Safety and Efficacy of the QBX Peripheral Balloon Expandable Stent System in Peripheral Artery Disease (PAD) (QBX-RADAR)

QBX (5F/6F) Peripheral Balloon Expandable Stent System for the Treatment of Peripheral Artery Disease (PAD): Assessing Safety and Clinical Performance up to 12-months Follow-up

This study aims to evaluate the safety and performance of the QBX stent system in the treatment of PAD by reporting of peri- and postoperative complications, including major adverse vascular events (MAVE), Vascular Access Site Complications (VASCs) and bleeding at puncture site, and by evaluating the prevalence of Target Vessel Revascularization (TVR), amputations, procedural success, device performance, reduction in percentage diameter stenosis post-procedure compared to pre-procedure, artery patency, return to normal activity, Rutherford and Fontaine classification, quality of life (QoL), Ankle Brachial Index (ABI), and hospital- and patient-related costs in a prospectively maintained database.

Study Overview

Status

Not yet recruiting

Study Type

Observational

Enrollment (Anticipated)

100

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

      • Brussels, Belgium, 1040/1050
        • HIS IZZ
        • Contact:
          • Gregory Callebaut, Dr.
    • Limburg
      • Genk, Limburg, Belgium, 3600
        • Ziekenhuis Oost-Limburg Genk
        • Contact:
          • Wouter Lansink, Dr.
      • Hasselt, Limburg, Belgium, 3500
        • Jessa Ziekenhuis
        • Contact:
          • Bert Du Pont, Dr.
    • West-Vlaanderen
      • Kortrijk, West-Vlaanderen, Belgium, 8500
        • Az Groeninge
        • Contact:
          • Philip Lerut, Dr.

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

Patients with PAD which are indicated to receive treatment with the QBX balloon-expandable stent and 5/6-French system through a femoral access with the aim to improve the vessel lumen diameter of target lesions (de novo and re-stenoses) in native peripheral arteries, e.g. external iliac artery (EIA), internal iliac artery (IIA), common iliac artery (CIA), superficial femoral artery (SFA) and deep femoral artery (DFA).

Description

Inclusion Criteria:

  • Patient eligible for implantation of a peripheral balloon-expandable stent.
  • Target lesion is an occlusion or diameter stenosis is ≥50% by visual estimate.
  • Target lesion is a de novo or restenotic lesion.
  • Target lesion is located in the external iliac artery (EIA), internal iliac artery (IIA), common iliac artery (CIA), superficial femoral artery (SFA) and/or deep femoral artery (DFA). Bilateral treatment of the target lesions is allowed. There are no restrictions on the number of target lesions treated with QBX or the number of stents used. Kissing stents and overlapping stents are allowed to treat the target lesions.
  • Patient suffers from mild to intermittent claudication (Rutherford 1-3) or critical limb ischemia (Rutherford 4-5).
  • Patients with TASC A, B, C and D lesions.
  • Patient ≥ 18 years of age at study entry.
  • Patient and investigator signed and dated the informed consent form prior to the index-procedure.

Exclusion Criteria:

  • Age < 18 y.
  • Pregnant women, women who are currently breastfeeding, women of childbearing potential who are not using an effective method of contraception, or women planning to become pregnant during the course of the study.
  • Patients with Rutherford 0 and 6.
  • Patient received a different stent device than the study device for the target lesion.
  • Target lesion cannot be crossed with a guidewire (e.g. heavily calcified or excessively tortuous target lesion).
  • Reference vessel diameter is not suitable for the available stent design.
  • Target lesion was previously treated with a stent.
  • Target lesion is in a prosthetic vascular bypass graft or within 1 cm of a graft anastomosis.
  • Presence of significant stenosis (≥50%) or occlusion of inflow tract not successfully treated before or during the index-procedure (success is measured as < 30% residual stenosis and absence of distal embolization).
  • Outflow: In case of treatment of iliac arteries: Inadequate distal runoff with > 50% stenosis of either the common femoral artery or both the superficial and deep femoral arteries. In case of treatment of the SFA: Absence of at least one patent runoff vessel with ≤ 50% stenosis throughout its course (i.e., confirmed in-line patency to the level of the foot). Outflow can be treated before or during the index-procedure (success is measured as < 30% residual stenosis and absence of distal embolization).
  • Presence of active inflammation at the planned access site.
  • Use of alternative therapy (e.g. atherectomy, cutting balloon, laser, radiation therapy) as part of the index-procedure.
  • Patients in severe renal failure (estimated Glomerular filtration rate (eGFR) < 25 mL/min/1.73m). Lab results are maximum 30 days old.
  • Patient has a persistent acute intraluminal thrombus of the target lesion.
  • Target lesion is in an aneurysm or associated with an aneurysm in the vessel segment either proximal or distal to the target lesion.
  • Patient has an abdominal aortic aneurysm contiguous with an iliac artery target lesion.
  • Patient suffers from acute limb ischemia defined as any sudden decrease in limb perfusion causing a potential threat to limb viability.
  • Contraindication for anti-coagulation therapy (coagulopathy, etc.).
  • Patient has a known intolerance to contrast agents. If hypersensitivity to contrast agents in patients with prior reactions could be improved by premedication and changing the contrast agent, the patient can be included in the study.
  • Patients has a known hypersensitivity to the stent material (L605).
  • Patient has a life expectancy of <12 months.
  • Patient has a planned surgical intervention/procedure, interfering with the study (results), within 30 days of the study procedure.
  • Patient is considered to be hemodynamically unstable at onset of index-procedure.
  • Patient is currently participating in a confounding study.
  • Patient is unable to comply with the protocol or proposed follow-up visits.
  • Patient is unable / unwilling to provide informed consent.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
QBX (5F/6F) Peripheral Balloon Expandable Stent System

