Comparison of Non-Invasive Methods of Assessing Fluid Responsiveness in ED and ICU Patients (FRESEDICU)

April 6, 2020 updated by: Alan Chiem, M.D., Olive View-UCLA Education & Research Institute

Accurate assessment of fluid responsiveness (FRes) is central to guiding fluid management in septic and critically ill patients. As evidence accumulates that both inadequate and excessive fluid resuscitation are associated with increased morbidity and mortality, it is simultaneously becoming increasingly clear that current widely used methods to predict FRes are of questionable accuracy. The optimal technique to predict FRes would be a non-invasive point-of-care test with not only a high degree of accuracy, but also one which requires minimal training to perform correctly and may be easily performed repeatedly for serial evaluation of FRes during the ongoing management of the critically ill patient.

To date, three major ultrasonographic modalities have emerged as viable candidates for the bedside assessment of FRes: 1) measurement of dynamic changes in inferior vena caval diameter (IVC-CI), 2) measurement of dynamic changes in peripheral arterial waveform derived variables (PA Doppler), and 3) echocardiographic measurement of dynamic changes in left ventricular outflow tract waveform derived variables (LVOT Doppler). In this study, the investigators will perform the first direct comparison of techniques representing all three of the above modalities in the prediction of FRes against a non-invasive bioreactance cardiac output monitor (the Cheetah NICOM™), which has been extensively validated against gold-standard invasive methods of cardiac output measurement. The investigators will compare the accuracy of these modalities in both spontaneously breathing and mechanically ventilated patients using passive leg raise testing (PLR) as a surrogate for volume challenge. In addition, the investigators will also elicit information from the treating physician(s) on their clinical assessment of FRes.

The investigators will recruit adult patients in the ED and ICU with sepsis, who have received an initial bolus of 20-30 cc/kg of IV fluid, and can tolerate the PLR and US procedures. Prior to US and NICOM measurement, investigators will ask the attending physician managing the patient regarding their assessment of the their fluid status. Then, separate investigators will perform US and NICOM measurements independently to ensure blinding. NICOM data, which has been well validated in septic patients, will be shared with the attending physician. They will then be asked if this new data will change management.

Study Overview

Status

Completed

Intervention / Treatment

Detailed Description

This is a diagnostic accuracy study comparing selected ultrasound techniques to a well validated standard for predicting fluid responsiveness in septic patients (NICOM). The primary outcomes will be reported in sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratios, and receiver operating characteristic curves.

The timeframe for measurement is within 72 hours of the subjects' admission. Determination of the outcome (i.e., whether a subject is fluid responsive) is based upon the data generated by the NICOM device. The NICOM generates data within 5 minutes of assessment. The ultrasound modalities to be studied will generate data within 5 minutes of assessment as well. The US data will be compared to the NICOM data to generate the statistics listed in this protocol. There is no further planned follow-up for the subjects.

  1. The investigators will compare the ability of dynamic changes in inferior vena caval diameter (IVC-CI), dynamic changes in peripheral arterial waveform derived variables (PA Doppler), and dynamic changes in left ventricular outflow tract waveform derived variables (LVOT Doppler) to detect fluid responsiveness (FRes) relative to FRes as assessed by bioreactance cardiac output monitoring before and after passive leg raise (PLR).

    Hypothesis: PA Doppler and LVOT Doppler will have superior sensitivity and specificity to predict FRes in comparison to IVC-CI.

  2. The investigators will evaluate data acquisition duration and data acquisition failure rate of IVC-CI, PA Doppler, and LVOT Doppler. Hypothesis: PA Doppler will have shorter data acquisition durations in comparison to LVOT velocity variation and IVC-CI.

    Hypothesis: PA Doppler will have lower data acquisition failure rates in comparison to LVOT velocity variation and IVC-CI.

  3. The investigators will compare the ability of IVC-CI, PA Doppler, and LVOT Doppler to predict FRes in comparison to FRes as predicted by clinical judgment.

    Hypothesis: PA Doppler and LVOT Doppler will have superior sensitivity and specificity to predict FRes in comparison to clinical judgment.

  4. The investigators will evaluate the ability of dynamic changes in PA corrected flow times (cFT) to detect FRes relative to FRes as assessed by bioreactance cardiac output monitoring before and after PLR. Hypothesis: cFT will have greatest sensitivity and specificity to predict FRes at a Δflow time threshold of ≥15% after PLR.

