Efficacy of Closed-Loop Strategy With and Without a Learning Component in Children and Adolescents With Type 1 Diabetes at a Diabetes Camp

November 27, 2018 updated by: McGill University

An Open-Label, Randomized, Two-Way, Cross-Over Study to Compare the Efficacy of Closed-Loop Strategy With and Without a Learning Component in Children and Adolescents With Type 1 Diabetes at a Diabetes Camp

Our lab has developed an artificial pancreas system called the McGill Artificial Pancreas (MAP) for automating insulin delivery. Using patient's basal-bolus parameters (basal rates and ICRs), the artificial pancreas involves a control algorithm that modulates insulin infusion based on the sensor readings and meal information. However, because basal-bolus parameters are difficult to optimize, proper glycemic control is not always achieved. Therefore, we have developed a learning algorithm that estimates optimal basal-bolus parameters using data over several days. The algorithm examines daily glucose, insulin, and meal data to make changes in patients' basal rates and ICRs.

The objective of this project is to test our artificial pancreas system with and without the learning algorithm using a randomized crossover design in between 31 and 67 children and adolescents at camp Carowanis. We hypothesize that adding a learning algorithm to the artificial pancreas will improve the performance of our artificial pancreas system by increasing the time spent in target glucose range (4mmol/L - 10mmol/L) compared with the artificial pancreas system alone.

Study Overview

Status

Completed

Intervention / Treatment

Detailed Description

This is an open-label, randomized, two-way, cross-over study to compare the glucose control between closed-loop strategy with and without a learning module. Children and adolescent type 1 diabetes patients at Camp Carowanis will be enrolled in the study, where they will undergo two randomly ordered interventions:

  1. Closed-loop therapy: participants will undergo a closed-loop therapy where insulin delivery is determined by the MAP system. The study parameters (basal rates and ICRs) will be determined by the camp's physicians on day 1 of camp. The research staff will update the pump's settings to reflect the physician's recommendations at the beginning of the closed-loop therapy, and each time the physicians update the study parameters. Camp physicians will review participants' sensor and insulin data daily, and if necessary, adjust participant basal rates and ICRs. The research staff members will likewise adjust the pump's basal rates and ICR settings as per physician's recommendations. The closed-loop therapy will last 2 days (48 hours).
  2. Closed-loop therapy with learning module: participants will undergo a closed-loop therapy where insulin delivery is determined by the MAP system. The study parameters (basal rates and ICRs) will be computed by the learning algorithm and updated daily. The learning algorithm runs on a computer of the research staff members and requires patient data to calculate the optimal basal rates and ICR. Each morning, the research staff members will upload patient data onto the computer, run the leaning algorithm, and update the pump parameters to reflect the recommendations computed by the learning algorithm. Camp physicians will be to review the algorithm's recommendations before they are entered into the patient's pump. The closed-loop therapy with the learning module will last 8 days (192 hours).

Study Type

Interventional

Enrollment (Actual)

45

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Quebec
      • Sainte-Agathe-des-Monts, Quebec, Canada
        • Camp Carowanis

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

8 years to 21 years (ADULT, CHILD)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Males and females between 8 and 21 years old.
  2. Clinical diagnosis of type 1 diabetes for at least 12 months. The diagnosis of type 1 diabetes is based on the investigator's judgment; C peptide level and antibody determinations are not needed.
  3. The participant will have been on insulin pump therapy for at least 3 months.
  4. HbA1c ≤ 11%.

Exclusion Criteria:

  1. Participants who cannot or are unwilling to use NovoRapid (Aspart) insulin or Humalog (Lispro) insulin for the duration of the study.
  2. Serious medical illness likely to interfere with study participation or with the ability to complete the trial by the judgment of the investigator.
  3. Failure to comply with the study protocol or with team's recommendations (e.g. not willing to use trial pump, etc.).

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: TREATMENT
  • Allocation: RANDOMIZED
  • Interventional Model: CROSSOVER
  • Masking: SINGLE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
EXPERIMENTAL: Closed-loop therapy
Participants will undergo a closed-loop therapy where insulin delivery is determined by the MAP system. The study parameters (basal rates and ICRs) will be determined by the camp's physicians. The research staff will update the pump's settings to reflect the physician's recommendations at the beginning of the closed-loop therapy, and each time the physicians update the study parameters. The closed-loop therapy will last 2 days (48 hours).

The system is composed of 3 main components:

  1. Insulin infusion pump to infuse insulin. The pump model used in the study is t:slim, Tandem Diabetes Care.
  2. Continuous glucose monitor (CGM) to continuously measure glucose levels in the interstitial fluid. Glucose levels will be measured by Dexcom G5® CGM.
  3. MAP application (iMAP) that computes insulin infusion based on the glucose values. The application also alarms the user when glucose sensor values are approaching the hypoglycemic or hyperglycemic range. The iMAP runs on an android smartphone.