The QBX Stent System is a flexible, balloon expandable stent, made of a cobalt chromium alloy manufactured by QualiMed Innovative Medizinprodukte GmbH. The design is suitable for peripheral vessel diameters from 5 to 10 mm.

The QBX Stent System is available as 6F and 5F variations where the 6F system is mounted on an 0.035" over-the-wire delivery system, and the 5F is mounted on an 0.018" over-the-wire delivery system. Both are available in a full range of diameters and lengths.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
To evaluate the cumulative rate of MAVE.
Time Frame: 12-months follow-up

MAVE is defined as:

  1. Device- or procedure-related death;
  2. Target Lesion Revascularization (TLR) at 12 months, defined as a repeated procedure (endovascular or open surgery) due to a problem arising from the lesion (+1 cm proximally and distally to include edge phenomena) initially treated;
  3. Device-related distal embolization that required hospitalization and/or subsequent intervention.
12-months follow-up

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Rate of subjects with Vascular Access Site Complications (VASCs) within the first 24h after the index-procedure
Time Frame: 24 hours

VASCs are defined as:

  • Hematoma/bleeding requiring transfusion
  • Arterial/venous occlusion/thrombosis
  • Severe vasospasm
  • Intimal injury/dissection
  • Pseudoaneurysm
  • Arteriovenous fistula
  • Vascular perforation or rupture
  • Arterial embolization distal to treatment site
  • Neuropathy
  • Retroperitoneal hematoma
24 hours
Intra-operative complication rate.
Time Frame: Index-procedure
Index-procedure
Post-operative complication rate.
Time Frame: 12-months follow-up
12-months follow-up
Intra-operative absence of bleeding at puncture site.
Time Frame: Index-procedure
Index-procedure
Re-occlusion rate.
Time Frame: 12-months follow-up
Re-occlusion is defined as complete occlusion of the target lesion initially treated.
12-months follow-up
Target Vessel Revascularization (TVR) rate.
Time Frame: 12-months follow-up
TVR is defined as a procedure (endovascular or open surgical) due to a problem arising in the target vessel remote from the target lesion(s) initially treated.
12-months follow-up
Amputation rate
Time Frame: 12-months follow-up
Minor (below the ankle) and major (above the ankle) amputation rate at 12 months will be assessed. Major amputation rates must be reported as below-the-knee and above-the-knee amputations.
12-months follow-up
Procedural success.
Time Frame: Index-procedure
Procedural success is defined as a combination of technical success, device success and absence of procedural complications.
Index-procedure
Technical success
Time Frame: Index-procedure
Technical success is defined as successful vascular access and completion of the endovascular procedure and immediate morphological success with less than 30% residual diameter reduction of the treated lesion on completion angiography.
Index-procedure
Device success.
Time Frame: Index-procedure
Device success is defined as exact deployment of the device according to the instructions for use.
Index-procedure
Device performance.
Time Frame: Index-procedure

Scored using the following components and a dedicated Scoring System (1: Very good, 2: Good, 3: Sufficient, Poor: 4):

