SLlt Stent II Lacrimal Stent for the Treatment of Nasolacrimal Duct Obstruction (SLINDO)
Safety and Efficacy of the Slit Stent II Lacrimal Stent for the Treatment of Nasolacrimal Duct Obstruction
This project aims to test whether a newly designed lacrimal stent - the SlitStent - when placed into the lacrimal system in the standard fashion following a DCR surgery, will provide good symptomatic relief for epiphora and be well tolerated.
Epiphora, or severe tearing, is both a very common debilitating symptom and a potential cause of dangerous infections (i.e. dacryocystitis and orbital cellulitis). DCR+lacrimal stenting surgery is 80-95% successful at improving epiphora, and the longer the stent remains in place, the better the long-term outcome. However, lacrimal stents that provide adequate circumferential force to facilitate post-DCR healing also occupy space and prevent good tear drainage until removed. Yet patients want complete symptomatic improvement as soon as possible, even if it compromises long-term results.
This study aims to test a newly designed lacrimal stent that allows tears to drain through the lumen of the stent. The new stent is constructed by modifying a commercially available stent by placing openings along the side of the stent using a process developed by a University of Michigan engineer/collaborator. Following slit placement, the stent will be gas-sterilized for surgery. Patient who are scheduled for DCR+stenting surgery who provide informed consent will be randomized 2:1 to receive the investigational SlitStent or the standard commercially available stent. Following surgery, patients will be assessed both clinically, which is standard of care, and via a patient questionnaire.
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
This is a single center study that will be conducted at the University of Michigan (Ann Arbor, Michigan). Fifty (50) subjects will be enrolled and treated with either the experimental Slit Stent II or the control stent BIKA for DCR. Patients who are currently scheduled to undergo a DCR (dacryocystorhinostomy) as per standard of care will be offered participation in the study. Patients who elect to participate in the study will be consented and then randomized to the treatment or control arm.
A lacrimal stent is hollow silicone tubing with a non-traumatic tip. The tubing is securely attached into malleable stainless steel probes that are used to guide the silicone tubing through the lacrimal drainage apparatus. The device is used to maintain an open lacrimal path between the surface of the eye and the nasal passages, particularly during a healing process following injury or surgery.
The BIKA for DCR lacrimal stent is a bicanalicular intubation device used for intubation of the lacrimal drainage apparatus, especially in cases of dacryocystorhinostomy (conventional or laser). The silicone tube acts as a conformer during the healing process while facilitating drainage of tears through capillary action around the stent. In cases of canalicular lacerations, the silicone tube guides wound healing and prevents the onset of synechia.
The BIKA lacrimal stent consists of a single unit including a silicone tube (length: 280 mm, external diameter: 0.94 mm), and one steel probe at each end of the silicone tube (length: 53 mm, external diameter: 0.8 mm) with round tips.
The BIKA for DCR is a sterile, single-use device, and is an FDA cleared device.
The Slit Stent II (investigational) device is created by modifying an existing FDA cleared lacrimal stent (Bika, manufactured by FCI Opthalmics) by adding additional 3 mm and 35 mm long slits of equal depth.
The axial cutouts located on the stent allow drainage of tears from the ocular surface to the nasal/oropharynx cavities through the internal lumen of the stent.
All modifications to the stent are inspected under an optical microscope at a magnification of at least 5x to ensure they are free from cutting defects, which could impact the structural integrity of the Slit Stent II. To ensure that the Slit Stent II can withstand the forces experienced during implantation and removal, additional mechanical integrity tests were performed. Comparing the implantation forces to the maximum insertion and removal force, it was determined that the modified Slit Stent II will have excellent tensile strength - essentially identical to unmodified stent - to prevent mechanical failure in patient use. Each section was tested to determine the maximum elongation and force it can withstand before failure.
The study duration will be 6 months for all study patients.
The following examination schedule will be followed from screening through the postoperative visits:
- Screening (Day -60 to Day 0 Preoperatively)
- Device implantation operation
- Phone call Assessment at 1 day post op
- Phone call Assessment at 45 days post op (+/- 15 days)
- Day 5-14 postoperatively
- Day 30-120 postoperatively (with stent removal)
- 4-7 month final post-operative exam
Subjects will be randomly assigned to the experimental vs. control stents using a randomized block design with 1:1 allocation to treatment and control. Stents will be provided to the surgical team on the day of surgery by the Study Coordinator. Surgical team, recruitment staff, and scheduling staff will be masked to treatment assignment until day of surgery. All tests and measurements should be obtained in accordance with the procedures specified in this protocol. If it is not possible to perform a measurement or examination due to the individual eye's specific ocular pathology, the reason for not performing the test or measurement should be documented on the source documents.
The investigator may designate one or more surgeon sub-investigators at his/her investigative site. A surgeon sub-investigator may evaluate subjects for the study and perform the Slit Stent II lacrimal stent intubation. Surgeon sub-investigators will be listed on all applicable investigator regulatory documents (including the delegation of responsibilities log) and will complete all sponsor-required training for the study.
For the two post-op study visits, the Quality of Life (QOL) questionnaire (Glasgow Benefit Inventory (GBI)- see Appendix A) and the Patient Tearing Questionnaire (Munk Scale and Lac-Q questionnaire, see Appendix B) will be administered by an interviewer, and the interviewer will record the subject's responses directly onto the corresponding questionnaire CRFs or source documents and calculate the GBI score, Munk Score, and Lac-Q score.
Study Type
Enrollment (Anticipated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: James Green, MHA
- Phone Number: 734-936-2929
- Email: greenjw@med.umich.edu
Study Contact Backup
- Name: Jeanne Wright, RAC
- Phone Number: 734-998-7598
- Email: jeanburn@med.umich.edu
Study Locations
-
-
Michigan
-
Ann Arbor, Michigan, United States, 48105
- Kellogg Eye Center, 1000 Wall Street
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Willingness and ability to comply with schedule for follow-up visits and postoperative evaluations.
