Hemodialysis Blood Flow and Urea Clearance

December 7, 2015 updated by: University of British Columbia

Examining the Effect of Blood Flow Rate on Hemodialysis Urea Clearance

The study purpose is to determine whether two different hemodialysis blood flow rates each meet national dialysis standards for urea clearance. Urea is used as the primary marker of dialysis adequacy. It is an experimental study with a crossover design of minimum 38 participants. Participants will be selected from the accessible pool of end-stage renal disease clients at the Vancouver Community Dialysis Unit. The participants will dialyse at each pre-determined blood flow rate (320 mL/min and 380 mL/min) for two weeks each. Two forms of urea clearance data will be collected: one value that is routinely calculated by the dialysis machine and recorded on client treatment logs, and another that is calculated in a lab from blood samples.

Study Overview

Status

Completed

Intervention / Treatment

Detailed Description

Design This quasi-experimental study involves the independent variable of blood flow rate (Qb), measured in mL/min, and the dependent variable of dialysis clearance, measured by Kt/V and URR (urea reduction ratio). Control and randomization will be manifested in a crossover design, which provides the benefit of separating treatment effects from period effects (Wellek & Blettner, 2012). Participants will be randomly assigned - by way of selecting names from an envelope - to one of two groups: A, which dialyses first at 320 mL/min; or B, at 380 mL/min. Each study period will consist of two weeks (6 sessions, 24 hours of dialysis) at each Qb. Because urea clearance is immediate, six treatments at each Qb will reflect accurate data on Kt/V and URR (Dr. John Duncan, 2014, personal communication). Although carryover effects are not of concern to this study as participants routinely dialyse three times per week, wherein urea levels naturally rise between routine treatments, a washout phase of one week between study periods will occur, as is recommended for an effective crossover design (Wellek & Blettner, 2012).

Sample

The target and sample population are end-stage renal disease patients dialysing with an arteriovenous fistula (AVF) at the Vancouver Community Dialysis Unit. Power analysis was conducted by the Centre for Health Evaluation and Outcome Sciences (CHEOS). To ensure a Kt/V of 1.3 and URR of 70% can be estimated with a confidence interval of 95%, a minimum sample size of 34 participants is required. An additional 10% is necessary to account for attrition. Because randomization will occur with study period assignment, purposive sampling will be used to select participants from the accessible pool (estimated at 60 patients), until 38 participants are identified. The inclusion criteria are:

Dialysing for greater than six months to ensure access patency, viability, and stability; Undergoing thrice weekly, four-hour dialysis sessions for uniform dialysis duration; Dialysing with an AVF, either brachio-cephalic or radio-cephalic; no central venous catheters, arteriovenous grafts, or femoral AVFs due to differences in access flows and vessel quality; BLOOD FLOW RATE 5 Dialysing with 15g needles as organization policy restricts greater flow rates with smaller needle gauge; Dialysing with a dialysate flow (Qd) of 500 mL/min to reduce the possibility of clearance being attributable to differences in Qd; Maintaining transonic vascular access flows of >600 mL/min for the past 6 months, per KDOQI (NKF, 2006) minimum flow guidelines, to ensure access patency; Not part of any other research study that would interfere with dialysis treatment.

Data Collection Hourly documentation of Qb is routine protocol in the HD (hemodialysis) unit, along with Kt/V at each treatment termination. URR is routinely drawn every 6 weeks, however during this study it will be drawn weekly, on each third treatment. Standard URR blood draw protocol will be followed: a pre- and post- dialysis blood specimen will be collected and sent, along with the corresponding requisition, for analysis and calculation. A research account will be opened with LifeLabs (local laboratory service) and all research requisitions and blood will be coded and billed to the research study. Per unit protocol, blood draws will be written in the unit diary for nurse awareness, and blood collection tubes and requisition placed in participants' charts the night prior to treatment. Once weekly, the researchers will photocopy the participants' treatment run logs, along with the urea lab report, and data will be inputted into a CHEOS-approved excel spreadsheet. Along with Qb and Kt/V, collected data will include participants' blood pressure, dialysate flow rate, dialysis duration, needle gauge and cannulation, and occurrence of any intradialytic complications.

Data Analysis Data analysis will be conducted by CHEOS.

Study Type

Interventional

Enrollment (Actual)

24

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • British Columbia
      • Vancouver, British Columbia, Canada, V5Z 1M9
        • University of British Columbia, Division of Nephrology

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Child
  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

Participants will be selected from the Vancouver Community Dialysis Unit.

The inclusion criteria for participant selection will be:

  1. Dialysing for greater than six months to ensure access patency, viability, and stability;
  2. Undergoing thrice weekly, four-hour dialysis sessions for uniform dialysis duration;
  3. Dialysing with an arteriovenous fistula, either brachio-cephalic or radio-cephalic, to control variances in blood flow rates related to vascular access;
  4. Dialysing with 15g needles as organization policy restricts greater flow rates with smaller needle gauge;
  5. Dialysing with a dialysate flow (Qd) of 500 mL/min to reduce the possibility of clearance being attributable to differences in Qd;
  6. Maintaining transonic vascular access flows of >600 mL/min for the past 6 months, per Kidney Dialysis Outcomes Quality Initiative (KDOQI) (NKF, 2006) minimum flow guidelines, to ensure access patency.

Exclusion Criteria:

Patients who speak a language other than English, Cantonese, Mandarin, or Punjabi will be excluded due to funding constraints for providing translated informed consent documents. Informed consent documents will only be available in the languages listed above, which are the most common languages spoken/read at the dialysis unit.

Patients who dialyse with a central venous catheter, arteriovenous graft, or femoral arteriovenous fistula will not be invited to participate due to potential confounding from known differences in access flows and vessel quality that may impact clearance values.

Patients who are involved in any other research study that would interfere with their dialysis treatment would be excluded from the study.

Patients who are hemodynamically unstable (e.g.: frequent 'crashing' due to severe hypotension) will be excluded due to the instability this would pose on achieving their prescribed dialysis time (e.g.: if they crash, they may be taken off dialysis early) and resulting data.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Non-Randomized
  • Interventional Model: Crossover Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Targeted blood flow rate 320 ml/min
Hemodialysis blood flow will be targeted at 320 ml/min during hemodialysis for two weeks
The impact of blood flow rates of 320 ml/m and 380 ml/m will be compared to determine any impact on hemodialysis urea clearance
Experimental: Targeted blood flow rate 380 ml/min
Hemodialysis blood flow will be targeted at 380 ml/min during hemodialysis for two weeks
The impact of blood flow rates of 320 ml/m and 380 ml/m will be compared to determine any impact on hemodialysis urea clearance

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
Urea clearance
Time Frame: Two weeks of dialysis at each blood flow rate
Two weeks of dialysis at each blood flow rate

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: John A Duncan, MSc MD FRCPC, University of British Columbia

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

May 1, 2015

Primary Completion (Actual)

July 1, 2015

Study Completion (Actual)

August 1, 2015

Study Registration Dates

First Submitted

February 4, 2015

First Submitted That Met QC Criteria

June 24, 2015

First Posted (Estimate)

June 29, 2015

Study Record Updates

Last Update Posted (Estimate)

December 9, 2015

Last Update Submitted That Met QC Criteria

December 7, 2015

Last Verified

December 1, 2015

More Information

Terms related to this study

Other Study ID Numbers

  • H14-01931

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on End Stage Renal Failure on Dialysis

Clinical Trials on Hemodialysis blood flow

Subscribe