Short-term Implanted Electrodes Following Regenerative Peripheral Nerve Surgery for Improving Prosthetic Limb Control Signals
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
This is a single center, 10 subject early feasibility study in which the primary objective is to ensure the safety of percutaneous intramuscular electrodes implanted in surgically-created RPNI constructs in subjects with upper limb amputation. This will be assessed with endpoints measuring participant pain levels, RPNI graft tissue health, electrode migration, and unanticipated adverse events associated with medium-term electrode implantation. The secondary objectives are to assess the efficacy of the electrodes in recording electromyographic signals from the RPNI grafts and in delivering electrical stimulation to the RPNI grafts to evoke sensory percepts. These will be assessed with endpoints measuring the signal quality of the recorded signals and the stimulation thresholds required to evoke sensory percepts.
This study will enroll people who have had upper limb amputations or are planning to have upper limb amputations. Each participant who does not already have RPNI grafts at the time of enrollment will have RPNI grafts implanted on branches or fascicles of nerves of the upper extremity. Several or all RPNI grafts will have a single bipolar electrode implanted in the muscle tissue, with the proximal end tunneled to a percutaneous exit point on the residual limb. Additional electrodes may be placed in innervated muscles in the residual limb, in order to provide a control comparison as well as to provide additional input during prosthesis control experiments. Electrodes will remain implanted for up to 10 years, with a minimum of 2 study visits per month to perform prosthesis control and sensory feedback experiments. Study endpoint will be assessed at a minimum of once per month while electrodes remain implanted. After a maximum of 10 years, electrodes will be explanted and the study ended after a 1 week follow-up.
The results of this study will inform the final design of the electrodes to be implanted long-term in RPNI grafts to provide an increased number of degrees of freedom for prosthetic control and sensory and proprioceptive feedback. This will drastically improve the functionality of the prosthesis, enhance the sense of embodiment of the prosthesis itself, and enable future investigation of a fully-implanted (non-percutaneous) prosthesis control system.
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: Paul Cederna, M.D.
- Phone Number: 734-936-5885
- Email: cederna@umich.edu
Study Contact Backup
- Name: Karunakar Uppalapati, MS
- Phone Number: 517-356-3782
- Email: karunaka@med.umich.edu
Study Locations
-
-
Michigan
-
Ann Arbor, Michigan, United States, 48109
- Recruiting
- University of Michigan
-
Contact:
- Paul Cederna, M.D.
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Participants must be 22 years of age or older.
- Participants must have previously undergone an upper limb amputation proximal to the wrist or are scheduled to undergo an upper limb amputation proximal to the wrist.
- For participants without existing RPNI grafts (at the time of enrollment), the residual limb must have sufficient soft tissue quality to support performance of the RPNI operative procedure. Participants sustaining severe crushing or avulsion injuries with substantial superficial and deep scarring may not be appropriate candidates for inclusion in the study.
- Participants must be in good health and American Society of Anesthesiologists (ASA) Class I or II (low surgical risk).
- Participants must have reliable transportation.
- Participants must be able to attend at minimum 6 hours of experiments per month while electrodes remain implanted.
- Participants must be at least 6 months post-amputation.
- Participants who will receive an amputation at the same time as RPNI grafts and electrodes must be undergoing an elective amputation surgery where loss of useful function of the hand has occurred. They must be at least 6 months post-injury or failed limb salvage to participate.
Exclusion Criteria:
- Participants may not be suffering from any severe pain syndrome including complex regional pain syndrome or severe phantom pain. All of these conditions would suggest pathological activity of the nerve and would exclude the participant from participation.
- Participants must not be suffering from any untreated mental health disorders and if they have any DSM-5 diagnoses, they must receive approval to participate from their mental health professional.
- Participants must not have any medical conditions that, in the opinion of the Principal Investigator, would place them at high risk for a surgical procedure including recent myocardial infarction, cerebrovascular accidents, deep venous thrombosis, pulmonary embolus, uncontrolled diabetes, or end stage renal disease.
- Participants must not have used tobacco for at least one month prior to enrollment in the study.
- Participants must agree to not use tobacco for the duration of the study.
- Participants cannot have sustained bilateral upper extremity amputation.
- Participants cannot be pregnant.
- Participants must not have other indwelling electronic implants like pacemakers, implantable cardioverter defibrillators, implantable neurostimulators, body worn insulin pumps, or body worn patient monitoring devices.
- Participants must not have severe peripheral vascular occlusive disease, venous hypertension of the extremity, or severe lymphedema of the extremity.
- Participants must not have an autoimmune condition which is not well controlled by medication.
