Temperature Profiles During Laser Activation in Ureteroscopic Lithotripsy
Temperature Profiles During Laser Activation in Ureteroscopic Lithotripsy - a Prospective Clinical Study
The primary aim of this study is to investigate the temperature profiles in the renal pelvis during ureteroscopic Thulium Fiber Laser activation using different settings. To this end, comparison of peak temperatures during laser activation for different settings is the main aim. Secondary aim is trying to define the duration of safe laser activation until the threshold for heat induced cell injury (43oC) is reach.
Patients ≥ 18 years with a ureteral stone (with or without a concomitant renal stone) and an indwelling nephrostomy tube scheduled for ureteroscopic lithotripsy at the day surgery unit at Haukeland University Hospital, are eligible to enrolment in the study.
Temperature measurements during ureteroscopic laser stone disintegration will be performed. Follow-up is standardised with clinical consultation and low dose CT 3 months post endoscopically.
Study Overview
Detailed Description
BACKGROUND: The Holmium:Yttrium-Aluminium-Garnet (Ho:YAG) has been considered the gold-standard laser for ureteroscopy (URS) because of its versatility, with the ability to break all kinds of stones in the urinary tract as well as tumor- and soft tissue ablation. Development of higher power laser technology has allowed the limits of what can be achieved with URS to be set even higher. In comparison to stone fragmentation, techniques such as dusting and pop-corning often implement higher power settings (>20 Watts), and the efficacy associated with different strategies has been the focus of many studies. Intraoperative safety of URS has gained increased attention, particularly with regard to raised temperature levels. Recently, a new Thulium Fiber Laser (TFL) has been introduced. With the advent of the TFL, discussion surrounding high temperatures during lithotripsy and resultant thermal damage have been fueled further. Defining safe margins for laser settings is especially important for the TFL as no consensus exists for what is acceptable during URS. To date, there are no clinical studies investigating intrarenal temperatures during URS laser treatment. Studying temperature profiles during URS laser activation in patients is therefore of critical importance and highly clinically relevant to define the safety of different laser settings and power.
AIMS OF THE STUDY: The primary aim of this study is to investigate the temperature profiles in the renal pelvis during TFL laser activation using different settings. To this end, comparison of peak temperatures during laser activation for different settings is the main aim. Secondary aim is trying to define the duration of safe laser activation until the threshold for heat induced cell injury (43oC) is reach.
THE URETEROSCOPIC PROCEDURE AND TEMPERATURE MEASUREMENTS: The URS procedure is performed in general anaesthesia and all patients will have prophylactic antibiotics prior to surgery start, either according to urine culture or current local regime.
The procedure starts with a cystoscopy followed by semirigid URS when considered appropriate. Balloon dilatation is performed on demand. When reaching the stone, this is flushed back into the renal pelvis for disintegration there if possible. In cases where the stone cannot be flushed back into the renal pelvis, the stone is disintegrated in situ before the endoscope is advanced up to the renal pelvis for temperature measurements. Before laser disintegration, the semirigid ureteroscope is changed for a flexible ureteroscope that is advanced to the renal pelvis directly or over a guide wire that must be removed as soon as the endoscope is in place. An access sheath cannot be used during this study. Room-tempered (23oC), gravitational irrigation fluid at 60 cm height is used throughout the procedure. Manual pumping should be avoided and should in any case not be performed during the temperature measurements.
Under endoscopic vision, a sterilized thermocouple sensor (K-type, same as in the pre-clinical study) is introduced through the nephrostomy tube so that the tip can identified through the side-holes of the nephrostomy tube. The stone is moved to the central renal pelvis for laser disintegration, and a 150μm laser fiber is introduced into the renal pelvis through the working channel of the flexible ureteroscope. At this point the nephrostomy tube is clamped to achieve filling of the renal pelvis and to mimic a normal procedure.
Laser disintegration of the stone is started using the lowest laser setting of 5 Watts continuously for 120 seconds followed by 60 seconds of idling laser. Temperature measurements are maintained continuously during these 180 seconds, with two measurements per second. When the temperature in the renal pelvis has reached base temperature after one series of measurements, the procedure is repeated for the next laser setting. In total, URS lithotripsy are performed for three different settings. If 43oC is reach during laser activation for any of the laser settings, the laser will be stopped immediately and further laser activation with that specific settings will be aborted. Laser activation with subsequent settings will be ready when base temperature is reached.