- Eligible for unilateral DCR surgery with stenting for treatment of epiphora secondary to nasolacrimal duct obstruction.Ability to instill post-operative eye drop
- Signed written, informed consent.
Exclusion Criteria:
- Subjects under legal guardianship or who, in the investigator's opinion, lack the mental capacity to provide written informed consent for study participation.
- Subjects scheduled for bilateral DCR surgery
- Subjects with known sensitivity to silicone
- Subjects with a current condition that, in the investigator's opinion, would interfere with the treatment.
- Inability to use eye drops
- Subjects with a known sensitivity to required study medications (e.g. antibiotic drops) if an alternative medication is not available.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
---|---|
Experimental: Slit Stent II
The Slit Stent II (investigational) device is created by modifying an existing FDA cleared lacrimal stent (BIKA, manufactured by FCI Opthalmics) by adding additional 3 mm and 35 mm long slits of equal depth.
|
The Slit-Stent II device is created by modifying the BIKA for DCR lacrimal stent through the addition of a center slit, 12 ± 1.5 mm in length, and two lateral slits 32 ± 4.5 mm in length, each having identical depth measurements to facilitate the drainage of tears.
The BIKA for DCR is a sterile, single-use device that is FDA cleared as part of the BIKA family of devices under K911109..There are no changes to the raw materials used in making the modifications to the BIKA for DCR during the manufacturing of the Slit Stent II.
Other Names:
|
Active Comparator: BIKA for DCR
The BIKA for DCR is a sterile, single-use device, and is an FDA cleared device.
|
The BIKA for DCR lacrimal stent is a bicanalicular intubation device used for intubation of the lacrimal drainage apparatus, especially in cases of dacryocystorhinostomy (conventional or laser).
The silicone tube acts as a conformer during the healing process while facilitating drainage of tears through capillary action around the stent.
In cases of canalicular lacerations, the silicone tube guides wound healing and prevents the onset of synechia.
The BIKA for DCR is a sterile, single-use device, and is an FDA cleared device
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Safety, as measured by number of subjects with at least one Adverse Event
Time Frame: Surgery to final exit visit (Month 4-7)
|
Adverse events will be recorded from the time of surgical implantation of the device until the final visit.
Ophthalmic complications or adverse events that are observed by the investigator or reported by the subject will be recorded on the CRFs.
For all adverse effects, sufficient information will be pursued and/or obtained so as to permit 1) an adequate determination of the outcome of the effect (i.e., whether the effect should be classified as a serious adverse effect) and; 2) an assessment of the causal relationship between the adverse effect and the investigational device or, if applicable, the other study treatment or diagnostic product(s).
|
Surgery to final exit visit (Month 4-7)
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Glasgow Benefit Inventory (GBI) Questionnaire (Quality of Life)
Time Frame: 1-4 month post-operative follow-up visit
|
The effectiveness parameter evaluated will be the mean composite score for the GBI administered post-treatment at the 1-4 month post-operative follow-up visit.
scores can range from -100 to 100 where -100 represents decline in symptoms or function and 100 represents greatest improvement.
|
1-4 month post-operative follow-up visit
|
Lac-Q score
Time Frame: 1-4 months post operative
|
The Lac-Q questionnaire, published in 2011, is a patient symptom questionnaire developed for lacrimal drainage surgery.1-2
The questionnaire contains two scores, one is specific for eye-symptoms, and the other assesses the social impact of symptoms.
The scores are combined for a single Lac-Q score, whose lowest possible score can be 0 and highest 23, where 0 represents no problems related to watery eyes and 23 represents most symptoms and social challenge from them.
|
1-4 months post operative
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Thomas Gardner, MD, MS, University of Michigan Kellogg Eye Center
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Anticipated)
Study Completion (Anticipated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- HUM00114919
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Epiphora
-
Istanbul UniversityCompletedFunctional Epiphora (Tearing Without Any Anatomical Block)Canada, Turkey
-
Tianjin Medical University Cancer Institute and...RecruitingEpiphora Due to Insufficient Drainage, Left Side | Epiphora Due to Insufficient Drainage, Right SideChina
-
Tanta UniversityCompleted
-
Merbs, Shannath, M.D., Ph.D.CompletedEpiphoraUnited States
-
AurolabCompleted
-
Universitaire Ziekenhuizen KU LeuvenCompleted
-
Sinopsys SurgicalCompleted
-
Louisiana State University Health Sciences Center...RecruitingEpiphora | Dacryostenosis | DacryocystitisUnited States
-
Menoufia UniversityActive, not recruitingEpiphora | Dacryocystitis | DacryocystoceleEgypt
-
Minia UniversityCompleted
Clinical Trials on Slit Stent II
-
University of Wisconsin, MadisonNational Center for Complementary and Integrative Health (NCCIH)Completed
-
ASST Fatebenefratelli SaccoALK-Abelló A/SCompleted
-
University of North Carolina, Chapel HillNational Center for Complementary and Integrative Health (NCCIH)CompletedFood Hypersensitivity | Peanut Hypersensitivity | Peanut Allergy | Food AllergyUnited States
-
Assiut UniversityUnknown
-
Cairo UniversityCompletedPrimary Antiphospholipid SyndromeEgypt
-
University Hospital, Clermont-FerrandCompletedKeratoconus | Alteration of Visual AcuityFrance
-
Eyoto Group LtdCompleted
-
University of Texas Southwestern Medical CenterDallas VA Research CorporationWithdrawn
-
Sun Yat-sen UniversityNot yet recruitingArtificial Intelligence | Catarct ScreeningChina