- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT06128876
CMR-AI and Outcomes in AS
Artificial Intelligence-based Risk Stratification and Mid-term Outcomes in Severe Aortic Stenosis: Insights from Cardiac Magnetic Resonance Imaging
Background & Aims: Artificial Intelligence (AI) in cardiac magnetic resonance (CMR) imaging has previously been shown to provide highly reproducible and accurate measures of myocardial structure and function, outperforming clinical experts. The prognostic value of more sensitive markers of early left (LV) and right ventricular (RV) function, such as global longitudinal shortening (GLS), mitral annular plane systolic excursion (MAPSE), and tricuspid annular plane systolic excursion (TAPSE) has not been established due to the lack of automated analysis. Thus, our aim is to evaluate whether AI-based measurements of these early markers of adverse cardiac remodeling convey relevant prognostic information in patients with severe aortic stenosis (AS) beyond LV and RV ejection fraction (EF).
Materials & Methods: In a current large-scale international, prospective, multi-center study ~1500 patients with severe AS underwent CMR imaging prior to aortic valve replacement (AVR). An AI-based algorithm, developed in the UK, was used for fully automated assessment of parameters of cardiac structure (end-diastolic volume, end-systolic volume, LV mass, maximum wall thickness) and function (EF, GLS, MAPSE, TAPSE). In this proposed follow-up project, we aim to associate these AI-based CMR parameters at baseline with mid-term clinical outcomes at 24-months post-AVR. A composite of all-cause mortality and heart failure hospitalization will serve as the primary endpoint. CMR-AI will be repeated at 24-months follow-up and trajectories from pre- to post-AVR will be assessed as a secondary endpoint.
Future Outlook: In severe AS, a novel AI-based algorithm allows immediate and precise measurements of ventricular structure and function on CMR imaging. Our goal is to identify early markers of cardiac dysfunction indicating adverse mid-term prognosis post-AVR. This has guideline-forming potential as the optimal timepoint for AVR in patients with AS is currently a matter of debate.
Study Overview
Status
Conditions
Detailed Description
Artificial Intelligence (AI) and Machine Learning are reshaping our daily clinical practice, which has the potential to be more efficient, precise, and personalized. Adopting these technologies in cardiac imaging does not only affect decision making by improved accuracy and risk stratification but also significantly reduces scan times and post-imaging workup.
Current guidelines acknowledge cardiac magnetic resonance (CMR) imaging as gold standard for assessment of myocardial structure and function. Despite the fundamental importance in various cardiac diseases, measurements of size, mass, and ejection fraction (EF) are flawed by the inherent variability and subjectivity of human analysis. Recent developments in deep learning using convolutional neural networks (CNNs) allow for automated segmentation of the ventricular blood pool and myocardium using pre-existing CMR datasets. Importantly, these tools are integrated into CMR scanners generating real-time measurements without the need of time-consuming image post-processing. AI-based models have previously shown similar to superior precision in ventricular contouring, volumetry, and maximum wall thickness (MWT) measurements, outperforming clinical experts.
In patients with aortic stenosis (AS), changes in EF more often occur late in the disease process, whereas longitudinal shortening represents an earlier and more sensitive marker of left ventricular (LV) dysfunction. However, these CMR measurements are subjective, time-consuming, and therefore not routinely performed due to the lack of automated analysis. Recently, AI-measured global longitudinal shortening (GLS) and mitral annular plane systolic excursion (MAPSE) have been demonstrated to provide more reproducible and accurate results compared to human experts. We hypothesize that AI-based GLS and MAPSE could convey important prognostic information beyond LVEF in severe AS and represent early markers of adverse cardiac remodeling and outcome following aortic valve replacement (AVR). Furthermore, in our own working group, we could demonstrate that right ventricular (RV) dysfunction on CMR, rather than conventional parameters assessed by echocardiography, was independently associated with outcome in individuals with AS undergoing transcatheter aortic valve implantation. We aim to extend on our findings and investigate whether AI-based RV GLS and tricuspid annular plane systolic excursion (TAPSE) represent early markers of RV dysfunction indicating adverse prognosis.
