The Left Bundle Cardiac Resynchronization Therapy Trial
A Non-inferiority Randomized Comparison Between LEFT BUNDLE Branch Area Pacing and Biventricular Pacing for Cardiac Resynchronization Therapy: The LEFT-BUNDLE-CRT Trial
Study Overview
Status
Intervention / Treatment
Detailed Description
Medical device: Only CE-marked CRT-P or CRT-D Medtronic devices locally approved and commercially available (Medtronic 3830 Pacing Lead) shall be used in this protocol.
Indication: Pacing and sensing in the right atrium or ventricle. It is also designed for pacing and sensing in the bundle as an alternative to pacing in the right ventricle in a single or dual chamber pacing system.
Intended use: Patients with an indication for cardiac resynchronization therapy.
Duration of the study: Approximate inclusion period of 18 months
Follow-up: Patients will be followed for 12 months ± 4 weeks after implant
Planned study period: The study is planned to start in Q1 2022
No. of sites: Approximately 11 sites in Spain.
No. of subjects: 176 patients will be enrolled in the study
Study type: Post-market study
Study rationale: Previous studies show 85% implantation success, significant reduction in QRS duration, and significant improvement in NYHA functional class, LVEF, and LV end-diastolic diameter. Left bundle branch pacing could be an alternative to conventional biventricular pacing.
Study design: Multicenter, prospective, randomized, non-inferiority, open.
Objectives of the study:
- Primary objective: The primary objective of the study is to demonstrate that LBBAP is associated with a non-inferior percentage of CRT responders at 6 months follow-up than conventional BiV pacing using a conventional CS lead in patients with CRT indications according to current guidelines. Positive CRT response will be defined either by an improved Clinical Composite Score or ≥15% reduction in left ventricular end-systolic volume at 6 months follow-up
- Secondary objectives: To evaluate reverse ventricular remodeling response and dyssynchrony parameters based on echocardiographic data at 6 and 12 months follow-up. To asess clinical outcome using the Clinical Composite Score, 6 minute walking test, quality of life measurements (EuroQuol EQ 5-D) at 6 and 12 months follow-up. To evaluate HF related hospitalizations at 6 and 12 months follow-up. To evaluate mortality (global and cardiovascular) and need for cardiac transplantation at 6 and 12 month follow-up. To evaluate incidence of ventricular arrhythmias at 6 and 12 month follow-up. To evaluate differences in CRT response depending on the final LBBAP modality (LBBP vs deep septal pacing). To evaluate device related complications at 6 and 12 month follow-up.
Primary Outcome Measures: Improved Clinical Composite Score or ≥15% reduction in left ventricular end-systolic volume at 6 months follow-up.
Participating sites:
- Hospital Universitario y Politécnico La Fe, Valencia
- Hospital Clinic de Barcelona
- Hospital Virgen de las Nieves, Granada
- Hospital Virgen de la Arrixaca, Murcia
- Hospital Puerta de Hierro, Madrid
- Hospital General de Alicante
- Hospital Bellvitge, Barcelona
- Hospital 12 de Octubre, Madrid
- Hospital Universitario Lozano Blesa, Zaragoza
- Hospital Juan Ramón Jiménez, Huelva
- Hospital Universitario San Cecilio, Granada
Study population: Subjects 18 years of age or older will be included in the study. Both sexes are eligible to participate. Subjects must present a left bundle branch block (according to Strauss criteria) with indication of CRT class I or IIa according to clinical practice guidelines. A selection of the subjects will be made before inclusion following the selection clinical investigation plan. After confirming that the subject meets the inclusion criteria and does not meet the exclusion criteria, they will be included in the clinical study.
Study population criteria:
- Inclusion criteria: age > 18 years; Class I or IIa indication for CRT according to current ESC or ACC/AHA/HRS guidelines; left bundle branch block according to Strauss criteria; Signed and dated informed consent.
