- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT03249805
MiracleFeet Foot Abduction Brace Sensor Trial (mFAB)
Efficacy of a New Design of Foot Abduction Brace (FAB) Compared to Standard FAB During Ponseti Treatment of Idiopathic Clubfoot by Measuring Rate of Recurrence and Compliance Using Novel Touch Sensors
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Clubfoot is the most common birth defect affecting 1 in every 750 live births, that is about 200,000 babies each year globally (80% mainly in developing countries). An estimated average 1 million children are currently living with untreated clubfoot. In India every 10 minutes a child is born with clubfoot i.e. over 50,000 children are born with this deformity every year (1 per 500 birth). The Ponseti Method is now recognized as the accepted standard for the medical treatment of clubfoot. The Ponseti Method is ideally suited for the developing world in that it is inexpensive, non-surgical and the casting component can be completed by trained medical and paramedical personnel. Clubfoot causes the feet of the affected individual to point downward and inward. Left untreated, clubfoot causes a permanent physical disability, preventing the individual from walking normally and limiting his or her mobility. Decreased ambulation can lead to the inability to perform daily tasks, such as going to school, leading to increased dependency and a negative economic impact on the family. Furthermore, deformity caused by neglected clubfoot can lead to limited social integration and stigma for both the individual and the family.
The gold standard of clubfoot treatment is the Ponseti method, which consists of 6-8 weeks of serial castings followed by a percutaneous Tendo Achilles tenotomy in the majority of cases. The casting is followed by the use of a foot abduction brace (FAB) for approximately 4 years. The goal of the treatment is to correct the deformity so that the patient has a functional, painless, plantigrade foot with full mobility without the need for orthotics. The 6-8 weeks of serial casting corrects the clubfoot deformity while the use of the FAB after casting prevents the deformity from reoccurring and is required for successful treatment. Noncompliance of FAB use increases the risk of relapse 17-fold.
Currently, the Steenbeek Foot Abduction Brace (SFAB), a version of the Denis Browne splint, is the only low-cost FAB available. The SFAB is made by hand by artisans, limiting its large-scale production. Furthermore, it can be challenging to put on a child due to the shoes being attached to the bar and lacking a strap in addition to laces, potentially leading to noncompliance.
The more recently developed MiracleFeet Foot Abduction Brace (mFAB) is made of injection molded plastic, making it easy to mass produce, and includes removable shoes with a strap to hold the heel in place, claiming to be more comfortable and easier to use, leading to improved compliance.
The MiracleFeet Foot Abduction Brace (mFAB) is a Denis Browne Splint used for the treatment of clubfoot. Use of the Denis Browne Split is standard in clubfoot treatment and the mFAB complies with the standards for foot abduction braces for clubfoot:
- Adjustable to 65 and 45 degrees to accommodate unilateral and bilateral clubfoot
- 10 degrees dorsiflexion
The mFAB was designed with the following additional features, based on requests from parents and providers:
- Large window to view the heel, ensuring it lays flat in the shoe
- Dorsal strap to secure the heel, allowing the shoe to be tied with two hands
- Removable shoes so that the shoes may be applied and then clipped into the bar
- A flat bottom
- The bar is made of strong injection-modeled plastic, in order to be reused
- The shoes are meant to be worn only by 1 child and then discarded
The mFAB shoes are made of canvas and polyester and the bar and shoe plates are made of ortholite and T90 and are manufactured using the injected-molded plastic process in Batavia, Illinois, USA.
The mFAB has been tested in Nicaragua, Brazil, South Africa and the Philippines and is currently in use in 10 countries. Both braces meet the specifications as detailed by the Ponseti method and the same bracing protocol is used for both.
This study will compare treatment outcomes and compliance using the two brace designs, SFAB and mFAB. We will compare the number and time of recurrences, as well as the reported compliance and actual compliance, which will be measured by novel sensors. Few studies exist that compare brace types or actual versus reported compliance and FABs with sensors are a novel technology. Of the literature that exists, FAB use was show to decline significantly during the first 3 months and actual wear is less than reported wear.
