Cemented Hemiarthroplasty Versus Uncemented Furlong Hemiarthroplasty

March 9, 2021 updated by: Martyn J Parker, Peterborough and Stamford Hospitals NHS Foundation Trust

Randomised Controlled Trial of Cemented Hemiarthroplasty Versus Uncemented Furlong Hemiarthroplasty

In England each year over 9,000 people fracture their hip. Most of these are elderly females with the fracture occurring after a fall. Approximately half of these fractures are classified as intracapsular fractures because of their close proximity to the hip joint. The majority of these fractures are treated surgically by excising the broken femoral neck and removing the femoral head (ball part of the hip joint) and replacing it with an artificial hip joint. This hip replacement has traditionally been a hemiarthroplasty or sometimes termed a 'half hip replacement' in which only the ball part of the hip joint is replaced.

There are a number of different designs of hemiarthroplasty that may be used. Some of the implants are fixed in place with bone cement whilst the rest are inserted as a press fit without the bone cement. The early designs of implant were all press fit but these designs have now been shown to be inferior to those implants that are fixed in place with bone cement.

There are however a number of newer designs of implant that are coated with a substance (hydroxyapatite) that encourage the bone to grow onto the implant to fix it into place. To date these implants have only been compared to the cement fit implants in only one previous study. This study found no notable difference between the two types of hemiarthroplasty. This study aims to add to the research studies by comparing standard cement fit implant with a hydroxyapatite coated press fit implant to assist in determining the optimum surgical treatment for this common and disabling condition.

Both implants to be used in this study are still being used extensively within the United Kingdom and worldwide to treat this fracture. The study is therefore using two different implants within their recommended area of use, but in which there is uncertainty as to which is the best implant.

Study Overview

Detailed Description

As a follow-on from our current randomised trials of different types of treatment for hip fractures, we wish to undertake a prospective randomised trial to compare a modern cemented hemiarthroplasty prosthesis with a modern hydroxyapatite coated uncemented arthroplasty.

Cemented Exeter monoblock hemiarthroplasty The Exeter stemmed total hip replacement is considered one of foremost performing hip replacements in the world. The ETS (Exeter trauma stem) is one such implant and costs around £200. The implant has modern instrumentation and the stem has proven long term survival rates when used for total hip replacement.

Hyroxyapatite coated prosthesis Coating a hip prosthesis with hydroxyapatite is common practice for an uncemented hip replacement arthroplasty. The hydroxyapatite stimulates bone ingrowth around the prosthesis and is this is thought to reduce loosening of the implant, residual pain and the long-term revision rate.

The aim of the study is to assist in defining the optimum choice of arthroplasty for an acute hip fracture.

Study Type

Interventional

Enrollment (Actual)

400

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Cambs
      • Peterborough, Cambs, United Kingdom, PE36DA
        • Peterborough and Stamford Hospital NHS Foundation Trust

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

16 years and older (Child, Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • All patients admitted to Peterborough City Hospital with a displaced intracapsular fracture will be considered for inclusion in the study.

Exclusion Criteria:

  • • Younger patients in which internal fixation is felt to be the choice of treatment to preserve the femoral head. This is generally those aged less than 60 years in which these patient have an expected good long term survival and are all treated by reduction and internal fixation.

    • All other patients in whom the injury is to be treated by reduction and internal fixation for a specific indication.
    • Those patients who are able to walk independently out of doors with no more than the use of a stick and are not cognitively impaired. These patients will first be considered for the ongoing randomised trial of Hemiarthroplasty or Total hip replacement (R&D reference - R&D/2012/30, REC reference - 12/LO/15490)
    • Patients who decline to participate.
    • Patients admitted when MJP is not available to supervise treatment.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Cemented monoblock hemiarthroplasty
The cemented monoblock hemiarthroplasty is a double tapered polished stem with a hemiarthroplasty head cemented in place (Zimmer incorporated, UK)
A cemented double tapered stem hemiarthroplasty
Experimental: Hyroxyapatite coated prosthesis
the Furlong Hyroxyapatite coated prosthesis (JRI orthopaedics limited UK) is a hydroxyapatite coating uncemented a hip prosthesis with a hemiarthroplasty head. The implant is uncemented.
A furlong uncemeneted hyroxyapatite coated prosthesis.The hydroxyapatite stimulates bone ingrowth around the prosthesis and is this is thought to reduce loosening of the implant, residual pain and the long-term revision rate.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
regain of mobility
Time Frame: assessed at one year from injury
measurement with a mobility score - Kristensen MT, Bandholm T, Foss NB, Ekdahl C, Kehlet H. High inter-tester reliability of the new mobility score in patients with hip fracture. J Rehabil Med 2008;40:589-91.
assessed at one year from injury

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

August 1, 2013

Primary Completion (Actual)

June 1, 2018

Study Completion (Actual)

July 1, 2019

Study Registration Dates

First Submitted

December 16, 2016

First Submitted That Met QC Criteria

December 16, 2016

First Posted (Estimate)

December 20, 2016

Study Record Updates

Last Update Posted (Actual)

March 11, 2021

Last Update Submitted That Met QC Criteria

March 9, 2021

Last Verified

April 1, 2018

More Information

Terms related to this study

Other Study ID Numbers

  • 13/WM/0049

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

No

IPD Plan Description

no IPD will be generated

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Hip Fractures

Clinical Trials on Cemented tapered stem hemiarthroplasty

Subscribe