- Exclusion criteria: Pregnant woman; Permanent or long-lasting atrial fibrillation; Previous CRT device; Previous PM/ICD with ventricular pacing > 10%; Conventional pacemaker indication; Nonspecific IVCD (intraventricular conduction delay); Unstable angina, acute Myocardial Infarction (MI), Coronary Artery Bypass Graft (CABG), Percutaneous Coronary Angioplasty (PCI), valve repair or replacement within 90 days prior enrollment; Indication for valve repair or replacement; Already included in another clinical study that could confoud the results of the present study; Life expectancy < 12 months.
Device Implantation Procedure: CRT obtained by biventricular pacing vs. CRT obtained by stimulating the left branch area.
Follow-up: Follow-up should be carried out with pre-established periodic clinical appointments 3, 6, and 12 months after hospital discharge. In the follow-up, routine examinations such as vital signs, electrocardiogram and echocardiogram (6 and 12 months) are recorded to check the evaluation of the reverse ventricular remodeling response and asynchrony parameters based on echocardiographic data.
Statistical considerations: Once patients have signed the informed consent at baseline visit, patients will be considered as "Enrolled population" in the statistical analysis. The sample size is based on the primary endpoint: Improved Clinical Composite Score or ≥15% reduction in left ventricular end-systolic volume at 6 months follow-up, showing that LBBAP is non-inferior to BiV-CRT. Accounting for a global attrition rate of 10% and considering the block size for randomization, 176 patients shall be enrolled.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Alicante, Spain
- Hospital General Universitario de Alicante Doctor Balmis
-
Granada, Spain, 18014
- Hospital Universitario Virgen de las Nieves
-
Granada, Spain, 18016
- Hospital Universitario San Cecilio
-
Huelva, Spain, 21005
- Hospital Universitario Juan Ramón Jiménez
-
Madrid, Spain, 28041
- Hospital 12 Octubre
-
Murcia, Spain
- Hospital Universitario Virgen de la Arrixaca
-
Valencia, Spain, 46026
- Hospital Universitari i Politècnic La Fe
-
Zaragoza, Spain, 50009
- Hospital Clínico Universitario Lozano Blesa
-
-
Barcelona
-
Hospitalet de Llobregat, Barcelona, Spain, 08907
- Hospital Universitario de Bellvitge
-
-
Madrid
-
Majadahonda, Madrid, Spain, 28222
- Hospital Universitario Puerta de Hierro
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- age > 18 years
- Class I or IIa indication for CRT according to current ESC or ACC/AHA/HRS guidelines
- left bundle branch block according to Strauss criteria
- Signed and dated informed consent
Exclusion Criteria:
- Pregnant woman
- Permanent or long-lasting atrial fibrillation
- Previous CRT device
- Previous PM/ICD with ventricular pacing > 10%
- Conventional pacemaker indication
- Nonspecific IVCD (intraventricular conduction delay)
- Unstable angina, acute Myocardial Infarction (MI), Coronary Artery Bypass Graft (CABG), Percutaneous Coronary Angioplasty (PCI), valve repair or replacement within 90 days prior enrollment
- Indication for valve repair or replacement
- Already included in another clinical study that could confoud the results of the present study
- Life expectancy < 12 months
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Cardiac resynchronization therapy (CRT) obtained by stimulating the left branch area
The CRT-P/CRT-D device and leads should be implanted according to the physician's standard practice. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. It is strongly encouraged the designation of a single and experienced implanting physician at each center for the LBBAP implant procedures. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). For LBBAP, the Medtronic 3830 lead will be used. Acceptable LBBAP threshold should be <2,5V@0,5ms. |
Standard BiV-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's manual provided with the devices. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. The LV lead should be implanted at a lateral or posterolateral CS branch in a basal or mid ventricular position confirmed by ortogonal fluoroscopic views (RAO and LAO 40º). Acceptable LV pacing threshold should be <3V@0,5ms and phrenic nerve stimulation (PNS) margin should be >1V with respect to the pacing threshold. LBBAP-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's standard practice. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). For LBBAP, the Medtronic 3830 lead will be used. Acceptable LBBAP threshold should be <2,5V@0,5ms |