Study Type
Enrollment (Anticipated)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Maharashtra
-
Mumbai, Maharashtra, India, 400012
- Recruiting
- Bai Jerbai Wadia Hospital for Children
-
Contact:
- Alaric Aroojis, MD
- Phone Number: +91 9320284402
- Email: aaroojis@gmail.com
-
Sub-Investigator:
- Rujuta Mehta, MD
-
Sub-Investigator:
- Avi Shah, MD
-
Sub-Investigator:
- Nelson Muthu, PhD
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Unilateral or bilateral cases of idiopathic clubfoot in children who have not yet started walking at first presentation, receiving a brace for the first time after successful correction with the Ponseti method of treatment, at the Bai Jerbai Wadia Hospital for Children over a period of 6 months.
Exclusion Criteria:
- All children who are already walking at presentation; All children with previous treatment; All children who have used FAB previously; All children treated with surgery other than tenotomy; All children with syndromic or neuropathic cases of clubfoot; All children with atypical clubfoot.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Steenbeek Foot Abduction Brace (SFAB)
The study will follow the subject for 6 months after their enrollment, beginning at first FAB use.
The Steenbeek Foot Abduction Brace (SFAB) is a fixed metal bar attached to two leather shoes with laces.
The shoes have laces and a strap.
The FABs provide 10 degrees of dorsiflexion and 45 or 65 degrees of abduction, and will be equipped with sensors to measure at-home FAB compliance.
After the last cast is removed, a brace will be worn for 23 hours/day for the first 3 months and the time will be gradually decreased thereafter to a 'nights and naps' protocol for a total of 12 hours/day.
At follow-up appointments the brace will be checked for fit and Pirani score recorded.
|
The FAB will be equipped with discretely hidden sensors; subjects and their families will not be aware of the actual function of the sensor in order to avoid increased compliance due to the sensor.
Sensors work on the principle of force-sensing resistor material whose resistance changes when a force or pressure is applied.
Force-sensing resistors consist of a conductive polymer, which changes resistance in a predictable manner following application of force to its surface.
On the top of braces sole we have fixed force resistive sensor (FSR), which changes resistance whenever force is applied.
Threshold of detection is 30-40 gram.
The changes of resistance is detected by using micro-controller.
Other Names:
|
|
Experimental: MiracleFeet Foot Abduction Brace (mFAB)
The study will follow the subject for 6 months after their enrollment, beginning at first FAB use.
The MiracleFeet Foot Abduction Brace (mFAB) is an injected plastic molded bar with fabric shoes that clip off and on.
The shoes have laces and a strap.
Both FABs provide 10 degrees of dorsiflexion and 45 or 65 degrees of abduction, and will be equipped with sensors to measure at-home FAB compliance.
After the last cast is removed, a brace will be worn for 23 hours/day for the first 3 months and the time will be gradually decreased thereafter to a 'nights and naps' protocol for a total of 12 hours/day.
At follow-up appointments the brace will be checked for fit and Pirani score recorded.
|
Sensors in the mFAB will measure whether the shoe is on, the foot is in contact with the sole of the shoe and the shoes are clipped into the bar.
Sensors work on the principle of force-sensing resistor material whose resistance changes when a force or pressure is applied.
Force-sensing resistors consist of a conductive polymer, which changes resistance in a predictable manner following application of force to its surface.
On the top of braces sole we have fixed force resistive sensor (FSR), which changes resistance whenever force is applied.
Threshold of detection is 30-40 gram.
The changes of resistance is detected by using micro-controller.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in Pirani Score
Time Frame: One year
|
The Pirani score is a standardized tool measuring that severity of clubfoot deformity.