Finally, the assessment of reverse cardiac remodeling by CMR requires reproducibility. AI has been proven to outperform humans in both precision and accuracy, and therefore has great potential for the comprehensive evaluation of longitudinal structural changes in AS following AVR. We aim to analyze mid-term reverse cardiac remodeling in patients with AS using novel AI technology.
Aims
With significant previous contributions in cardiac imaging and valvular heart disease being made by our research group, we aim to provide automated, precise, and time-saving algorithms to identify patients at risk post-AVR by addressing the following:
- Association of AI-measured LV and RV structural and functional markers on CMR prior to AVR with mid-term clinical outcomes at 24-months following AVR.
- Reverse cardiac remodeling, as determined by CMR-AI parameters, at baseline versus 24-months after AVR.
Methods
This project is designed as a large-scale international, prospective, multi-center, longitudinal-observational cohort study aimed at identifying predictors of structural and functional recovery in patients with severe AS undergoing clinically indicated AVR. Participants were previously enrolled from seven university-affiliated tertiary care centers in Continental Europe, the UK, and Asia between January 2020 and August 2024.
Baseline evaluation consisted of comprehensive pre-operative cardiac phenotyping including quality of life assessment, blood tests, electrocardiogram (ECG), and imaging (CMR and echocardiography). For this proposed project, reverse cardiac remodeling and mid-term clinical outcomes will be evaluated 24-months post-AVR through repeat baseline investigations.
Study Type
Enrollment (Estimated)
Contacts and Locations
Study Locations
-
-
-
Vienna, Austria
- Medical University of Vienna
-
-
-
-
-
Brussels, Belgium
- Université Catholique de Louvain
-
-
-
-
-
Goettingen, Germany
- University of Goettingen Medical Center
-
-
-
-
-
Seoul, Korea, Republic of
- Samsung Medical Center
-
Seoul, Korea, Republic of
- Seoul National University College
-
-
-
-
-
Vilnius, Lithuania
- Vilnius University
-
-
-
-
-
London, United Kingdom
- Barts Heart Centre
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Written informed consent
- Severe AS scheduled for Heart Team decision
Exclusion Criteria:
- Inability or unwillingness to perform any of the diagnostic tests
- Inability or unwillingness to participate in follow-up visits
- Metal implants, e.g. cochlear implants and pacemakers
- Chronic kidney failure (GFR < 30 ml/min/1.73m2)
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of patients with AI-measured parameters of impaired left and right ventricular structure and function on cardiac magnetic resonance imaging and association with the composite of all-cause death and heart failure hospitalization.
Time Frame: 2 years
|
Association of AI-based parameters (end-diastolic volume [ml], end-systolic volume [ml], left ventricular mass [gram], maximum wall thickness [mm], ejection fraction [%], global longitudinal shortening [%], mitral/tricuspid annular plane systolic excursion [mm]) on cardiac magnetic resonance imaging with the composite of all-cause death and heart failure hospitalization. Captured clinical endpoints will include all-cause death, cardiovascular mortality, and heart failure hospitalization. Data will be ascertained by follow-up visits, state-wide electronic hospital charts, and phone calls. In addition, mortality data will be obtained via National Death Registries of the participating countries. |
2 years
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of patients with AI-measured parameters of impaired left and right ventricular structure and function on cardiac magnetic resonance imaging and association with components of the primary endpoint analyzed individually.
