Innovative Technologies for Salvage Procedures of Failed Treatments of Osteoarthritis: Biomimetics Solutions (CustomPN) (CustomPN)

February 19, 2026 updated by: Istituto Ortopedico Rizzoli

Innovative Technologies for Cost-Effective Healthcare Delivery for Salvage Procedures of Failed Treatments of Osteoarthritis: Specific Biomimetics Solutions to Reduce a Growing Problem With a High Social and Economic Impact.(CustomPN)

In this prospective multicenter study, a population of adult individuals consecutively treated for revision hips, requiring a custom-made acetabular implant for non-oncological reasons, will be included. The custom-made implant is a personalized implant produced using additive manufacturing, based on the pre-operative CT scan that details the bone damage. Patients eligible for this implant are those with severe acetabular bone damage Paprosky 3 (loss of the superolateral part and one of the two ventro-caudal walls).

Preoperatively, the patient will undergo a clinical evaluation. Data will be collected on the patient's general health status with the Charlson score, the reason for revision, number of revisions, type of implant in place, and the time elapsed between the failed implant and the revision in question. The bone deficit will be studied through CT measurements according to qualitative and quantitative scales. During the surgery, information on intraoperative complications will be collected. In the postoperative period, perioperative complications will be collected according to the Clavien Dindo classification. The clinical radiographic evaluations will be carried out during outpatient follow-up visits at 1, 3, 12, 24, and 36 months after revision. They include the Harris Hip Score clinical score, the EQ-5D PROM, and the patient's satisfaction level (qualitative assessment in 4 grades: unsatisfied, slightly satisfied, moderately satisfied, fully satisfied). The positional parameters of the implant will be evaluated, as compared to the immediate post-operative X-ray: acetabular abduction, acetabular anteversion, center of rotation height, center of rotation medialization, and inclination of the custom-made component. From 12 months onwards, the osteointegration characteristics of the component will be assessed: presence of radial trabeculae at the interface, superolateral and inferior reinforcements, stress shielding, absence of radiolucent lines. Re-revision rates will be determined using the Kaplan-Meier method. The reasons for re-revision will be noted.

Study Overview

Detailed Description

Osteoarthritis (OA) increased from 247.51 million people in 1990 to 527,81 million in 2019. OA places a huge burden on healthcare services accounting for 1-2,5% of the gross national products and the cost is expected to quadruple by 2030. Total joint replacement (TJR) represents the standard of care of end-stage OA. TJR is projected to nearly double by 2026. Unfortunately, TJR are subject to failure, thus the number of revision procedures is also growing, accounting for 5-6% of all TJR. Failure of TJR represents a dramatic event for patients and National Health Systems. Patients suffer enormous disability, with impact on function, emotional sphere, and loss of autonomy. The average cost of treatment is almost doubled compared to TJR, and in case of periprosthetic joint infections almost tripled. In patients under 65 years (with a failure rate of 9%-12%), the full return to work is reported only in 7%-33% of the cases, and not earlier then 1 year after the surgery, while around 50% retired or remained on welfare benefits. Current technology is not enough to overcome this set of problems, while actual projections predict a 43%-70% increase in revisions by 2030. In particular, revision hips involve various diagnoses and settings: in some cases, the severe bone loss makes the reconstruction very complex. In these cases, acetabular reconstruction can be performed with off-the-shelf implants, but outcomes are not always consistent and reproducible. Thus, in cases of severe acetabular bone loss, it may be very useful to proceed with a customized implant, designed according to the patient's needs. Implants produced in this way are designed based on the patient's pre-operative CT scan using additive manufacturing technology. The purpose is to offer a personalized bone filling of the defect with a highly porous interface that promotes osteointegration. Currently, most of the custom-made implants are performed for oncological cases. On the contrary, there are few indications on the clinical and radiological outcomes of custom-made acetabular reconstructions in revision hips with severe bone loss in non-oncological cases. The purpose of this project is to validate an innovative and reliable technology (custom-made acetabular component produced using additive manufacturing) for managing non-oncological revisions, assessing short term outcomes.

The aims are:

Description of demographic characteristics and bone defect in candidates for acetabular reconstruction with custom-made implants Perioperative complications and implant survival Clinical evaluation of custom-made implants in custom-made acetabular reconstructions in hip prosthesis revisions with severe bone loss (clinical score Harris Hip Score; subjective score PROM EQ-5D; post-operative patient satisfaction level) Radiographic evaluation (positioning and osteointegration) of custom-made implants in custom-made acetabular reconstructions in hip prosthesis revisions with severe bone loss This is a prospective multicenter study. The study population will consist of adult individuals consecutively treated for revision hips, requiring a custom-made acetabular implant. Patients with a diagnosis leading to an oncological revision will not be included. The custom-made implant is a personalized implant created by an external company based on the pre-operative CT scan that details the bone damage. Patients eligible for this implant are those with severe acetabular bone damage Paprosky 3 (loss of the superolateral part and one of the two ventro-caudal walls). In these cases, off-the-shelf therapeutic options are limited and achieve uncertain outcomes: therefore, a custom-made component with ultra-porous anchoring surfaces can represent a highly advantageous therapeutic choice. After identifying the suitable patient and obtaining their consent for the study, a pre-operative CT scan will be performed as per normal clinical practice for every revision. After uploading it to the dedicated website or app of the company, this CT scan will be used for the manufacturing of the custom-made implant by a third-party company. The company will also provide plastic phantoms for preliminary study of the implant. Upon approval of the implant production, the company will manufacture the implant according to current regulations and production techniques, following previous and established clinical practice. The device will be accompanied by personalized instrumentation, such as cutting guides, positioners, calipers, and plastic simulation phantoms, to facilitate the surgical procedure. The implant and the produced instrumentation will be delivered to the reference center after performing the patient's surgical planning.