It will be assessed at all visits - baseline, during treatment and follow-up - to evaluate gradual recurrence of clubfoot deformity.
|
One year
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Orthotics Prosthetics User Survey (OPUS) Results
Time Frame: One year
|
Parent satisfaction with the FABs will be determined by administering an OPUS to them at each follow-up visit.
|
One year
|
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Minutes of brace usage per day
Time Frame: One year
|
To measure at-home brace use compliance, the sensor data will be collected and compared to parent-reported brace usage.
This will be tabulated in number of minutes the brace is used per day, collected at each follow-up visit.
|
One year
|
Collaborators and Investigators
Sponsor
Collaborators
Investigators
- Principal Investigator: Alaric Aroojis, MD, Bai Jerbai Wadia Hospital for Children
Publications and helpful links
General Publications
- Ponseti IV. Treatment of congenital club foot. J Bone Joint Surg Am. 1992 Mar;74(3):448-54. No abstract available.
- Morcuende JA, Dolan LA, Dietz FR, Ponseti IV. Radical reduction in the rate of extensive corrective surgery for clubfoot using the Ponseti method. Pediatrics. 2004 Feb;113(2):376-80. doi: 10.1542/peds.113.2.376.
- Morgenstein A, Davis R, Talwalkar V, Iwinski H Jr, Walker J, Milbrandt TA. A randomized clinical trial comparing reported and measured wear rates in clubfoot bracing using a novel pressure sensor. J Pediatr Orthop. 2015 Mar;35(2):185-91. doi: 10.1097/BPO.0000000000000205.
- Zionts LE, Frost N, Kim R, Ebramzadeh E, Sangiorgio SN. Treatment of idiopathic clubfoot: experience with the Mitchell-Ponseti brace. J Pediatr Orthop. 2012 Oct-Nov;32(7):706-13. doi: 10.1097/BPO.0b013e3182694f4d.
- Boehm S, Sinclair M. Foot abduction brace in the Ponseti method for idiopathic clubfoot deformity: torsional deformities and compliance. J Pediatr Orthop. 2007 Sep;27(6):712-6. doi: 10.1097/BPO.0b013e3181425508.
- Chen RC, Gordon JE, Luhmann SJ, Schoenecker PL, Dobbs MB. A new dynamic foot abduction orthosis for clubfoot treatment. J Pediatr Orthop. 2007 Jul-Aug;27(5):522-8. doi: 10.1097/bpo.0b013e318070cc19.
- Garg S, Porter K. Improved bracing compliance in children with clubfeet using a dynamic orthosis. J Child Orthop. 2009 Aug;3(4):271-6. doi: 10.1007/s11832-009-0182-9. Epub 2009 Jun 3.
- Hemo Y, Segev E, Yavor A, Ovadia D, Wientroub S, Hayek S. The influence of brace type on the success rate of the Ponseti treatment protocol for idiopathic clubfoot. J Child Orthop. 2011 Apr;5(2):115-9. doi: 10.1007/s11832-010-0321-3. Epub 2010 Dec 24.
- Janicki JA, Wright JG, Weir S, Narayanan UG. A comparison of ankle foot orthoses with foot abduction orthoses to prevent recurrence following correction of idiopathic clubfoot by the Ponseti method. J Bone Joint Surg Br. 2011 May;93(5):700-4. doi: 10.1302/0301-620X.93B5.24883.
- Kessler JI. A new flexible brace used in the Ponseti treatment of talipes equinovarus. J Pediatr Orthop B. 2008 Sep;17(5):247-50. doi: 10.1097/BPB.0b013e32830cc3e5.
- Sangiorgio SN, Ho NC, Morgan RD, Ebramzadeh E, Zionts LE. The Objective Measurement of Brace-Use Adherence in the Treatment of Idiopathic Clubfoot. J Bone Joint Surg Am. 2016 Oct 5;98(19):1598-1605. doi: 10.2106/JBJS.16.00170.
- Thatipelli S, Arun A, Chung P, Etemadi M, Heller J, Kwiat D et al. Review of Existing Brace Adherence Monitoring Methods to Assess Adherence. Journal of Prosthetics and Orthotics. 2016;28(4):126-135.