|
Active Comparator: Cardiac resynchronization therapy (CRT) obtained by biventricular pacing
The CRT-P/CRT-D device and leads should be implanted according to the physician's manual provided with the devices. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. Investigators may use any market approved right atrial (RA) pace/sense lead, right ventricular (RV) pacing/defibrillator lead with pace/sense capabilities and any market approved unipolar/bipolar/quadripolar LV pacing lead. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). The LV lead should be implanted at a lateral or posterolateral CS branch in a basal or mid ventricular position confirmed by ortogonal fluoroscopic views (RAO and LAO 40º). Acceptable LV pacing threshold should be <3V@0,5ms and phrenic nerve stimulation (PNS) margin should be >1V with respect to the pacing threshold |
Standard BiV-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's manual provided with the devices. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. The LV lead should be implanted at a lateral or posterolateral CS branch in a basal or mid ventricular position confirmed by ortogonal fluoroscopic views (RAO and LAO 40º). Acceptable LV pacing threshold should be <3V@0,5ms and phrenic nerve stimulation (PNS) margin should be >1V with respect to the pacing threshold. LBBAP-CRT The CRT-P/CRT-D device and leads should be implanted according to the physician's standard practice. Only locally approved Medtronic CRT-P/CRT-D generators will be used during the study. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). For LBBAP, the Medtronic 3830 lead will be used. Acceptable LBBAP threshold should be <2,5V@0,5ms |
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
CRT response
Time Frame: 6 months follow-up
|
Positive CRT response will be defined either by an improved Clinical Composite Score or ≥15% reduction in left ventricular end-systolic volume
|
6 months follow-up
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Left ventricular ejection fraction
Time Frame: 6 and 12 months follow-up
|
To evaluate left ventricular ejection fraction at 6 and 12 months follow-up
|
6 and 12 months follow-up
|
|
Clinical outcome
Time Frame: 6 and 12 months follow-up
|
Assessed by the Clinical Composite Score
|
6 and 12 months follow-up
|
|
Exercise capacity
Time Frame: 6 and 12 months follow-up
|
Assessed by 6 minute walking test
|
6 and 12 months follow-up
|
|
Heart Failure Hospitalizations
Time Frame: 6 and 12 months follow-up
|
Assessment of heart failure hospitalizations
|
6 and 12 months follow-up
|
|
Mortality
Time Frame: 6 and 12 months follow-up
|
To evaluate mortality (global and cardiovascular)
|
6 and 12 months follow-up
|
|
Cardiac transplantation
Time Frame: 6 and 12 months follow-up
|
To evaluate the need for cardiac transplantation during follow-up
|
6 and 12 months follow-up
|
|
Ventricular arrhythmias
Time Frame: 6 and 12 month follow-up
|
To evaluate incidence of ventricular arrhythmias (clinical and registered by the ICD/PM)
|
6 and 12 month follow-up
|
|
Device related complications
Time Frame: 6 and 12 month follow-up
|
Device related complications needing re-intervention
|
6 and 12 month follow-up
|
|
The EQ-5D three-level version (EQ-5D-3L)
Time Frame: 6 and 12 months follow-up
|
Is a generic measure of health status consisting of 2 parts.
The first assesses health in five dimensions (mobility, selfcare, usual activities, pain / discomfort, anxiety / depression), each of which has 3 levels of response (no problems, some problems, extreme problems / unable to).
This part of the questionnaire provides a descriptive profile that can be used to generate a health state profile.
Each health state can potentially be assigned a summary index score based on societal preference weights for the health state.
Health state index scores generally range from less than 0 (where 0 is a health state equivalent to death; negative values are valued as worse than death) to 1 (perfect health), with higher scores indicating higher health utility.