Every 10 minutes, iMAP retrieves the glucose values from the Dexcom G5 CGM via Bluetooth. The application computes an optimal insulin infusion rate based on i) the current glucose reading, ii) the glucose trend (i.e. how quickly the glucose level is rising or falling) and iii) the open-loop basal rates (study parameters). The insulin recommendations are then sent wirelessly via Bluetooth to the insulin pump.

EXPERIMENTAL: Closed-loop therapy with learning module
participants will undergo a closed-loop therapy where insulin delivery is determined by the MAP system. The study parameters (basal rates and ICRs) will be computed by the learning algorithm and updated daily. The learning algorithm runs on a computer of the research staff members and requires patient data to calculate the optimal basal rates and ICR. Each day, the research staff members will upload patient data onto the computer, run the leaning algorithm, and update the pump parameters to reflect the recommendations computed by the learning algorithm. The closed-loop therapy with the learning module will last 8 days (192 hours).

The system is composed of 3 main components:

  1. Insulin infusion pump to infuse insulin. The pump model used in the study is t:slim, Tandem Diabetes Care.
  2. Continuous glucose monitor (CGM) to continuously measure glucose levels in the interstitial fluid. Glucose levels will be measured by Dexcom G5® CGM.
  3. MAP application (iMAP) that computes insulin infusion based on the glucose values. The application also alarms the user when glucose sensor values are approaching the hypoglycemic or hyperglycemic range. The iMAP runs on an android smartphone.

Every 10 minutes, iMAP retrieves the glucose values from the Dexcom G5 CGM via Bluetooth. The application computes an optimal insulin infusion rate based on i) the current glucose reading, ii) the glucose trend (i.e. how quickly the glucose level is rising or falling) and iii) the open-loop basal rates (study parameters). The insulin recommendations are then sent wirelessly via Bluetooth to the insulin pump.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Percentage of time of sensor glucose levels spent in target range
Time Frame: 10-24hour periods
Target range defined to be between 3.9 mmol/L and 10.0 mmol/L
10-24hour periods

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Percentage of time of sensor glucose levels spent
Time Frame: 10-24hour periods
  1. between 3.9 and 7.8 mmol/L;
  2. between 3.9 and 10 mmol/L;
  3. below 3.9 mmol/L;
  4. below 3.3 mmol/L;
  5. below 2.8 mmol/L;
  6. above 7.8 mmol/L;
  7. above 10 mmol/L;
  8. above 13.9 mmol/L;
  9. above 16.7 mmol/L.
10-24hour periods
Percentage of overnight time (23:00-7:00) of sensor glucose levels
Time Frame: 10-24hour periods
  1. between 3.9 and 7.8 mmol/L;
  2. between 3.9 and 10 mmol/L;
  3. below 3.9 mmol/L;
  4. below 3.3 mmol/L;
  5. below 2.8 mmol/L;
  6. above 7.8 mmol/L;
  7. above 10 mmol/L;
  8. above 13.9 mmol/L;
  9. above 16.7 mmol/L.
10-24hour periods
Percentage of daytime (7:00-23:00) of sensor glucose levels
Time Frame: 10-24hour periods

Percentage of daytime (7:00-23:00) of sensor glucose levels

  1. between 3.9 and 7.8 mmol/L;
  2. between 3.9 and 10 mmol/L;
  3. below 3.9 mmol/L;
  4. below 3.3 mmol/L;
  5. below 2.8 mmol/L;
  6. above 7.8 mmol/L;
  7. above 10 mmol/L;
  8. above 13.9 mmol/L;
  9. above 16.7 mmol/L.
10-24hour periods
Standard deviation of glucose levels as a measure of glucose variability.
Time Frame: 10-24hour periods
10-24hour periods
Total insulin delivery.
Time Frame: 10-24hour periods
10-24hour periods
Mean sensor glucose level during: a. the overall study period; b. the daytime period; c. overnight period.
Time Frame: 10-24hour periods
10-24hour periods
Number of participants experiencing hypoglycemia requiring oral treatment during:
Time Frame: 10-24hour periods
10-24hour periods

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (ACTUAL)

July 2, 2018

Primary Completion (ACTUAL)

August 10, 2018

Study Completion (ACTUAL)

August 10, 2018

Study Registration Dates

First Submitted

June 27, 2018

First Submitted That Met QC Criteria

June 27, 2018

First Posted (ACTUAL)

July 10, 2018

Study Record Updates

Last Update Posted (ACTUAL)

November 29, 2018

Last Update Submitted That Met QC Criteria

November 27, 2018

Last Verified

November 1, 2018

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Diabetes

Clinical Trials on Artificial Pancreas

Subscribe