Preoperatively, the patient will undergo an evaluation with the Harris Hip score clinical score. Additionally, data will be collected on the patient's general health status with the Charlson score, the reason for revision, number of revisions, type of implant in place, and the time elapsed between the failed implant and the revision in question. The bone deficit will be studied through CT measurements according to qualitative and quantitative scales.

During the surgery, information on intraoperative complications will be collected. In the postoperative period, perioperative complications will be collected according to the Clavien Dindo classification. The clinical radiographic evaluations will be carried out during outpatient follow-up visits at 1, 3, 12, 24, and 36 months after revision. They include the Harris Hip Score clinical score, the EQ-5D PROM, and the patient's satisfaction level (qualitative assessment in 4 grades: unsatisfied, slightly satisfied, moderately satisfied, fully satisfied). The positional parameters of the implant will be evaluated, as compared to the immediate post-operative X-ray: acetabular abduction, acetabular anteversion, center of rotation height, center of rotation medialization, and inclination of the custom-made component. From 12 months onwards, the osteointegration characteristics of the component will be assessed: presence of radial trabeculae at the interface, superolateral and inferior reinforcements, stress shielding, absence of radiolucent lines. Re-revision rates will be determined using the Kaplan-Meier method. The reasons for re-revision will be noted.

Study Type

Observational

Enrollment (Estimated)

15

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

Study Locations

      • Bologna, Italy, 40136
        • Recruiting
        • Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
        • Contact:

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Sampling Method

Non-Probability Sample

Study Population

The study population will consist of adult individuals (minimum age: 18 years) consecutively treated for revision hips (non-oncological reasons) requiring a custom-made acetabular implant. Patients will be enrolled in 4 tertiary centers (multicenter prospective study). Patients eligible for this implant are those with severe acetabular bone damage Paprosky 3 (loss of the superolateral part and one of the two ventro-caudal walls).

Description

Inclusion Criteria:

  • need of custom-made acetabular implant on the basis of CT and X-ray evaluation ()
  • pre-operative CT scan
  • adults patients (minimum age: 18 years)
  • complete medical charts
  • patients' availability

Exclusion Criteria:

  • oncological reasons for revision
  • other types of revision implant (non custom)
  • inadequate medical chart
  • lack of pre-operative CT scan

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Custom-made
Revision hip arthroplasty performed for non-oncological reasons, with Paprosky III bone loss
custom-made acetabular implant produced with additive manufacturing, to fill the bony loss in Paprosky III bone defects

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Perioperative complications
Time Frame: 0-30 days
Clavien-Dindo classification: 5 stages with IIIA and IIIB, IV A and IV B. I stage: minimal complications, V stage: death of the patient.
0-30 days
Objective clinical outcomes
Time Frame: 0-18 months
Harris Hip Score. Numerical scale assessing mobility, pain and functionality. Range: 0-100. 100 is the best objective outcome.
0-18 months
Subjective clinical outcomes
Time Frame: 0-18 months
EQ-5D-5L. Subjective score with 5 dimensions: mobility, self-care, pain, usual activity, anxiety/depression (5 levels per each assessment). Weighted index on a 0-1 scale. Best outcome: 1
0-18 months
Subjective clinical outcomes (satisfaction)
Time Frame: 0-18 months
Percentage of satisfied patients per single level. 4 levels, from not satisfied to completely satisfied.
0-18 months
Survival rates
Time Frame: 0-18 months
Survival rates using Kaplan Meier curve. Range: 0-100%. Best outcome: 100%
0-18 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Osseointegration of the acetabular component
Time Frame: 12-18 months
Percentages of cases with good osseointegration of the acetabular component according to Moore's criteria. At least three criteria among: presence of radial trabeculae at the interface, presence of superolateral buttress, presence of inferior buttress, presence of medial stress shielding, absence of radiolucent lines. Range: 0-100%. Best outcome: 100%
12-18 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Francesco Traina, Prof, IRCCS Istituto Ortopedico Rizzoli

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

October 1, 2024

Primary Completion (Estimated)

March 30, 2026

Study Completion (Estimated)

September 30, 2026

Study Registration Dates

First Submitted

July 23, 2024

First Submitted That Met QC Criteria

July 25, 2024

First Posted (Actual)

July 30, 2024

Study Record Updates

Last Update Posted (Actual)

February 23, 2026

Last Update Submitted That Met QC Criteria

February 19, 2026

Last Verified

February 1, 2026

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Bone Loss

Clinical Trials on custom-made acetabular implant

Subscribe