The second part consists of a VAS on which the patient rates his / her perceived health from 0 (the worst imaginable health) to 100 (the best imaginable health)
|
6 and 12 months follow-up
|
Collaborators and Investigators
Sponsor
Collaborators
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- LB-CRT-001
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Heart Failure
-
Indiana UniversityRecruitingCongestive Heart Failure | Congestive Heart Failure (CHF) | Congestive Heart Failure Chronic | Congestive Heart Failure(CHF)United States
-
University of Health Sciences LahoreRecruitingAcute Decompensated Heart Failure | Heart Failure, Diastolic | Heart Failure, SystolicPakistan
-
Tufts Medical CenterMetro West Medical CenterCompletedCongestive Heart Failure | Diastolic Heart Failure | Systolic Heart FailureUnited States
-
Abbott Medical DevicesCompletedHeart Failure | Heart Failure, Diastolic | Heart Failure, Systolic | Heart Failure NYHA Class II | Heart Failure NYHA Class III | Heart Failure With Reduced Ejection Fraction | Heart Failure NYHA Class IV | Heart Failure With Normal Ejection Fraction | Heart Failure; With Decompensation | Heart Failure...United States, Canada
-
Manipal UniversityUnknownHeart Failure | Decompensated Heart Failure | Acute Heart Failure | Diastolic Heart Failure | Systolic Heart FailureIndia
-
Lakeland Regional Health Systems, Inc.RecruitingHeart Failure | Heart Failure Acute | Acute Heart Failure (AHF) | Heart Failure - NYHA II - IVUnited States
-
VA Eastern Colorado Health Care SystemNational Institute on Aging (NIA)CompletedHeart Failure | Heart Failure, Diastolic | Heart Failure, Systolic | Heart Failure With Reduced Ejection Fraction | Heart Failure With Preserved Ejection Fraction | Heart Failure; With Decompensation | Heart Failure,Congestive | Heart Failure AcuteUnited States
-
Wake Forest UniversityCompletedHeart Failure, Congestive | Heart Failure With Preserved Ejection Fraction
-
Eli Lilly and CompanyNot yet recruitingHeart Failure | Heart Failure, Diastolic | Heart Failure, SystolicUnited States, Japan
-
Wake Forest UniversityNational Institute on Aging (NIA)CompletedHeart Failure, Congestive | Diastolic Heart FailureUnited States
Clinical Trials on Cardiac resynchronization therapy
-
Universitaire Ziekenhuizen KU LeuvenActive, not recruitingHeart Failure | Cardiomyopathy, Dilated | Left Ventricular Dyssynchrony | Cardiac Remodeling, VentricularBelgium, Germany, Poland, France, Switzerland, Brazil, Spain, Hungary, Latvia, Portugal, Romania
-
Larisa TereshchenkoCompletedHeart Failure | Cardiomyopathy | Left Bundle Branch BlockUnited States
-
Biotronik SE & Co. KGActive, not recruitingHeart FailureFrance, Spain, Belgium, Israel, United Kingdom, Australia, Japan, Latvia, Germany, Singapore, Italy, Switzerland, Portugal, Czechia, Taiwan, South Africa, Austria, Hungary, Slovakia, Poland
-
University Medical Center GroningenNot yet recruitingHeart Failure | Atrial Fibrillation (AF) | Cardiac PacingGermany, France, Netherlands, Italy
-
Paris Cardiovascular Research Center (Inserm U970)University Hospital, Montpellier; Groupe Hospitalier Pitie-Salpetriere; European... and other collaboratorsCompletedCongenital Heart Disease
-
Maastricht University Medical CenterMedtronicUnknownCardiac Resynchronization Therapy, Non-LBBB, QRS AreaNetherlands
-
University of LouisvilleWithdrawn
-
Medtronic Latin AmericaUnknown