If stone treatment is not completed at the end of the three series of laser activation and temperature measurements, further stone disintegration will be performed before finishing the URS procedure.
A double J-stent is placed at the end if deemed necessary by the surgeon. The nephrostomy tube is removed when considered appropriate. If a double J-stent is placed after the procedure, this is removed according to standard routine after 1-2 weeks in the outpatient clinic.
FOLLOW-UP: Follow-up with CT is performed at 3 months post endoscopically for all patients to assess stone free status and exclude a ureteral stricture in addition to a clinical consultation.
LASER SETTINGS: The following laser settings will be used in the study:
5 watts of power: 0.5 Joules (J) / 10 Herz (Hz), short pulse 10 watts of power: 0.5 J / 20 Hz, short pulse 20 watts of power: 0.5 J / 40 Hz, short pulse 30 watts of power: 1 J / 30 Hz, short pulse
ETHICAL CONSIDERATION AND APPROVALS: Participation in the study is voluntarily, and the patient can choose to withdraw at any point during the study process. Inclusion in the study will only be done after the consent form is signed.
The study is approved by The National Committees for Research Ethics in Norway (REK-550816). Application for approval by The Data Protection Authorities at Haukeland University Hospital has been sent.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: Øyvind Ulvik, Assoc Prof
- Phone Number: +47 90918595
- Email: doc.ulvik@online.no
Study Contact Backup
- Name: Mathias S Æsøy, MD
- Email: mathias.asoy@gmail.com
Study Locations
-
-
Vestland
-
Bergen, Vestland, Norway, 5021
- Haukeland University Hospital
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients ≥ 18 years with a ureteral stone (with or without a concomitant renal stone) and an indwelling nephrostomy tube scheduled for URS lithotripsy at the Day Surgery unit at Haukeland University Hospital
Exclusion Criteria:
- Urinary diversion
- Active infection
- Untreated cancer in the upper urinary tract
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
---|---|
Experimental: Temperature measurement group
Temperature measurement in the renal pelvis during ureteroscopic laser stone disintegration.
Temperature measurement will be performed using different laser power settings.
|
Temperature measurement in the renal pelvis during ureteroscopic laser activation.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
Temperature profiles
Time Frame: During surgery
|
Temperatures during ureteroscopic laser activation using different laser power settings.
|
During surgery
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Øyvind Ulvik, Assoc Prof, Haukeland University Hospital
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 550816
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Ureteral Stone
-
IRCCS San RaffaeleRecruitingKidney Stone | Ureteral StoneItaly
-
University Hospital, AngersNot yet recruitingRenal Stone | Ureteral Stone
-
Olympus Corporation of the AmericasCompletedKidney Stone | Ureteral StoneUnited States, Portugal, Denmark
-
Indiana Kidney Stone InstituteUniversity of Washington; VA Puget Sound Health Care SystemCompleted
-
Northwestern UniversityRecruitingKidney Stone | Ureteral StoneUnited States
-
Mohammad Sadegh Bagheri BaghdashtCompletedUreter StoneIran, Islamic Republic of
-
Adva-TecUniversity of British ColumbiaCompletedUnilateral Ureteral Stone | Renal Stone Fragments ≤ 2mmCanada
-
United States Naval Medical Center, San DiegoUnknown
-
Hamad Medical CorporationRecruitingUreteric Stone | Stone UreterQatar
-
University of British ColumbiaPercutaneous Systems, Inc.Completed
Clinical Trials on Temperature measurement
-
Ankara City Hospital BilkentCompletedHypothermia | Orthopedic Disorder | Hip ArthropathyTurkey
-
Accademia Italiana Medicina OsteopaticaRecruiting
-
Rambam Health Care CampusUnknownto Evaluate the Performance of the TMS Thermometer and | Improve Its AlgorithmIsrael
-
Institute of Mountain Emergency MedicineNot yet recruitingEmergencies | Hypothermia
-
University of OklahomaCompleted
-
Duke UniversityCompletedBreast ReconstructionUnited States
-
University of OklahomaRecruitingCrohn Disease | Colitis | Graft Vs Host DiseaseUnited States
-
Marmara UniversityCompletedHypothermia; Anesthesia | Hypothermia Following AnesthesiaTurkey
-
Marmara UniversityCompletedHypothermia; Anesthesia | Hypothermia Following AnesthesiaTurkey