- Participants will not be considered for enrollment in Primary Upper Limb Amputation with RPNI Grafts and Electrode Implantation if their amputation is a traumatic injury or cancer related
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Device Feasibility
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: New Grafts
In this arm, participants will have an initial surgery to place partial muscle grafts on the amputated nerves.
After a healing period, the participant will have a shorter surgical procedure to implant the electrodes onto the muscle grafts and in residual muscles.
After another healing period, experiments with prosthetic control and sensory feedback will begin.
|
The device, a bipolar percutaneous intramuscular electromyography electrode, is intended for use in upper-limb amputation patients who have received the regenerative peripheral nerve interface surgical procedure, in order to enable the use of advanced prosthetic arms and hands.
|
|
Experimental: Existing Grafts
In this arm, participants have already had partial muscle grafts placed on the amputated nerves to control neuroma growth.
The participant will have a short surgical procedure to implant the electrodes onto the muscle grafts and in residual muscles.
After a healing period, experiments with prosthetic control and sensory feedback will begin.
|
The device, a bipolar percutaneous intramuscular electromyography electrode, is intended for use in upper-limb amputation patients who have received the regenerative peripheral nerve interface surgical procedure, in order to enable the use of advanced prosthetic arms and hands.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
RPNI tissue degeneration measured by pain scores
Time Frame: Baseline and once per month after surgery following a 3-month postoperative recovery period, while electrodes remain implanted.
|
RPNI tissue degeneration will be assessed by changes in pain scores (see above) and measurements of recording efficacy. Recording efficacy will be assessed using two signal quality measures:
|
Baseline and once per month after surgery following a 3-month postoperative recovery period, while electrodes remain implanted.
|
|
RPNI electrode migration assessed by changes recording in efficacy and ultrasound
Time Frame: Baseline and once per month after surgery following a 3-month postoperative recovery period, while electrodes remain implanted.
|
Electrode migration outside of the implanted RPNI graft or muscle will be assessed by changes in recording efficacy, as described above, and by ultrasound examination as necessary.
Electrode extrusion and implantation complications will be assessed by adverse events reported by both the participant and the study physicians.
At each study visit, the participant will be asked to report any issues, and will have a basic examination of the affected limb performed by study physicians and/or trained staff.
|
Baseline and once per month after surgery following a 3-month postoperative recovery period, while electrodes remain implanted.
|
|
Change in Pain Level as measured by SF-36
Time Frame: Baseline and monthly for up to 10 years postoperatively
|
Pain will be assessed using the SF-36 survey instrument, to be filled out by the participant before and after each surgical procedure performed and at a minimum of once per month while electrodes remain implanted.
Two questions related to pain with a score closer to 0 means a pain increase
|
Baseline and monthly for up to 10 years postoperatively
|
|
Change in Pain Level as measured by LANSS survey
Time Frame: Baseline and monthly for up to 10 years postoperatively
|
Pain will be assessed using the LANSS survey instrument, to be filled out by the participant before and after each surgical procedure performed and at a minimum of once per month while electrodes remain implanted.
A score greater than 12 indicates neuropathic pain.
|
Baseline and monthly for up to 10 years postoperatively
|
|
Change in Pain Level as measured by Phantom Limb Questionnaire
Time Frame: Baseline and monthly for up to 10 years postoperatively
|
Phantom pain will be assessed using the Phantom Limb Questionnaire, to be filled out by the participant before and after each surgical procedure performed and at a minimum of once per month while electrodes remain implanted.
This 9-item instrument measures phantom pain on a scale of 0-4, where 0-no pain at all and 4=very severe pain.
|
Baseline and monthly for up to 10 years postoperatively
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
EMG signal quality from RPNI grafts
Time Frame: Baseline and monthly for up to 10 years postoperatively
|
Efficacy will be assessed, for each implanted electrode using two calculated signal quality measures: Peak-to-peak signal amplitude during maximum voluntary contraction and signal-to-noise ratio during maximum voluntary contraction.
|
Baseline and monthly for up to 10 years postoperatively
|
|
Stimulation Threshold of RPNI grafts
Time Frame: Baseline and monthly for up to 10 years postoperatively
|
Stimulation data will be recorded at least once per month while electrodes remain implanted.
Stimulation threshold will be determined using the range of sensory feedback necessary to evoke a sensory percept.
|
Baseline and monthly for up to 10 years postoperatively
|
Collaborators and Investigators
Sponsor
Collaborators
Investigators
- Principal Investigator: Paul Cederna, M.D., University of Michigan
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- HUM00124839
- 5R01NS105132-05 (U.S. NIH Grant/Contract)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.