  • Insertion through introducer sheath
  • Tracking to target site over guidewire
  • Crossability through of the lesion
  • Catheter pushability
  • Catheter shaft kink resistance
  • Stent radiopacity
  • Inflation time to Nominal diameter
  • Deflation time
  • Stent apposition
  • General usability of the QBX device
Index-procedure
Reduction in percentage diameter stenosis post-procedure compared to pre-procedure.
Time Frame: Index-procedure
Assessed via CT angio.
Index-procedure
Artery patency.
Time Frame: 1-month follow-up
A duplex ultrasound will be performed to evaluate artery patency. If reliable duplex ultrasound assessment of artery patency is not possible, ABI is a good indication of patency. If ABI is abnormal and the patient is experiencing symptoms, a CT angio or other imaging module might be performed according to standard of care.
1-month follow-up
Artery patency.
Time Frame: 6-months follow-up
A duplex ultrasound will be performed to evaluate artery patency. If reliable duplex ultrasound assessment of artery patency is not possible, ABI is a good indication of patency. If ABI is abnormal and the patient is experiencing symptoms, a CT angio or other imaging module might be performed according to standard of care.
6-months follow-up
Artery patency.
Time Frame: 12-months follow-up
A duplex ultrasound will be performed to evaluate artery patency. If reliable duplex ultrasound assessment of artery patency is not possible, ABI is a good indication of patency. If ABI is abnormal and the patient is experiencing symptoms, a CT angio or other imaging module might be performed according to standard of care.
12-months follow-up
Return to normal activity.
Time Frame: 1-month follow-up
The number of days until return to normal activities will be assessed.
1-month follow-up
Distribution of Rutherford classes during follow-up as compared to baseline.
Time Frame: 1-month follow-up
The percentage of patients with Rutherford classes 0 to 6 will be determined.
1-month follow-up
Distribution of Rutherford classes during follow-up as compared to baseline.
Time Frame: 6-months follow-up
The percentage of patients with Rutherford classes 0 to 6 will be determined.
6-months follow-up
Distribution of Rutherford classes during follow-up as compared to baseline.
Time Frame: 12-months follow-up
The percentage of patients with Rutherford classes 0 to 6 will be determined.
12-months follow-up
Distribution of Fontaine stages during follow-up as compared to baseline.
Time Frame: 1-month follow-up
The percentage of patients with Fontaine stages I to IV will be determined.
1-month follow-up
Distribution of Fontaine stages during follow-up as compared to baseline.
Time Frame: 6-months follow-up
The percentage of patients with Fontaine stages I to IV will be determined.
6-months follow-up
Distribution of Fontaine stages during follow-up as compared to baseline.
Time Frame: 12-months follow-up
The percentage of patients with Fontaine stages I to IV will be determined.
12-months follow-up
Primary sustained clinical improvement at 12 months.
Time Frame: 12-months follow-up
Primary sustained clinical improvement is defined as sustained upward shift of at least one category on the Rutherford/Fontaine classification without the need for repeated TLR in surviving patients.
12-months follow-up
Secondary sustained clinical improvement at 12 months.
Time Frame: 12-months follow-up
Secondary sustained clinical improvement is defined as sustained upward shift of at least one category on the Rutherford/Fontaine classification including the need for repeated TLR in surviving patients.
12-months follow-up
Improvement in disease-related health status, functioning and quality of life at follow-up as compared to baseline.
Time Frame: 1-month follow-up
This is scored by the Walking Impairment Questionnaire and EQ-5D questionnaire.
1-month follow-up
Improvement in disease-related health status, functioning and quality of life at follow-up as compared to baseline.
Time Frame: 6-months follow-up
This is scored by the Walking Impairment Questionnaire and EQ-5D questionnaire.
6-months follow-up
Improvement in disease-related health status, functioning and quality of life at follow-up as compared to baseline.
Time Frame: 12-months follow-up
This is scored by the Walking Impairment Questionnaire and EQ-5D questionnaire.
12-months follow-up
Ankle Brachial Index (ABI) during follow-up as compared to baseline.
Time Frame: 1-month follow-up
1-month follow-up
Ankle Brachial Index (ABI) during follow-up as compared to baseline.
Time Frame: 6-months follow-up
6-months follow-up
Ankle Brachial Index (ABI) during follow-up as compared to baseline.
Time Frame: 12-months follow-up
12-months follow-up
Occurrence of prolonged hospitalization compared to local standard of care (SOC).
Time Frame: Immediately after the procedure
When the patient leaves the hospital after the procedure.
Immediately after the procedure
Time taken off from work for the procedure
Time Frame: 1-month follow-up

Consists of:

  • Initial sick leave after the surgery
  • Additional sick leave
  • Leave taken by friends/relatives for patient care
1-month follow-up

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Anticipated)

May 1, 2023

Primary Completion (Anticipated)

June 30, 2025

Study Completion (Anticipated)

July 31, 2025

Study Registration Dates

First Submitted

March 6, 2023

First Submitted That Met QC Criteria

April 4, 2023

First Posted (Actual)

April 5, 2023

Study Record Updates

Last Update Posted (Actual)

April 5, 2023

Last Update Submitted That Met QC Criteria

April 4, 2023

Last Verified

March 1, 2023

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Peripheral Arterial Disease

Clinical Trials on QBX (5F/6F) Peripheral Balloon Expandable Stent System

Subscribe