Hypothesis: At a Δflow time threshold of ≥15%, cFT will have superior sensitivity and specificity to detect FRes in comparison to IVC-CI.

Study Type

Observational

Enrollment (Actual)

50

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • California
      • Sylmar, California, United States, 91342
        • Olive View-UCLA

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 90 years (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

The investigators will recruit adult patients in the ED and ICU who are septic, have received an initial bolus of 20-30 cc/kg of IV fluid, and there is still a question by the clinical team of whether they are still fluid responsive.

Description

Inclusion Criteria:

  • Subjects presenting to the ED will be screened in accordance with the Olive View Medical Center Sepsis Waiver, and subjects meeting two of the following four criteria will be eligible for inclusion in the study: Temperature >38/100.4 or <36/96.8, heart rate >90, respiratory rate >20 or PaCO2<32, and WBC >12K or <4K or > 10% bands (neutrophils). The clinical team will be contacted regarding patients identified based on this initial screening, and if the patient is determined to have a suspected infection and a fluid bolus is planned, the patient will be enrolled in the study if they meet the following criteria:
  • Adult between the age of 18 to 90 years old;
  • Not pregnant;
  • Not using non-invasive positive pressure ventilation (CPAP or BiPAP);
  • No history of heart, lung, and/or liver transplant;
  • Not determined by the clinical team to be acutely unstable requiring immediate intervention at the time of data collection, and;
  • No contraindications to a passive leg raise test (known or suspected cranio-cerebral or C-spine injury, venous thrombosis, orthopedic injury requiring immobilization or traction, or other contraindications as per clinical team).

Exclusion Criteria:

  • Pregnant;
  • Using non-invasive positive pressure ventilation (CPAP or BiPAP);
  • Presence of or suspected elevated intracranial pressure;
  • Presence of central venous catheters or other medical devices that prevent the use of bedside ultrasound;
  • History of heart, lung, and/or liver transplant;
  • History of critical aortic stenosis or severe aortic insufficiency;
  • Determined by the clinical team to be acutely unstable and requiring immediate intervention at the time of study enrollment or data collection or;
  • Has a contraindication to passive leg raise maneuver, e.g. known cervical spinal injury, deep venous thrombosis, orthopedic injury requiring immobilization or traction.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Fluid responsiveness (measured as cardiac output change, velocity time integral change, or maximal velocity change of greater than 10%, with either passive leg raise maneuver or respiratory variability).
Time Frame: Fluid responsiveness is assessed in a three minute interval using the study gold standard, the NICOM. FRes assessment using ultrasound will be performed during this time. One set of measurements will be obtained upon subject admission to the ED or ICU.
FRes is defined as the ability to predict that subjects who receive a small bolus of 250-500 ml of intravenous fluid will have a rise in their cardiac output or stroke volume of greater than 10%. FRes is a unit-less measurement, as it reflects the percent change in either stroke volume, cardiac index/output, IVC diameter, VTI, or Vmax, as a result of either a passive leg raise or the respiratory cycle. The criterion standard for FRes in this study will be assessed with the NICOM machine. Assessments of FRes using ultrasound-based measures (LVOT, carotid, femoral, and IVC) will be compared to the NICOM-determined assessment of FRes. Analysis is directed at how well the ultrasound-based definitions of FRes perform compared to the NICOM-based assessment.
Fluid responsiveness is assessed in a three minute interval using the study gold standard, the NICOM. FRes assessment using ultrasound will be performed during this time. One set of measurements will be obtained upon subject admission to the ED or ICU.

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Alan Chiem, MD MPH, Olive View-UCA

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Helpful Links

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (ACTUAL)

November 1, 2014

Primary Completion (ACTUAL)

November 1, 2019

Study Completion (ACTUAL)

December 1, 2019

Study Registration Dates

First Submitted

November 26, 2014

First Submitted That Met QC Criteria

February 5, 2016

First Posted (ESTIMATE)

February 10, 2016

Study Record Updates

Last Update Posted (ACTUAL)

April 8, 2020

Last Update Submitted That Met QC Criteria

April 6, 2020

Last Verified

April 1, 2020

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • IRB #14H-136004

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.