- Manousaki E, Czuba T, Hagglund G, Mattsson L, Andriesse H. Evaluation of gait, relapse and compliance in clubfoot treatment with custom-made orthoses. Gait Posture. 2016 Oct;50:8-13. doi: 10.1016/j.gaitpost.2016.08.005. Epub 2016 Aug 7.
- Chong DY, Finberg NS, Conklin MJ, Doyle JS, Khoury JG, Gilbert SR. Prospective evaluation of the use of Mitchell shoes and dynamic abduction brace for idiopathic clubfeet. J Pediatr Orthop B. 2014 Nov;23(6):501-4. doi: 10.1097/BPB.0000000000000090.
- Thacker MM, Scher DM, Sala DA, van Bosse HJ, Feldman DS, Lehman WB. Use of the foot abduction orthosis following Ponseti casts: is it essential? J Pediatr Orthop. 2005 Mar-Apr;25(2):225-8. doi: 10.1097/01.bpo.0000150814.56790.f9.
- Ramirez N, Flynn JM, Fernandez S, Seda W, Macchiavelli RE. Orthosis noncompliance after the Ponseti method for the treatment of idiopathic clubfeet: a relevant problem that needs reevaluation. J Pediatr Orthop. 2011 Sep;31(6):710-5. doi: 10.1097/BPO.0b013e318221eaa1.
- Bouchoucha S, Smida M, Saied W, Safi H, Ammar C, Nessib MN, Ghachem MB. Early results of the Ponseti method using the Steenbek foot abduction brace: a prospective study of 95 feet. J Pediatr Orthop B. 2008 May;17(3):134-8. doi: 10.1097/BPB.0b013e3282fa5f0d.
- Desai L, Oprescu F, DiMeo A, Morcuende JA. Bracing in the treatment of children with clubfoot: past, present, and future. Iowa Orthop J. 2010;30:15-23.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Anticipated)
Study Completion (Anticipated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
- 0001 (Researcher)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Telemedicine
-
Michigan State UniversityUniversity of Michigan; Wake Forest University Health Sciences; Babes-Bolyai...CompletedUsual Care | Telemedicine: Smoking Cessation App Only | Telemedicine: Smoking Cessation Counseling | Telemedicine: App + CounselingRomania
-
Attune Health Research, Inc.Rheumatology Research FoundationRecruiting
-
University Hospital, Basel, SwitzerlandInnosuisse - Swiss Innovation AgencyCompleted
-
Wake Forest University Health SciencesCompleted
-
National University Health System, SingaporeCompletedTelemedicineSingapore
-
CochlearCompletedTelemedicineUnited States
-
The Hong Kong Polytechnic UniversityCompleted
-
Wake Forest University Health SciencesCompleted
-
Buzzi Children's HospitalCompleted
Clinical Trials on Steenbeek Foot Abduction Brace (SFAB)
-
Washington University School of MedicineShriners Hospitals for ChildrenCompletedIsolated ClubfootUnited States
-
Riphah International UniversityRecruiting
-
Milton S. Hershey Medical CenterWithdrawnRotator Cuff Tear | Rotator Cuff Tear ArthropathyUnited States
-
Queen Savang Vadhana Memorial Hospital, ThailandCompletedArthroscopic Rotator Cuff RepairThailand
-
Balgrist University HospitalCompletedRotator Cuff TearSwitzerland
-
The Hospital for Sick ChildrenCompleted
-
Odense University HospitalZealand University Hospital; Aarhus University Hospital; Sygehus LillebaeltNot yet recruitingPhysical Activity | Rehabilitation | Recovery | Ankle FractureDenmark
-
Odense University HospitalAarhus University Hospital; Hvidovre University Hospital; Bispebjerg Hospital; Herlev... and other collaboratorsRecruitingRehabilitation | Recovery | Ankle FractureDenmark, Faroe Islands
-
Cairo UniversityEnrolling by invitation
-
Eastern Mediterranean UniversityRecruiting