blind researcher evaluated the patients' throat pain, hoarseness and presence of difficulty swallowing in the 1st and 24th hours. To evaluate throat pain the visual analogue scale was used.

Study Type

Interventional

Enrollment (Actual)

100

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Narlıdere
      • Izmi̇r, Narlıdere, Turkey, 35320
        • Sule Ozbilgin

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 65 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

Female

Description

Inclusion Criteria:

  • ASA classification group I-II
  • Between 18-65 years
  • Undergoing elective laparoscopic gynecological surgery

Exclusion Criteria:

  • Individuals with any neck and upper respiratory pathology
  • Individuals at risk of gastric content regurgitation/aspiration (previous upper gastrointestinal surgery, known hiatus hernia, gastroesophageal reflux, history of peptic ulcer, full stomach, pregnancy)
  • Individuals with low pulmonary compliance or high airway resistance (chronic lung diseases)
  • Obese patients (BMI >35)
  • Individuals with sore throat, dysphagia and dysphonia
  • Individuals with possibility or history of difficult airway
  • Operation time planned for more than 4 hours

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Screening
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Double

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Group ETT (endo tracheal tube)
Group ETT (Endotracheal tube Group). In the ETT group for women no. 7-7.5 tube will use. ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
ETT:Ruschelit, Teleflex Medical Snd. Bhd. Malaysia. Ref:112482
Other Names:
  • Device: Endotracheal Tube (ETT)
Experimental: Group LM-S(Laryngeal mask supreme Group)
Experimental: Group LM-S Group LM-S (Laryngeal mask supreme Group) For <50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) will insert.

Before LM-S was inserted, to lubricate the surface in contact with the palate a water-based K-YTM gel (Johnson & Johnson Ltd. Maidenhead, UK) without local anesthetic was applied to completely cover the LM-S cuff. Depending on the patient's body weight For <50 kg, no. 3 Between 50-70 kg, no. 4 Between 70-100 kg, no. 5 LM-S (The Laryngeal Mask Company Limited, Singapore) was inserted.

Other Names:

LM-S (The Laryngeal Mask Company Limited, Singapore) serial number: 175030 lot: hmabw7

Other Names:
  • Group LM-S (laryngeal mask group).

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Mean Airway Pressures
Time Frame: At first and last 10 minutes of pneumoperitoneum

The measure is the mean airway pressure (cmH2O):

T1= 2 minutes after airway device insertion T2= 10 minutes after insufflation T3= Before desufflation T4= Before removal of airway device

At first and last 10 minutes of pneumoperitoneum

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Evaluation of Gastric Distention
Time Frame: Baseline
To provide the adequate gastric distention of either the LM-Supreme or the tracheal tube, as assigned. Gastric distension was evaluated by a surgeon blind to the airway device used between 0-10 (0=empty stomach, 10=distension obstructing the surgical field)
Baseline
Throat Pain According to Visual Analogue Scale
Time Frame: postoperative 1st and 24th hours
Patients were asked about the presence of sore throat - defined as the presence of constant pain in the throat, 1 hr and 24 hr after the end of surgery according to Visual Analogue Scale. (range min. 0, max.10; >4 analgesia planned)
postoperative 1st and 24th hours

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: BAHAR KUVAKİ, M.D., Dokuz Eylül University, School of Medicine, Department of Anesthesiology and Reanimation

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

April 1, 2012

Primary Completion (Actual)

April 1, 2013

Study Completion (Actual)

May 1, 2013

Study Registration Dates

First Submitted

April 26, 2014

First Submitted That Met QC Criteria

April 30, 2014

First Posted (Estimate)

May 1, 2014

Study Record Updates

Last Update Posted (Actual)

December 21, 2017

Last Update Submitted That Met QC Criteria

December 20, 2017

Last Verified

December 1, 2017

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

Undecided

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Anaesthesia

Clinical Trials on Endotracheal Tube

Subscribe