Time Frame: 2 years
|
Association of AI-based parameters (end-diastolic volume [ml], end-systolic volume [ml], left ventricular mass [gram], maximum wall thickness [mm], ejection fraction [%], global longitudinal shortening [%], mitral/tricuspid annular plane systolic excursion [mm]) on cardiac magnetic resonance imaging with components of the primary endpoint (all-cause death and heart failure hospitalization) analyzed individually. Captured clinical endpoints will include all-cause death, cardiovascular mortality, and heart failure hospitalization. Data will be ascertained by follow-up visits, state-wide electronic hospital charts, and phone calls. In addition, mortality data will be obtained via National Death Registries of the participating countries. |
2 years
|
|
Number of patients with AI-measured parameters of impaired left and right ventricular structure and function on cardiac magnetic resonance imaging and association with cardiovascular mortality.
Time Frame: 2 years
|
Association of AI-based parameters (end-diastolic volume [ml], end-systolic volume [ml], left ventricular mass [gram], maximum wall thickness [mm], ejection fraction [%], global longitudinal shortening [%], mitral/tricuspid annular plane systolic excursion [mm]) on cardiac magnetic resonance imaging with cardiovascular mortality. Captured clinical endpoints will include all-cause death, cardiovascular mortality, and heart failure hospitalization. Data will be ascertained by follow-up visits, state-wide electronic hospital charts, and phone calls. In addition, mortality data will be obtained via National Death Registries of the participating countries. |
2 years
|
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of patients with AI-measured parameters of impaired left and right ventricular structure and function on cardiac magnetic resonance imaging at baseline and changes at 2-year follow-up after aortic valve replacement (AVR).
Time Frame: 2 years
|
Longitudinal trajectories of AI-based parameters (end-diastolic volume [ml], end-systolic volume [ml], left ventricular mass [gram], maximum wall thickness [mm], ejection fraction [%], global longitudinal shortening [%], mitral/tricuspid annular plane systolic excursion [mm]) on cardiac magnetic resonance imaging from pre- to 2-year post-AVR. Captured clinical endpoints will include all-cause death, cardiovascular mortality, and heart failure hospitalization. Data will be ascertained by follow-up visits, state-wide electronic hospital charts, and phone calls. In addition, mortality data will be obtained via National Death Registries of the participating countries. CMR will be repeated at 2 year. |
2 years
|
Collaborators and Investigators
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Estimated)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- VIE_CMR-AI
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Aortic Stenosis
-
National Institute of Cardiology, Warsaw, PolandThe Institute of Bioorganic Chemistry, Polish Academy of SciencesRecruitingAortic Stenosis | Low-gradient Aortic StenosisPoland
-
MiRusRecruitingAortic Stenosis | Symptomatic Severe Native Aortic StenosisUnited States
-
Anteris Technologies Ltd.Active, not recruitingAortic Stenosis | Aortic Valve Calcification | Severe Aortic Valve Stenosis | Symptomatic Aortic StenosisUnited States
-
Edwards LifesciencesCompletedAortic Stenosis | Aortic Regurgitation | Symptomatic Aortic StenosisChina
-
Azienda Ospedaliera "Sant'Andrea"University of Bologna; Politecnico di Milano; Centro Cardiologico Monzino; I.R.C...RecruitingAortic Stenosis | Calcific Aortic Valve Disease | Chronic Coronary Syndrome | Calcific Aortic StenosisItaly
-
Hospices Civils de LyonCompleted
-
Abbott Medical DevicesCompletedSevere Aortic Stenosis | Symptomatic Degenerative Aortic StenosisSpain, Italy, United Kingdom, Germany, Switzerland, Czechia, Australia, Belgium, Poland
-
Edwards LifesciencesRecruitingAortic Valve Stenosis | Aortic Stenosis, CalcificUnited States, Australia, Switzerland, Canada, Japan, Netherlands
-
Rede Optimus Hospitalar SARecruitingSevere Aortic StenosisSwitzerland, France, Germany, Austria, Czechia, Italy, Netherlands
-
Medtronic CardiovascularActive, not recruitingSevere Aortic StenosisUnited States, Netherlands, Canada, Spain, Denmark, United Kingdom, Switzerland, Germany, Sweden