One Minute Heart Rate Variability Quantification in Airway Obstruction Model (RRV Airway)

November 6, 2018 updated by: Dr. Amit Lehavi MD FANZCA, Rambam Health Care Campus
40 healthy volunteers underwent a trial of obstructed breathing through an eighteen cm long, four mm internal diameter tube. Heart rate was recorded during three consecutive sets comprised of one minute control followed by one minute of obstructed breathing, with one minute of rest between sets. Time and frequency domain analysis were used to compare HRV during control versus obstructed breathing.

Study Overview

Status

Completed

Conditions

Detailed Description

Following approval by the Institutional Review Board, the study was performed in a prospective cross-over, longitudinal cohort manner. Healthy volunteers aged between 20 and 40 years were included. Each participant signed an informed consent. Exclusion criteria were respiratory or cardiac pathology, diabetes, a body mass index lower than 18 or higher than 26 kg/m2, chronic medical conditions with significant involvement of the sympathetic or parasympathetic systems (e.g. diabetes), obstructive sleep apnea, use of medications with either cardiovascular or respiratory effects, and ECG abnormalities including heart rate other than sinus rhythm, atrioventricular conduction blocks, intrafascicular conduction delays or prolonged QT interval (the time between consecutive Q and T waves on the electrocardiogram).

Initially, each volunteer underwent an ultrasound evaluation (SonoSite™ M-Turbo™ ultrasound machine, SonoSite, Bothell, Washington, USA) of the lungs using a high frequency linear probe at mid clavicular lines to exclude pneumothorax, an apical view of the heart using a curve-linear probe to exclude pericardial effusion. A twelve lead ECG was obtained and analyzed to exclude rate or conduction abnormalities. Noninvasive blood pressure and oxygen saturation were recorded in all subjects throughout the study to identify and prevent any complication.

A three lead ECG and spirometry were obtained in supine position with the upper body raised by 30 degrees. Data was collected using a Datex AS/3 monitor (Datex Ohmeda Medical Equipment, GE Healthcare, USA). The data was recorded using a digital to analog acquisition card (NI-6008, National Instruments™, Austin, Texas, USA) and a Biosignal Logger of National Instruments™ Biomedical Workbench™ at a sampling rate of 500 Hertz (Hz). All experiments were performed at the same time of day (early afternoon), and under the same conditions (same place and experimental setup). Volunteers were instructed to refrain from smoking for 4 hours prior to participating in the study.

The airway obstruction was simulated by an 18 cm long, 4 mm internal diameter endotracheal tube, connected to a spirometry adaptor and an antimicrobial filter. During the obstructed breathing phase, the volunteers were directed to seal their lips tightly around the filter to prevent air leak and encouraged to reach a peak pressure of 30-40 cm H2O, using the instantaneous display on the spirometry monitor. Three sets were recorded for each volunteer; each set was comprised of one minute of normal unobstructed breathing that served as control, immediately followed by one minute of obstructed breathing. Following each set, the volunteers were allowed at least one minute of rest period to recover and return to their baseline breathing before the next set.

HRV analysis A detailed description of the means to measure and evaluate the significance of HRV can be found in the European Society of Cardiology and the North American Society of Pacing Electrophysiology Task Force on heart rate variability, standards of measurement and physiological interpretation and clinical use guidelines14. Briefly, the raw ECG signal was preprocessed (including high pass filtering to remove Baseline wandering and ECG feature identification) and the R-R intervals were extracted from the raw ECG signal using ECG Features Extractor of National Instruments™ Biomedical Workbench™ with threshold adjust factor of 0.1, a rough highest heart rate of 60 beats per minute, QRS frequency of 10-25 Hz and middle QRS onset and offset.

Evaluation of HRV is predominantly performed using time and frequency domains. It may be also performed using nonlinear methods; however, here the investigators concentrated on the more commonly used time and frequency domain methods. Time domain measures are based on the statistical analysis of the time interval between two adjacent QRS waves on the electrocardiogram complexes, referred to as R-R intervals (time between two consecutive R waves on the electrocardiogram). R-R intervals standard deviation (SD), root mean square of successive differences (RMSSD) between adjacent R-R intervals, number of pairs of successive R-R intervals that differ by more than 50 millisecond (NN50) and proportion of NN50 divided by total number of R-R intervals (pNN50) are routinely used to quantify HRV. Frequency domain employ mathematical manipulation to the signal, such as the fast Fourier transform (FFT), which converts the time function into a sum of sine waves of different frequencies. These are used to calculate the power spectral density in very low (VLF), low (LF) and high frequency (HF) ranges and provide a quantification of the physiological HRV-related effects. In this report the investigators did not include the VLF, as this value cannot be reliably measured with a brief measurement window of one minute. As HRV is clearly related to the heart rate, the investigators normalized the HF power and LF power to the heart rate15. The normalized values are referred to as HFnorm and LFnorm.

HRV parameters were calculated over one minute sampling window using the Heart Rate Variability Analyzer of National Instruments™ Biomedical Workbench™. Fast Fourier analysis was employed using a Hanning Window of 1024 samples with a 50% overlap, and with a 2 Hz interpolation rate and 1024 frequency bins. As suggested in the literature for the power spectral density calculation, HF was defined as 0.15-0.4 Hz, LF as 0.04-0.15 Hz and VLF as below 0.04 Hz14.

Respiratory rate calculation To evaluate the changes in respiration during the obstructed breathing the investigators calculated the respiratory rate during the control and obstructed breathing periods. the investigators used the raw ECG traces to calculate the respiratory rate16. This was done primarily based on the R wave amplitude, and calculating the number of local peaks in the sampling window. To obtain meaningful results the investigators chose the control and the obstructed breathing segments with the most obvious changes in the R wave amplitude. Using this methodology the investigators could reliably evaluate the respiratory rate in 33 subjects.

Study Type

Interventional

Enrollment (Actual)

40

Phase

  • Not Applicable

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 30 years (Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • 18 30 years old
  • healthy

Exclusion Criteria:

  • heart disease
  • lung disease
  • BMI > 26
  • ECG abnormalities

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Basic Science
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Healthy volunteers
Heart rate variability analysis extracted from ECG during normal and obstructed breathing

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Low Frequency Power Spectral Density
Time Frame: 1 minute
FFT HRV Low Frequency Power Spectral Density
1 minute

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

May 20, 2015

Primary Completion (Actual)

June 11, 2015

Study Completion (Actual)

July 1, 2015

Study Registration Dates

First Submitted

November 4, 2018

First Submitted That Met QC Criteria

November 5, 2018

First Posted (Actual)

November 7, 2018

Study Record Updates

Last Update Posted (Actual)

November 8, 2018

Last Update Submitted That Met QC Criteria

November 6, 2018

Last Verified

November 1, 2018

More Information

Terms related to this study

Other Study ID Numbers

  • RRV Airway

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

No

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Airway Obstruction

Clinical Trials on Heart rate variability analysis

3
Subscribe